Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove the main control box cover to expose the control PCB
Use insulation mat as necessary
Remove the main control box cover to expose the control PCB
Use insulation mat as necessary
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
All electrical heating controls calling.
Measure voltage across terminal 2 (orange lead) on connector marked CON 14 and connection 2 (blue lead) on connector marked CON 12.
Expected voltage - mains voltage.
Measure voltage across terminal 2 (orange lead) on connector marked CON 14 and connection 2 (blue lead) on connector marked CON 12.
Expected voltage - mains voltage.

Isolate as per TOPs P4
and refit as necessary