Set Appliance State:
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
Connect a U-Gauge to the Gas Valve outlet pressure point
On/Off Switch in ON position
Mode Selector Switch to Summer
DHW Thermostat to MAX
Connect a U-Gauge to the Gas Valve outlet pressure point
On/Off Switch in ON position
Mode Selector Switch to Summer
DHW Thermostat to MAX
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Does the U-Gauge indicate high gas rate pressure (approximately 10 mbars) and the burner light to a high flame?
Note:
The boiler must not be at its full operating temperature.
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.
Note:
The boiler must not be at its full operating temperature.
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.
Isolate as per TOPs P4
and refit as necessary