Set Appliance State:

Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
Remove the main control box cover to expose the control PCB
Use insulation mat as necessary
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset lockout as necessary.
Allow fan to run.
Measure voltage across connection 2 (brown lead) and connection 1 (blue lead) on connector marked CON 12 on the control PCB.
Note:
Voltage will only be present for approximately 3 seconds if burner does not prove.