VOKERA 20 / 80 R.S. FLOWMATIC.
GC NUMBER 47 094 07<
HOT WATER
DHW THERMOSTAT TO MAX
MODE SELECTOR SWITCH TO SUMMER
HOT WATER TAP ON
DHW MODULATION
{ISOLATEMAINSPOWER}<
DHW HIGH FLAME
{ISOLATEMAINSPOWER}<
DHW FAN HIGH SPEED
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
TURN HOT WATER TAP ON
HW DEMAND
{ISOLATEMAINSPOWER}
PUMP OVERRUN
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
CENTRAL HEATING
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
HEATING THERMOSTAT TO MAX
CH MODULATION
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
HEATING THERMOSTAT TO MAX
CH LOW FLAME
{ISOLATEMAINSPOWER}<
CH HIGH FLAME
{ISOLATEMAINSPOWER}<
CH FAN HIGH SPEED
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
SLOW FAN
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
PILOT FLAME FAILURE
{ISOLATEMAINSPOWER}
PILOT ESTABLISHED
{ISOLATEMAINSPOWER}
IGNITE PILOT
{ISOLATEMAINSPOWER}
SYSTEM CHECKS.
{ISOLATEMAINSPOWER}
VOKERA 20 / 80 R.S. FLOWMATIC
{ISOLATEMAINSPOWER}<
ELECTRODE SPARKING
{ISOLATEMAINSPOWER}
ELECTRICAL SAFETY CHECKS
ELECTRICAL SAFETY CHECKS
PILOT BURNER ASSEMBLY
PILOT BURNER ASSEMBLY
PIEZO SPARK UNIT EARTH
EARTH FOR PIEZO IGNITER
ELECTRODE LEAD
SPARK ELECTRODE LEAD
THERMOCOUPLE
THERMOCOUPLE
HIGH LIMIT THERMOSTAT
HIGH LIMIT THERMOSTAT
PILOT FLAME FAILURE
GAS VALVE
SYSTEM CHECKS
SYSTEM CHECKS
ON / OFF SWITCH
ON / OFF SWITCH
NO HIGH FLAME
PRINTED CIRCUIT BOARD
FLOW SWITCH SPINDLE
FLOW SWITCH SPINDLE
SAFETY THERMOSTAT
SAFETY THERMOSTAT
GAS VALVE COIL
GAS VALVE COIL/SOLENOID
CH HIGH FLAME
AIR TUBE
NO FLAME
VENTURI
CH HIGH FLAME
FAN (CONDITION)
FAN SPEED RESISTOR (560 OHM)
SLOW FAN SPEED RESISTOR (560 OHM)
CH HIGH FLAME
FLUE
NO POWER
PRINTED CIRCUIT BOARD
SLOW FAN
FLOW SWITCH MICROSWITCH
HEATING CONTROL SWITCH
HEATING CONTROL SWITCH
BOILER THERMOSTAT
BOILER THERMOSTAT
DC POWER SUPPLY
PRINTED CIRCUIT BOARD
CH RELAY 1 NORMALLY OPEN VOLTAGE
PRINTED CIRCUIT BOARD
NO POWER TO PUMP
PRINTED CIRCUIT BOARD
LOW FLAME
BOILER THERMOSTAT
DOMESTIC HOT WATER MICROSWITCH
DOMESTIC HOT WATER MICROSWITCH
MODULATION COIL
GAS VALVE MODULATION COIL
CH MODULATION
VENTURI
PUMP OVVERRUN
BOILER THERMOSTAT
FILTER (COLD WATER INLET)
FILTER (COLD WATER INLET)
DIVERTER VALVE DIAPHRAGM
DOMESTIC HOT WATER DIAPHRAGM
DHW FAN HIGH SPEED (FAIL)
DOMESTIC HOT WATER MICROSWITCH
DOMESTIC HOT WATER THERMOSTAT
DOMESTIC HOT WATER THERMOSTAT
DHW MODULATION
DOMESTIC HOT WATER THERMOSTAT
DIVERTER VALVE
THREE PORT DIVERTER VALVE
CH MODULATION
BOILER THERMOSTAT
PIEZO IGNITOR
PIEZO SPARK UNIT
IGNITE PILOT
GAS VALVE
SPARK ELECTRODE
SPARK ELECTRODE
HW DEMAND
PRINTED CIRCUIT BOARD
PILOT ESTABLISHED
GAS VALVE
SLOW FAN
PRINTED CIRCUIT BOARD
BURNER
BURNER
NO FLAME
GAS VALVE
NO FLAME
AIR PRESSURE SWITCH
FLUE VENTURI
VENTURI
NOT LIGHTING
GAS VALVE
FAN
FAN
ROOM THERMOSTAT CONNECTIONS
ROOM THERMOSTAT CONNECTIONS
AIR PRESSURE SWITCH
AIR PRESSURE SWITCH
CH RELAY 1 NORMALLY OPEN VOLTAGE
FLOW SWITCH MICROSWITCH
PUMP
PUMP
SPLIT
DIAPHRAGM CH FLOW SWITCH
LOW FLAME
PRINTED CIRCUIT BOARD
CH LOW FLAME
GAS VALVE
PRIMARY HEAT EXCHANGER
PRIMARY HEAT EXCHANGER
DIVERTER VALVE SPINDLE
DIVERTER VALVE SPINDLE
DHW HIGH FLAME
DOMESTIC HOT WATER MICROSWITCH
DHW MODULATION
DOMESTIC HOT WATER MICROSWITCH
SECONDARY HEAT EXCHANGER
SECONDARY HEAT EXCHANGER
HOT RADIATORS
CHARACTERISTIC TEST FROM HOT WATER.
LOW FLAME
CHARACTERISTIC TEST FROM CH HIGH FLAME.
NO FLAME
CHARACTERISTIC TEST FROM CH HIGH FLAME.
NOISILY
CHARACTERISTIC TEST FROM CENTRAL HEATING.
QUIETLY
CHARACTERISTIC TEST FROM CENTRAL HEATING.
COLD RADIATORS
CHARACTERISTIC TEST FROM HOT WATER.
27/11/2017 10:02:50 1709_1_50_1 09/01/2018 08:45:50
27/11/2017 13:10:41
PILOT INJECTOR BLOCKED
{ISOLATEMAINSPOWER}
PIEZO EARTH CHECK
{ISOLATEMAINSPOWER}
ELECTRODE LEAD/ ELECTRODE
{ISOLATEMAINSPOWER}
THERMOCOUPLE VOLTAGE
{ISOLATEMAINSPOWER}
RELAY 1 NORMALLY CLOSED CHECK
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
MAINS POWER SUPPLY
ON/OFF SWITCH IN OFF POSITION
VOLTAGE AIR PRESSURE SWITCH COMMON
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
GAS VALVE SOLENOID RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT AND REMOVE WIRES FROM SOLENOID BEFORE TESTING.
VOLTAGE AIR PRESSURE SWITCH COMMON
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
CH - AIR PRESSURE SWITCH NORMALLY CLOSED
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
ROOM THERMOSTAT/LINK VOLTAGE
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
SELECTOR SWITCH IN CONSTANT POSITION
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
HEATING THERMOSTAT TO MAX
AIR PRESSURE SWITCH NORMALLY OPEN VOLTAGE
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
DHW MICROSWITCH NORMALLY CLOSED CHECK
{ISOLATEMAINSPOWER}
ON/OFF SWITCH IN OFF POSITION
BLOCKED VENTURI
{ISOLATEMAINSPOWER}
DHW FILTER
{ISOLATEMAINSPOWER}
RESISTANCE DHW MICROSWITCHES
{ISOLATEMAINSPOWER}
DHW THERMOSTAT RESISTANCE (COLD)
{ISOLATEMAINSPOWER}
DHW THERMOSTAT RESISTANCE (MODULATING)
{ISOLATEMAINSPOWER}
ENSURE THAT THE BOILER IS AT ITS FULL OPERATING TEMPERATURE
ELECTRODE LEAD AND ELECTRODE
{ISOLATEMAINSPOWER}
HIGH LIMIT THERMOSTAT CONTINUITY
{ISOLATEMAINSPOWER}
FLOW SWITCH SPINDLE
{ISOLATEMAINSPOWER}
REMOVE PLASTIC COVER FROM FLOWSWITCH
ON/OFF SWITCH OPERATION
ON/OFF SWITCH IN ON POSITION
SAFETY THERMOSTAT RESISTANCE
{ISOLATEMAINSPOWER}
BURNER PRESSURE
{ISOLATEMAINSPOWER}<
FAN SPEED (560 OHM) RESISTOR
{ISOLATEMAINSPOWER}
APS TUBES
{ISOLATEMAINSPOWER}
BLOCKED VENTURI
{ISOLATEMAINSPOWER}
FAN CONDITION
{ISOLATEMAINSPOWER}
REMOVE FAN ASSEMBLY
SLOW FAN VOLTAGE
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO SUMMER
CH FLOW SWITCH MICROSWITCH
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
BOILER THERMOSTAT 2ND. STAGE
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
DC POWER SUPPLY
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
HEATING THERMOSTAT TO MAX
CH RELAY 1 NORMALLY OPEN VOLTAGE
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
HEATING THERMOSTAT TO MAX
MODUREG SOLENOID SLUG FAILURE
{ISOLATEMAINSPOWER}<
AIR PRESSURE SWITCH NORMALLY OPEN VOLTAGE
ON/OFF SWITCH IN ON POSITION
MODE SELECTOR SWITCH TO CONSTANT
BOILER THERMOSTAT (COLD) RESISTANCE
{ISOLATEMAINSPOWER}
ENSURE THAT THE BOILER IS NOT AT ITS FULL OPERATING TEMPERATURE
MODULATION COIL RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT WIRES FROM THE MODULATION COIL
DIVERTER VALVE DIAPHRAGM.
{ISOLATEMAINSPOWER}