XSol Diagnostic System

Interactive Test Sequence Navigator

Welcome to the XSol Diagnostic System

This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.

Start Diagnostic Sequence

or choose a specific test below:

GLOW WORM SWIFTFLOW 100 HONEYWELL CONTROL

G.C. NUMBER 47 313 0

Next: &1, *

GLOW WORM SWIFTFLOW 100 HONEYWELL CONTROL

{ISOLATEMAINSPOWER}<

Next: &3, !f2

SYSTEM CHECKS

PLEASE ENSURE THAT THE FOLLOWING SYSTEM CHECKS ARE COMPLETED.

Next: &136, !f4

IGNITE PILOT

{ISOLATEMAINSPOWER}
SELECTOR SWITCH OFF
GAS CONTROL KNOB FULLY DEPRESSED IN PILOT POSITION

Next: &23, f15

ESTABLISH PILOT

{ISOLATEMAINSPOWER}
SELECTOR SWITCH OFF
GAS CONTROL KNOB FULLY DEPRESSED

Next: &29, f24

FLAME FAILURE

{ISOLATEMAINSPOWER}<

Next: &32, !f112

SLOW FAN

{ISOLATEMAINSPOWER}
GAIN ACCESS TO THE COMBUSTION CHAMBER TO OBSERVE THE FAN
ENSURE NO DEMANDS

Next: &40, ?117, ?119, ?204

MAINS LED

SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &46, f41

LOW SYSTEM PRESSURE LED

SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &161, f47

CH PUMP RUNS

SELECTOR SWITCH ON
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &66, f63

CH BURNER IGNITES

SELECTOR SWITCH ON
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &82, f67

CH MODULATION

SELECTOR SWITCH ON
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &88, f154

DHW RUNNING LED

SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &92, f187

DHW HIGH FAN

SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &94, !f93

DHW BURNER IGNITES

SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &96, !f95

DHW OVERRUN

SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &98, !f97

DHW MODULATION

{ISOLATEMAINSPOWER}<

Next: &102, f99

CENTRAL HEATING

SELECTOR SWITCH ON
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &107, ?103, ?105

HOT WATER

SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &nff, !f108

SPARKING

{ISOLATEMAINSPOWER}
SELECTOR SWITCH OFF
GAS CONTROL KNOB FULLY DEPRESSED

Next: &11, f137

CH HIGH FAN

SELECTOR SWITCH ON
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: &62, f162

DHW MODULATION

KIT - PCB

Next: End

HOT WATER

HEAT EXCHANGER

Next: End

FLAME FAILURE

GAS VALVE ASSEMBLY

Next: End

SLOW FAN

Next: End

SLOW FAN

KIT - PCB

Next: End

SLOW FAN

FLOW SWITCH - PLATON (DHW)

Next: End

SLOW FAN

FUSE 1.6A FS1

Next: End

SPARKING

ELECTRODE - BUCCLEUCH

Next: End

SPARKING

LEAD - IGNITION SPECIAL

Next: End

CH BURNER IGNITES

THERMISTOR ASSEMBLY - SPARES SPECIAL (CH)

Next: End

CH BURNER IGNITES

PRESSURE SWITCH SQUARE PLASTIC (LOW WATER)

Next: End

CH MODULATION

MODULATION COIL

Next: End

CH MODULATION

THERMISTOR ASSEMBLY - SPARES SPECIAL (CH)

Next: End

CH MODULATION

USER PCB - SPECIAL

Next: End

CH RUNNING LED

LIGHT SWITCH - SIGNAL (SELECTOR SWITCH)

Next: End

CH HIGH FAN NEW PCB

KIT - PCB

Next: End

CH MODULATION

POTENTIOMETER SETTINGS

Next: End

CH BURNER IGNITES

AIR PRESSURE SWITCH TUBES

Next: End

CH BURNER IGNITES

FLUE

Next: End

WORN

PRESSURE SWITCH - AIR - HONEYWELL

Next: End

WORN DIRTY

FAN ASSEMBLY

Next: End

OUT OF RANGE

THERMISTOR ASSEMBLY (DHW)

Next: End

DHW RUNNING LED

FILTER - WATER

Next: End

ELECTRICAL CHECKS

ELECTRICAL CHECK

Next: End

MAINS LED FAN ONLY RUNS SLOWLY

FUSE 630MA FS2

Next: End

IGNITE PILOT

INJECTOR - PILOT - SPARES

Next: End

ESTABLISH PILOT

THERMOCOUPLE

Next: End

SYSTEM CHECKS

SYSTEM CHECKS

Next: End

MAINS LED

FUSE 630MA FS2

Next: End

MAINS LED

TRANSFORMER

Next: End

LOW SYSTEM PRESSURE LED

SYSTEM PRESSURE

Next: End

LOW SYSTEM PRESSURE LED

PRESSURE SWITCH SQUARE PLASTIC (LOW WATER)

Next: End

CH PUMP RUNS

KIT - PCB

Next: End

DHW HIGH FAN

KIT - PCB

Next: End

DHW BURNER IGNITES

THERMISTOR ASSEMBLY (DHW)

Next: End

DHW OVERRUN

KIT - PCB

Next: End

DHW MODULATION

THERMISTOR ASSEMBLY (DHW)

Next: End

CENTRAL HEATING

HEAT EXCHANGER

Next: End

CENTRAL HEATING

Next: End

ESTABLISH PILOT

GAS VALVE ASSEMBLY

Next: End

IGNITE PILOT

GAS VALVE ASSEMBLY

Next: End

SLOW FAN

FAN ASSEMBLY

Next: End

SLOW FAN 3

KIT - PCB

Next: End

SLOW FAN 2

KIT - PCB

Next: End

SPARKING

SPARK GENERATOR

Next: End

NO GV POWER

KIT - PCB

Next: End

CH BURNER IGNITES

HIGH LIMIT CONTROL (DHW)

Next: End

CH HIGH FAN

Next: End

CH MODULATION

KIT - PCB

Next: End

CH BURNER IGNITES (1)

GAS VALVE ASSEMBLY

Next: End

NOT ENOUGH PRESSURE

FAN ASSEMBLY

Next: End

DHW RUNNING LED

KIT - PCB

Next: End

DHW RUNNING LED

FLOW SWITCH - PLATON (DHW)

Next: End

CH RUNNING LED

INTERFACE PCB - SPECIAL

Next: End

CH HIGH FAN

KIT - PCB

Next: End

NEUTRAL FAULT

KIT - PCB

Next: End

FAN ONLY RUNS SLOWLY

KIT - PCB

Next: End

ESTABLISH PILOT

THERMOSTAT - OVERHEAT CUT-OFF CH

Next: End

MAINS LED

USER PCB - SPECIAL

Next: End

LOW SYSTEM PRESSURE LED

USER PCB - SPECIAL

Next: End

CH PUMP RUNS

PUMP - CIRCULATOR

Next: End

Noisy operation

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p104

Quiet operation

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p106

Fan does not run

CHARACTERISTIC TEST FROM SLOW FAN

Next: p121

Fan does not slow down

CHARACTERISTIC TEST FROM SLOW FAN

Next: p120

APPROXIMATELY 0VDC MEASURED ON TEST 1

CHARACTERISTIC TEST FROM VOLTAGE INTERFACE PCB TO MAIN PCB

Next: !p201

VOLTAGE OK ON TEST 1, BUT NOT ON TEST 2

CHARACTERISTIC TEST FROM VOLTAGE INTERFACE PCB TO MAIN PCB

Next: !p203

FAN ONLY RUNS SLOWLY

CHARACTERISTIC TEST FROM SLOW FAN

Next: p206

MAINS POWER SUPPLY

{ISOLATEMAINSPOWER}
SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: p130, !f125

ELECTRODE

{ISOLATEMAINSPOWER}
REMOVE FRONT COMBUSTION COVER

Next: p138, !f139

CH THERMISTOR

{ISOLATEMAINSPOWER}<

Next: p148, !f149

PILOT INJECTOR

{ISOLATEMAINSPOWER}

Next: !p111, !f21

WATER PRESSURE SWITCH (PRESSURISED)

{ISOLATEMAINSPOWER}<

Next: !p152, !f153

MODULATION COIL RESISTANCE

{ISOLATEMAINSPOWER}<

Next: p155, !f156

SELECTOR SWITCH

{ISOLATEMAINSPOWER}<

Next: p163, !f164

RESISTANCE APS USING TEST KIT

{ISOLATEMAINSPOWER}
REMOVE TUBES FROM APS.
ATTACH MULTIMETER TO APS USING CROCODILE CLIPS.

Next: p178, !f184

DHW FLOW SWITCH

{ISOLATEMAINSPOWER}
DISCONNECT THE DHW FLOW SWITCH INLINE CONNECTOR

Next: p190, f194

DHW INLET FILTER

{ISOLATEMAINSPOWER}
WATER OFF

Next: !p196, !f195

BOILER OVERHEAT VOLTAGE

{ISOLATEMAINSPOWER}
SELECTOR SWITCH OFF
GAS CONTROL KNOB FULLY DEPRESSED.

Next: !p110, f25

THERMOCOUPLE

{ISOLATEMAINSPOWER}
SELECTOR SWITCH OFF
GAS CONTROL KNOB FULLY DEPRESSED.

Next: !p27, !f26

FUSE FS2

{ISOLATEMAINSPOWER}

Next: p43, !f42

SYSTEM PRESSURE

{ISOLATEMAINSPOWER}

Next: p49, !f48

WATER PUMP VOLTAGE

{ISOLATEMAINSPOWER}
SELECTOR SWITCH ON
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: !p65, !f64

AIR PRESSURE SWITCH

{ISOLATEMAINSPOWER}<

Next: p73, f177

DHW POTENTIOMETER

{ISOLATEMAINSPOWER}
REMOVE KNOB FROM CH POTENTIOMETER ON MAIN PCB

Next: !p101, !f100

DHW FLOW SWITCH (OPEN CIRCUIT)

{ISOLATEMAINSPOWER}
DISCONNECT THE DHW FLOW SWITCH INLINE CONNECTOR

Next: !p128, !f129

TRANSFORMER

{ISOLATEMAINSPOWER}
SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: p122, f123

SLOW FAN VOLTAGE

{ISOLATEMAINSPOWER}
SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: !p126, !f127

FUSE FS1

{ISOLATEMAINSPOWER}

Next: !p131, !f132

ELECTRODE LEAD

{ISOLATEMAINSPOWER}
DISCONNECT ELECTRODE LEAD

Next: !p140, !f141

DHW HIGH LIMIT CONTROL

{ISOLATEMAINSPOWER}<

Next: !p150, f151

CH THERMISTOR

{ISOLATEMAINSPOWER}<

Next: p157, !f158

CH POTENTIOMETER

{ISOLATEMAINSPOWER}<

Next: p172, !f160

LINK OUT EXTERNAL CONTROLS

{ISOLATEMAINSPOWER}
LINK PINS 1 AND 2 OF FIVE POLE CONNECTOR ON MOUNTING FRAME

Next: !p165, f166

VOLTAGE INTERFACE PCB TO MAIN PCB

{ISOLATEMAINSPOWER}
SELECTOR SWITCH ON

Next: !p199, ?200, ?202

OBSERVATION CONTROL PCB CH POTENTIOMETER SETTING

{ISOLATEMAINSPOWER}

Next: !p173, !f174

AIR PRESSURE SWITCH TUBES

{ISOLATEMAINSPOWER}

Next: p180, !f179

INSPECTION FAN AND VENTURI

REMOVE THE FAN ASSEMBLY FROM THE BOILER

Next: p181, !f185

FLUE

Next: !p186, !f183

RESISTANCE DHW THERMISTOR

{ISOLATEMAINSPOWER}
DISCONNECT CONNECTOR CN4

Next: !p191, !f192

FUSE FS2

{ISOLATEMAINSPOWER}

Next: !p211, !f208

TRANSFORMER

{ISOLATEMAINSPOWER}
SELECTOR SWITCH OFF
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: !p45, !f44

WATER PRESSURE SWITCH (LOW PRESSURE)

{ISOLATEMAINSPOWER}
SYSTEM PRESSURISED

Next: !p51, !f50

CH SOLENOID COIL VOLTAGE

{ISOLATEMAINSPOWER}
SELECTOR SWITCH ON
GAS CONTROL KNOB IN MAIN BURNER POSITION

Next: !p176, f147

System Information

  • Total Tests: 128
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control