Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Selector Switch ON
Gas Control Knob in Main Burner position
Unplug connector CN4
Selector Switch ON
Gas Control Knob in Main Burner position
Unplug connector CN4
Measurement:
Selector Switch Off.
Check for open circuit resistance across Selector Switch (Brown wires on connector block CN4).
Selector Switch On.
Check for short circuit resistance across Selector Switch (Brown wires on connector block CN4).
Replace connector CN4
Check for open circuit resistance across Selector Switch (Brown wires on connector block CN4).
Selector Switch On.
Check for short circuit resistance across Selector Switch (Brown wires on connector block CN4).
Replace connector CN4

Isolate as per TOPs P4
and refit as necessary