Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove connector plug 5 (connections 32-39)
Remove connector plug 5 (connections 32-39)
Measurement:
Measurements should be made on the disconnected end of the plug and not the PCB.
HW Tap ON:
Measure resistance between connection 39 on connector plug and DHW Thermostat (connection 2). Resistance should be short circuit.
HW Tap OFF:
Measure resistance between connection 39 on connector plug and DHW Thermostat (connection 2). Resistance should be open circuit.
HW Tap ON:
Measure resistance between connection 39 on connector plug and DHW Thermostat (connection 2). Resistance should be short circuit.
HW Tap OFF:
Measure resistance between connection 39 on connector plug and DHW Thermostat (connection 2). Resistance should be open circuit.

Isolate as per TOPs P4
and refit as necessary