BAXI COMBI 130 HE
WARNING - IMPORTA
OVERRUN/ANTICYCLE
MAINS POWER ON
SE
DHW FAN RUNS
CENTRAL HEATING DEMAND OFF
HOW TO SET THE MULTIMETER TO DIODE CHECK
THE IMAGES BELOW SHO
FAULT 1
KIT - HARNESS MV
FAULT1
MAINS FUSE
FAULT 1
FILTER - ELECTRICAL
FAULT 1
FUSE F1
FAULT 1 CHOKED
DHW INLET FILTER
FAULT 1 DHW DEMAND
KIT - SWITCH - ADAPTOR FLOW - DHW
FAULT 1
THERMISTOR - FLOW TEMP RED
FAULT 1
THERMISTOR - FLOW TEMP - RED
FAULT 1
THERMOSTST - OVERHEAT
FAULT 1
THERMOSTAT - OVERHEAT
FAULT 1
CONDENSATE TRAP AND DRAIN
FAULT 1
CONDENSE SENSE LEAD
FAULT 1 CHOKED
FLOW REGULATOR DHW
FAULT 1
KIT - SENSING ELECTRODE
FAULT 1
HEAT EXCHANGER GAS TO WATER FLUE WAYS
FAULT 1
FLUE
FAULT 1
PIPE 5 MM NEOPRENE
FAULT 1 CLEAN AS NEC
VENTURI
FAULT 1
EXPANSION VESSEL
FAULT 1
DIVERTER VALVE SPINDLE
FAULT 14 DV DRIVE FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 2
PUMP
FAULT 2
THERMISTOR - FLOW TEMP RED
FAULT 2
THERMISTOR - FLOW TEMP - RED
FAULT 3
FAN
FAULT 15 FAN DRIVE FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 2
CONDENSATE TRAP AND DRAIN
FAULT 3
THERMISTOR - FLOW TEMP RED
FAULT 3
THERMISTOR - FLOW TEMP - RED
FAULT 3
PUMP
FAULT 2
DIVERTER VALVE SPINDLE
FAULT 5
PUMP
FAULT 02 LOW VOLTS FAULT
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 4
THERMISTOR - FLOW TEMP - RED
FAULT 1 RESET OR REPLACE
APPLIANCE TEMPERATURE SETTING
FAULT 5
THERMISTOR - FLOW TEMP - RED
FAULT 3
CONDENSATE TRAP AND DRAIN
FAULT 4
THERMISTOR - FLOW TEMP RED
FAULT 6
THERMISTOR - FLOW TEMP - RED
FAULT 21 OVERRUN/ANTICYCLE FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 1
CH FILTER
FAULT 2
CH FILTER
FAULT 2 PREHEAT SETTING
DISPLAY PCB
FAULT 3
CH FILTER
FAULT 05 DHW DEMAND FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 03 FAN FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 1
PCB - FAN DRIVER
FAULT 1
HARNESS - LOW VOLTAGE
FAULT 1
VALVE BODY
FAULT 09 DV FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
BACKED UP
CONDENSATE TRAP AND DRAIN
WATER INGRESS PREVENTING VALVE OPENING
PIPE 5 MM NEOPRENE
FAULT 12 GAS VALVE FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 2
FAN
FAULT 1
PIPE - BURNER FEED
NOT IGNITING
FLUE
RESTRICTED OR BLOCKED
PIPE 5 MM NEOPRENE
BACKED UP 2
CONDENSATE TRAP AND DRAIN
BURNER DOES NOT IGNITE
KIT - ELECTRODE
FAULT 1 REPAIR OR REPLACE
BURNER
DOES NOT IGNITE
KIT - ELECTRODE (NO WIRES)
OPEN CIRCUIT OR HIGH RESISTANCE
LEAD - ELECTRODE
GAS VALVE HARNESS
KIT - HARNESS MV
BLANK FOR DIODE TEST
Z DIRECTION CHOICE OR CONTINUE
FAULT 13 EXTERNAL CONTROL SUPPLY
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT
KIT - HARNESSS MV
FAULT 1
TIMER/LINK
FAULT 08 CH DEMAND FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
STUCK MADE
KIT - SWITCH - ADAPTOR FLOW - DHW
RESTRICTED OR BLOCKED
VENTURI
FAULT 1
PUMP
FAULT 1
TRANSFORMER
FAULT 01 MAINS INPUT
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 1 PARTIALY CLOSED
VALVE - ANGLED - WATER
FAULT 06 LOW VOLT SU
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 04 PUMP FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 11 CONDENSE SENSE
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 10 FLAME RECTIFICATION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 1
HARNESS - LOW VOLTAGE
FAULT 2 REPAIR OR REPLACE
BURNER
FAULT 2
VALVE BODY
FAULT 3
VALVE - PLASTIC - DIVERTER
FAULT 2
KIT - PLATE HEAT EXCHANGER
FAULT 2
PCB - FAN DRIVER
FAULT 3
KIT - PLATE HEAT EXCHANGER
FAULT 16 TEMP CALIBRATION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 3
VALVE BODY
FAULT 17 TEMP CALIBRATION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 19 TEMP CALIBRATION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 3 NO SET
DISPLAY PCB
FAULT 18 PREHEAT FUNCTION
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 1
HEAT EXCHANGER GAS TO WATER
FAULT1
HARNESS - LOW VOLTAGE
FAULT 2
HARNESS - LOW VOLTAGE
FAULT 1
FAN
INSUFFICIENT
GAS INLET PRESSURE
FAULT 1
FLOW SWITCH
FAULT 1
VALVE - PLASTIC - DIVERTER
FAULT 2 MECH
KIT - VALVE MULTIFUNCTIONAL
OPENING BUT WRONG MIX
KIT - VALVE MULTIFUNCTIONAL
NO SPARK
KIT - PCB ELECTRONIC CONTROL/DISPLAY
FAULT 1
TERMINAL LINK
FAULT
ROOM THERMOSTAT
FAULT1
KIT - HARNESS MV
FAULT 2
VALVE - PLASTIC - DIVERTER
FAULT 1
KIT - PLATE HEAT EXCHANGER
FAULT 1 NO DISPLAY
DISPLAY PCB
Burner stable BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM DHW BURNER ESTABLISH
Burner unstable
CHARACTERISTIC TEST FROM DHW BURNER ESTABLISH
DHW cold, radiators warm
CHARACTERISTIC TEST FROM DHW OPERATION
Noisy operation
CHARACTERISTIC TEST FROM DHW OPERATION
DHW cool, radiators cool
CHARACTERISTIC TEST FROM DHW OPERATION
Cycles hot and cold when used for long spells
CHARACTERISTIC TEST FROM DHW OPERATION
Boiler to temperature, radiators do not heat
CHARACTERISTIC TEST FROM CH OPERATION
Boiler noisy/kettling
CHARACTERISTIC TEST FROM CH OPERATION
Boiler temperature low, radiators temperature low
CHARACTERISTIC TEST FROM CH OPERATION
Boiler fires but cuts out before temperature is reached
CHARACTERISTIC TEST FROM CH OPERATION
Display board would not set
CHARACTERISTIC TEST FROM PREHEAT OPERATION
Display board set but no preheat
CHARACTERISTIC TEST FROM PREHEAT OPERATION
NO DROP IN THE STANDING PRESSURE OBSERVED
CHARACTERISTIC TEST FROM GAS USAGE
INLET PRESSURE DROPS BELOW 18MB
CHARACTERISTIC TEST FROM GAS USAGE
24/11/2017 09:55:48 1711_1_50_1 09/01/2018 08:44:39
27/11/2017 08:02:47
PUMP VOLTAGE
{ISOLATEMAINSPOWER}<
TRANSFORMER OUTPUT VOLTAGE
{ISOLATEMAINSPOWER}<
TRANSFORMER INPUT VOLTAGE
USE INSULATION MAT AS NECESSARY
MAINS POWER SUPPLY
{ISOLATEMAINSPOWER}<
MAINS POWER SUPPLY FUSE RESISTANCE
{ISOLATEMAINSPOWER}
REMOVE THE FUSE FROM THE APPLIANCE MAINS POWER SUPPLY I.E. FUSED SPUR
DHW INLET SERVICE VALVE
{ISOLATEMAINSPOWER}
DHW INLET FILTER
{ISOLATEMAINSPOWER}
DHW CIRCUIT OFF AND DRAINED
CONDENSE RESISTANCE TO EARTH
{ISOLATEMAINSPOWER}
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
FLAME SENSE ELECTRODE
{ISOLATEMAINSPOWER}
REMOVE FLAME SENSE ELECTRODE
LOW VOLTAGE OUTPUT
{ISOLATEMAINSPOWER}<
DIVERTER VALVE VOLTAGE (DHW)
{ISOLATEMAINSPOWER}<
FAN SPEED AND PRESSURE CHECK
{ISOLATEMAINSPOWER}<
DIVERTER VALVE SPINDLE
{ISOLATEMAINSPOWER}
REMOVE DIVERTER VALVE ACTUATOR HEAD TO EXPOSE THE DIVERTER VALVE SPINDLE
GAS USAGE
{ISOLATEMAINSPOWER}
ATTACH U GAUGE TO INLET PRESSURE TEST POINT
VOLTAGE TO FAN BOARD RED/BLUE
{ISOLATEMAINSPOWER}
USE INSULATION MAT AS NECESSARY
VOLTAGE FROM CONTROL BOARD RED/BLUE
USE INSULATION MAT AS NECESSARY
REMOVE THE MAIN CONTROL BOX COVER TO EXPOSE THE CONTROL PCB
VOLTAGE FROM CONTROL BOARD YELLOW/BLUE
USE INSULATION MAT AS NECESSARY
DIVERTER VALVE SPINDLE
{ISOLATEMAINSPOWER}
REMOVE DIVERTER VALVE ACTUATOR HEAD TO EXPOSE THE DIVERTER VALVE SPINDLE
ELECTRODES SPARK AND EARTH AND GAP
{ISOLATEMAINSPOWER}
REMOVE THE SPARK ELECTRODE ASSEMBLY
DHW FLOW SWITCH RESISTANCE
{ISOLATEMAINSPOWER}<
EXTERNAL CONTROL INPUT
USE INSULATION MAT AS NECESSARY
CONTROL VOLTAGE RTC OUTPUT
USE INSULATION MAT AS NECESSARY
CONTROL VOLTAGE RTC INPUT
USE INSULATION MAT AS NECESSARY
PUMP HARNESS
{ISOLATEMAINSPOWER}
FUSE F1
{ISOLATEMAINSPOWER}<
EMC FILTER
{ISOLATEMAINSPOWER}
DISCONNECT MAINS INPUT PLUG FROM REAR OF THE EMC FILTER
DHW FLOW REGULATOR
{ISOLATEMAINSPOWER}
DHW CIRCUIT OFF AND DRAINED
DHW FLOW SWITCH RESISTANCE
{ISOLATEMAINSPOWER}<
RETURN SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT BLUE LEADS FROM THE RETURN SENSOR
FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT RED LEADS FROM THE FLOW SENSOR
FLOW SENSOR RESISTANCE (OVERHEAT)
{ISOLATEMAINSPOWER}<
OVERHEAT SENSOR RESISTANCE (CASE)
{ISOLATEMAINSPOWER}<
CONDENSE LEAD INTEGRITY
{ISOLATEMAINSPOWER}
FLAME RECTIFICATION VOLTAGE
{ISOLATEMAINSPOWER}<
SENSING TUBE
{ISOLATEMAINSPOWER}
REMOVE SENSING TUBE FROM GAS VALVE
DISPLAY BOARD VOLTAGE
{ISOLATEMAINSPOWER}<
PRIMARY HEAT EXCHANGER FLUE WAYS
{ISOLATEMAINSPOWER}
FAN AIR INTAKE CHECK
{ISOLATEMAINSPOWER}
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
DIVERTER VALVE SPINDLE
{ISOLATEMAINSPOWER}
REMOVE DIVERTER VALVE ACTUATOR HEAD TO EXPOSE THE DIVERTER VALVE SPINDLE
RETURN SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT BLUE LEADS FROM THE RETURN SENSOR
FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT RED LEADS FROM THE FLOW SENSOR
FAN VOLTAGE (TEST 7)
{ISOLATEMAINSPOWER}<
RETURN SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT BLUE LEADS FROM THE RETURN SENSOR
FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT RED LEADS FROM THE FLOW SENSOR
FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT RED LEADS FROM THE FLOW SENSOR
FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT RED LEADS FROM THE FLOW SENSOR
CONDENSATE TRAP AND DRAIN
{ISOLATEMAINSPOWER}
FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT RED LEADS FROM THE FLOW SENSOR
RETURN SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT BLUE LEADS FROM THE RETURN SENSOR
CH FILTER CHECK
{ISOLATEMAINSPOWER}
CH ISOLATING VALVES OFF
BOILER DISCHARGED AND DRAINED
CH FILTER CHECK
{ISOLATEMAINSPOWER}
CH ISOLATING VALVES OFF
BOILER DISCHARGED AND DRAINED
CH FILTER CHECK
{ISOLATEMAINSPOWER}
CH ISOLATING VALVES OFF
BOILER DISCHARGED AND DRAINED
VOLTAGE TO FAN BOARD YELLOW/BLUE
USE INSULATION MAT AS NECESSARY
VOLTAGE TO FAN
{ISOLATEMAINSPOWER}
DISCONNECT FAN HARNESS FROM FAN
RESISTANCE FAN HARNESS
{ISOLATEMAINSPOWER}
DISCONNECT FAN HARNESS FROM FAN
PRIMARY FLOW SWITCH RESISTANCE
{ISOLATEMAINSPOWER}<
DIVERTER VALVE VOLTAGE (DHW)
{ISOLATEMAINSPOWER}<
SENSING TUBE
{ISOLATEMAINSPOWER}
REMOVE SENSING TUBE FROM GAS VALVE
GAS VALVE VOLTAGE
{ISOLATEMAINSPOWER}<
FAN SPEED AND PRESSURE CHECK
{ISOLATEMAINSPOWER}<
INJECTOR TUBE
{ISOLATEMAINSPOWER}
INSPECTION FAN ASSEMBLY AIR INTAKE
{ISOLATEMAINSPOWER}
SENSING TUBE
{ISOLATEMAINSPOWER}
REMOVE SENSING TUBE FROM GAS VALVE
OBSERVATION SPARKING AT ELECTRODE
{ISOLATEMAINSPOWER}<
BURNER
{ISOLATEMAINSPOWER}
REMOVE COMBUSTION COVER
RESISTANCE SPARK ELECTRODE (NO WIRES)
{ISOLATEMAINSPOWER}<
ELECTRODE LEADS
{ISOLATEMAINSPOWER}<
DIODE CHECK GAS VALVE HARNESS
{ISOLATEMAINSPOWER}<
EXTERNAL CONTROL OUTPUT
{ISOLATEMAINSPOWER}<
CONTROL VOLTAGE CLOCK INPUT
{ISOLATEMAINSPOWER}
USE INSULATION MAT AS NECESSARY
CONTROL VOLTAGE OUTPUT CLOCK
USE INSULATION MAT AS NECESSARY
System Information
- Total Tests: 228
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control