XSol Diagnostic System

Interactive Test Sequence Navigator

Welcome to the XSol Diagnostic System

This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.

Start Diagnostic Sequence

or choose a specific test below:

VOKERA 24 / 96 R.S.E. FLOWMATIC.

G.C. NUMBER 47 094 0

Next: &20, *

EXCESSIVE SYSTEM PRESSURE RISE

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
HEATING THERMOSTAT TO MAX

Next: &nff, !f147

FAN OVERRUN

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT

Next: &1, f142

CENTRAL HEATING

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
HEATING THERMOSTAT TO MAX

Next: &2, ?136, ?138, ?140

HOT WATER

ON/OFF SWITCH IN ON POSITION
DHW THERMOSTAT TO MAX
MODE SELECTOR SWITCH TO SUMMER

Next: &3, ?123, ?125, ?127

C/H MODULATION

{ISOLATEMAINSPOWER}<

Next: &4, !f122

C/H HIGH FLAME

{ISOLATEMAINSPOWER}<

Next: &5, f119

C/H BURNER IGNITES

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT

Next: &6, !f118

C/H FAN RUNS

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT

Next: &7, f109

DHW MODULATION

{ISOLATEMAINSPOWER}<

Next: &8, f102

DHW HIGH FLAME

{ISOLATEMAINSPOWER}<

Next: &9, f99

DHW FLAME SENSE

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
HEATING THERMOSTAT SET TO MAX

Next: &10, f96

DHW BURNER IGNITES

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
WATER THERMOSTAT TO MAX

Next: &11, f89

DHW SPARKING

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER

Next: &12, f72

DHW FAN RUNS

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
TURN HOT WATER TAP ON

Next: &13, f61

BOILER FLOW SWITCH OPERATION

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER

Next: &14, f38

MICROSWITCH C/H MODULATION

{ISOLATEMAINSPOWER}
REMOVE CONNECTOR PLUG 5 (CONNECTIONS 32-39)

Next: &15, !f37

MICROSWITCH DHW MODULATION

{ISOLATEMAINSPOWER}
REMOVE CONNECTOR PLUG 5 (CONNECTIONS 32-39)

Next: &16, !f36

DHW DEMAND

{ISOLATEMAINSPOWER}

Next: &17, f23

SYSTEM CHECKS

{ISOLATEMAINSPOWER}

Next: &18, !f22

VOKERA 24 / 96 R.S.E. FLOWMATIC.

{ISOLATEMAINSPOWER}<

Next: &19, !f21

DHW HIGH FLAME

DHW THERMOSTAT.

Next: End

MODULATION COIL RESISTANCE (FAIL)

MODULATION COIL.

Next: End

SELECTOR SWITCH

SELECTOR SWITCH.

Next: End

ROOM THERMOSTAT LINK

ROOM THERMOSTAT LINK.

Next: End

DELAY TIMER BOARD.

DELAY TIMER BOARD.

Next: End

CH BURNER IGNITES

BOILER THERMOSTAT.

Next: End

CH HIGH FLAME

BOILER THERMOSTAT.

Next: End

CH MODULATION

BOILER THERMOSTAT.

Next: End

FAN OVERRUN

PRINTED CIRCUIT BOARD.

Next: End

EXPANSION VESSEL

EXPANSION VESSEL.

Next: End

ELECTRICAL CHECK.

ELECTRICAL CHECK.

Next: End

SYSTEM CHECK

SYSTEM CHECK.

Next: End

DHW FLOW ADJUSTMENT (THROTTLE)

DHW FLOW ADJUSTMENT (THROTTLE).

Next: End

DHW FILTER.

DHW FILTER.

Next: End

DIVERTER VALVE DIAPHRAGM

DIVERTER VALVE DIAPHRAGM.

Next: End

DIVERTER VALVE VENTURI

DIVERTER VALVE VENTURI.

Next: End

MICROSWITCH DHW MODULATION

DHW MICROSWITCH ASSEMBLY.

Next: End

MICROSWITCH CH MODULATION

DHW MICROSWITCH ASSEMBLY.

Next: End

MAINS POWER SUPPLY

Next: End

ON/OFF SWITCH

ON/OFF SWITCH.

Next: End

PUMP CONNECTOR PLUG

PUMP CONNECTOR PLUG.

Next: End

BOILER FLOW SWITCH SPINDLE

BOILER FLOW SWITCH SPINDLE.

Next: End

DHW FAN RUNS

DHW MICROSWITCH ASSEMBLY.

Next: End

RELAY 1 NORMALLY OPEN VOLTAGE

PRINTED CIRCUIT BOARD.

Next: End

DHW FAN RUNS

BOILER FLOW SWITCH MICROSWITCH.

Next: End

AIR PRESSURE SWITCH TUBE

AIR PRESSURE SWITCH TUBE.

Next: End

FLUE

FLUE.

Next: End

FLUE VENTURI

FLUE VENTURI.

Next: End

HIGH LIMIT THERMOSTAT

HIGH LIMIT THERMOSTAT.

Next: End

SAFETY THERMOSTAT

SAFETY THERMOSTAT.

Next: End

ELECTRONIC IGNITION CONTROL CONNECTOR

ELECTRONIC IGNITION CONTROL CONNECTOR.

Next: End

GAS VALVE SOLENOID 1 (TOP)

GAS VALVE SOLENOID 1 (TOP).

Next: End

GAS VALVE SOLENOID 2 (BOTTOM)

GAS VALVE SOLENOID 2 (BOTTOM)

Next: End

DHW BURNER IGNITES

ELECTRONIC IGNITION CONTROL.

Next: End

SENSE ELECTRODE & LEAD

SENSE ELECTRODE AND LEAD.

Next: End

MODULATION COIL

MODULATION COIL.

Next: End

MODULATION COIL RESISTANCE (PASS)

MODULATION COIL.

Next: End

CH FAN RUNS

BOILER THERMOSTAT.

Next: End

C/H OPERATION: INSUFFICIENT WATER FLOW

C/H OPERATION: INSUFFICIENT WATER FLOW.

Next: End

MAXIMUM HEATING RATE POTENTIOMETER

MAXIMUM HEATING RATE POTENTIOMETER.

Next: End

DHW QUIET OPERATION, COLD RADIATORS

SECONDARY HEAT EXCHANGER.

Next: End

DIVERTER VALVE

DIVERTER VALVE.

Next: End

HOT WATER

SECONDARY HEAT EXCHANGER.

Next: End

HOT WATER

PRIMARY HEAT EXCHANGER.

Next: End

CENTRAL HEATING

PRIMARY HEAT EXCHANGER.

Next: End

CENTRAL HEATING

Next: End

FAN OVERRUN

BOILER FLOW SWITCH MICROSWITCH.

Next: End

FAN OVERRUN THERMOSTAT

FAN OVERRUN THERMOSTAT.

Next: End

DHW MODULATION

ELECTRONIC IGNITION CONTROL.

Next: End

DHW MODULATION

DHW THERMOSTAT.

Next: End

DHW MODULATION

PRINTED CIRCUIT BOARD.

Next: End

SECONDARY HEAT EXCHANGER (RESTRICTED FLOW)

SECONDARY HEAT EXCHANGER (RESTRICTED FLOW).

Next: End

DIVERTER VALVE SPINDLE

DIVERTER VALVE SPINDLE.

Next: End

BYPASS PLATE AND SPRING

BYPASS PLATE AND SPRING.

Next: End

BOILER FLOW SWITCH OPERATION

DHW MICROSWITCH ASSEMBLY.

Next: End

WATER PUMP

WATER PUMP.

Next: End

BOILER FLOW SWITCH DIAPHRAGM

BOILER FLOW SWITCH DIAPHRAGM.

Next: End

BOILER FLOW SWITCH VENTURI & BYPASS TUBE

BOILER FLOW SWITCH VENTURI AND BYPASS TUBE.

Next: End

INSUFFICIENT WATER FLOW

INSUFFICIENT WATER FLOW.

Next: End

DHW FAN RUNS

PRINTED CIRCUIT BOARD.

Next: End

DHW FAN RUNS

AIR PRESSURE SWITCH

Next: End

FAN

FAN.

Next: End

DHW SPARKING

AIR PRESSURE SWITCH

Next: End

SPARK ELECTRODE & LEAD

SPARK ELECTRODE AND LEAD.

Next: End

DHW SPARKING

ELECTRONIC IGNITION CONTROL.

Next: End

BURNER INJECTORS

BURNER INJECTORS.

Next: End

DHW FLAME SENSE

ELECTRONIC IGNITION CONTROL.

Next: End

DHW NOISY OPERATION

CHARACTERISTIC TEST FROM HOT WATER

Next: p124

DHW QUIET OPERATION, COLD RADIATORS

CHARACTERISTIC TEST FROM HOT WATER

Next: !p126

DHW QUIET OPEARTION, WARM RADIATORS

CHARACTERISTIC TEST FROM HOT WATER

Next: !p128

CH NOISY OPERATION, DHW NOISY OPERATION

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p131

CH NOISY OPERATION, DHW PREVIOUSLY OKAY

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p133

CH QUIET OPERATION

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p135

CH NOISY OPERATION, DHW NOISY OPERATION

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p137

CH NOISY OPERATION, DHW PREVIOUSLY OKAY

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p139

CH QUIET OPERATION

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p141

VOLTAGE PRESENT BUT DOESNT DROP

CHARACTERISTIC TEST FROM DHW THERMOSTAT CLOSED (HOT)

Next: !p152

NO VOLTAGE PRESENT AT ANY POINT

CHARACTERISTIC TEST FROM DHW THERMOSTAT CLOSED (HOT)

Next: !p154

FLOW SWITCH DIAPHRAGM SPLIT

CHARACTERISTIC TEST FROM BOILER FLOW SWITCH DIAPHRAGM

Next: !p56

FLOW SWITCH VENTURI BLOCKED

CHARACTERISTIC TEST FROM BOILER FLOW SWITCH DIAPHRAGM

Next: !p58

MODULATION COIL VOLTAGE

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
DHW THERMOSTAT TO MIN

Next: p104, f103

DHW THERMOSTAT CLOSED (HOT)

ON/OFF SWITCH IN ON

Next: !p150, ?151, ?153

BOILER THERMOSTAT 1ST STAGE

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT

Next: p111, f110

SELECTOR SWITCH IN CONSTANT POSITION

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT

Next: p113, !f112

C/H THERMOSTAT OPEN (COLD)

{ISOLATEMAINSPOWER}<

Next: !p121, !f120

FAN OVERRUN THERMOSTAT

{ISOLATEMAINSPOWER}<

Next: !p144, f143

RELAY 1 NORMALLY CLOSED CHECK

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER

Next: !p146, !f145

DHW FLOW RATE

Next: p25, f24

DHW FLOW ADJUSTMENT

{ISOLATEMAINSPOWER}

Next: p27, !f26

DIVERTER VALVE DIAPHRAGM

{ISOLATEMAINSPOWER}

Next: p33, !f32

DHW PUMP RUNS

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
DHW THERMOSTAT TO MAX

Next: p53, f39

DHW MICROSWITCH 1 OPERATION

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
DHW THERMOSTAT TO MAX

Next: p42, f41

MAINS POWER SUPPLY

ON/OFF SWITCH IN OFF POSITION

Next: p44, !f43

DC POWER SUPPLY

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
DHW THERMOSTAT TO MAX

Next: p63, f62

AIR PRESSURE SWITCH NO AIR VOLTAGE

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER

Next: !p65, f64

DHW MICROSWITCH 2 OPERATION

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
WATER THERMOSTAT TO MAX

Next: !p67, !f66

AIR PRESSURE SWITCH AIR DETECT VOLTAGE

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT

Next: p74, f73

AIR PRESSURE SWITCH TUBE

{ISOLATEMAINSPOWER}

Next: p76, !f75

HIGH LIMIT THERMOSTAT CONTINUITY

{ISOLATEMAINSPOWER}
REMOVE BOTH WHITE WIRES FROM HIGH LIMIT THERMOSTAT

Next: p84, !f83

GV1 SOLENOID RESISTANCE

{ISOLATEMAINSPOWER}
DISCONNECT AND REMOVE WIRES FROM OPERATOR

Next: p91, !f90

SENSE ELECTRODE & LEAD

{ISOLATEMAINSPOWER}

Next: !p98, !f97

DHW THERMOSTAT OPEN VOLTAGE (COLD)

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
DHW THERMOSTAT TO MAX

Next: !p101, !f100

MODULATION COIL RESISTANCE

{ISOLATEMAINSPOWER}
DISCONNECT WIRES FROM THE MODULATION COIL

Next: !p108, !f107

DELAY TIMER

ON/OFF SWITCH IN ON

Next: !p117, !f116

ROOM THERMOSTAT/LINK VOLTAGE

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT

Next: !p115, !f114

CENTRAL HEATING

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
HEATING THERMOSTAT TO MAX

Next: !p129, ?130, ?132, ?134

DIVERTER VALVE STIMULUS

{ISOLATEMAINSPOWER}

Next: !p31, f30

DHW FILTER

{ISOLATEMAINSPOWER}

Next: !p29, !f28

DIVERTER VALVE VENTURI

{ISOLATEMAINSPOWER}

Next: !p35, !f34

PUMP CONNECTOR VOLTAGE

ON/OFF SWITCH IN THE ON POSITION
MODE SELECTOR SWITCH TO SUMMER

Next: !p48, !f47

ON/OFF SWITCH OPERATION

ON/OFF SWITCH IN ON POSITION

Next: !p46, !f45

BOILER FLOW SWITCH DIAPHRAGM

{ISOLATEMAINSPOWER}

Next: p54, ?55, ?57

BOILER FLOW VALVE SPINDLE MOVE

{ISOLATEMAINSPOWER}

Next: !p60, !f59

RELAY 1 NORMALLY OPEN VOLTAGE

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
DHW THERMOSTAT TO MAX

Next: p69, !f68

FLOW SWITCH MICROSWITCH VOLTAGE

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER

Next: !p71, !f70

SPARK GENERATOR

ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER

Next: !p82, f81

FLUE

Next: p78, !f77

FLUE VENTURI

{ISOLATEMAINSPOWER}

Next: !p80, !f79

SAFETY THERMOSTAT RESISTANCE

{ISOLATEMAINSPOWER}
REMOVE BOTH WHITE WIRES FROM THERMOSTAT AND MAKE SAFE.

Next: p86, !f85

ELECTRONIC CONTROL BOX

{ISOLATEMAINSPOWER}

Next: !p88, !f87

GV2 SOLENOID RESISTANCE

{ISOLATEMAINSPOWER}
DISCONNECT AND REMOVE WIRES FROM OPERATOR

Next: p93, !f92

C/H MODULATION

{ISOLATEMAINSPOWER}<

Next: !p95, !f94

System Information

  • Total Tests: 148
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control