Set Appliance State:
Mains Power Off
Gas On; Pilot On
CH Demand
Selector Switch ON
Gas Control Knob in Main Burner position
Gas Control Knob in Main Burner position
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow the burner to ignite.
Run the heating to build up temperature inside the boiler
Slowly turn the potentiometer down towards the minimum position while observing the U-Gauge
Does the gas pressure decrease as the burner modulates ?
Note:
When U-gauge is removed pressure test point should be tightened and checked for gas soundness.
Run the heating to build up temperature inside the boiler
Slowly turn the potentiometer down towards the minimum position while observing the U-Gauge
Does the gas pressure decrease as the burner modulates ?
Note:
When U-gauge is removed pressure test point should be tightened and checked for gas soundness.
Isolate as per TOPs P4
and refit as necessary