VOKERA PRO COMBI A
GLOBALLY REPLACED
OBSERVATION BOILER SELF CHECK
SELECTOR SWITCH TO DHW & CH WITH NO PREHEAT
ENSURE NO DEMANDS AND THAT THE BOILER IS COOL
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
OBSERVATION FAN RUNS
CH & DHW TEMPERATURE
PRESSURE GAS INLET (DHW DEMAND)
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
FUSE FURTHER INVESTIGATION
NOT USED
AL 20 26 28 74 79 (OVERHEAT / CIRCULATION FAULTS)
HEADER FOR FAULT CODE - OUTSIDE MODEL
AL 40 (SYSTEM PRESSURE FAULT) FINAL
HEADER FOR FAULT CODE - OUTSIDE MODEL
AL 60 (DHW THERMISTOR FAULT)
HEADER FOR FAULT CODE - OUTSIDE MODEL
INSPECTION CONTROL KNOB ALIGNMENT
{GAINPCBACS}
POSI
AL 34 (FAN FAULT)
HEADER FOR FAULT CODE - OUTSIDE MODEL
AL 55 (JUMPER TAG FAULT)
HEADER FOR FAULT CODE - OUTSIDE MODEL
AL 52 (INTERNAL FAULT)
HEADER FOR FAULT CODE - OUTSIDE MODEL
AL 21 (EXTERNAL DEVICE FAULT)
HEADER FOR FAULT CODE - NOT USED
AL 73 RETURN THERMISTOR FAULT
HEADER FOR FAULT CODE - OUTSIDE MODEL
AL 71 PRIMARY (FLOW) THERMISTOR FAULT
HEADER FOR FAULT CODE - OUTSIDE MODEL
AL 41 (SYSTEM PRESSURE)
HEADER FOR FAULT CODE - OUTSIDE MODEL
OPERATION PREHEAT
ENSURE APPLIANCE IS
CL AND ST INFORMATION
CL OR ST IS THE APPL
AIR PURGE CYCLE INFORMATION
SOME VERSIONS OF THE
DHW FLOW RATE
STOP COCK - WATER SUPPLY
DHW FLOW RATE
COLD WATER SUPPLY
FAN DOES NOT RUN
FAN
FAN DOES NOT RUN
PRINTED CIRCUIT BOARD
PUMP DOES NOT RUN
PRINTED CIRCUIT BOARD
PUMP DOES NOT RUN
HARNESS - WIRING
BURNER DOES NOT IGNITE
CONDENSATE
BURNER DOES NOT IGNITE
GAS INLET PRESSURE
BURNER DOES NOT IGNITE
MIXER
BURNER DOES NOT IGNITE
COMPENSATION TUBE
BURNER DOES NOT IGNITE 2
COMPENSATION TUBE
BURNER DOES NOT IGNITE 2
MIXER
BURNER DOES NOT IGNITE 2
HARNESS - WIRING
BOILER DOES NOT EST
CONDENSATE
BOILER DOES NOT EST
COMPENSATION TUBE
BOILER DOES NOT EST
GAS INLET PRESSURE
BOILER DOES NOT EST
FLUE
BURNER BAFFLES OR NOISY
CONDENSATE
BURNER BAFFLES OR NOISY
COMPENSATION TUBE
BURNER BAFFLES OR NOISY
GAS INLET PRESSURE
BURNER BAFFLES OR NOISY
MIXER
DHW TOO HOT
SENSOR - NTC
DHW HOT THEN COOL
PUMP
DHW HOT THEN COOL
SENSOR - NTC
DHW HOT THEN COOL
DETECTOR - WATER
DHW HOT THEN COOL
VALVE - NON RETURN
CH OPERATION
EXPANSION VESSEL
CH OPERATION
VALVE 22MM - HEATING
CH OPERATION
DETECTOR - WATER
CH OPERATION 2
DETECTOR - WATER
CH OPERATION 2
PUMP
LEDS DO NOT WORK
FUSE (FUSED SPUR)
LEDS DOT NOT WORK
MAINS INPUT FUSE
LEDS DO NOT WORK
FUSE F1
RESISTANCE SPARK GENERATOR
TRANSFORMER - IGNITION
FUSE FURTHER INVESTIGATION
VALVE - MOTORIZED
FAULT CODE 2
Z REDIRECT
FAULT CODE RED SOLID
THERMOSTAT - HIGH LIMIT
FAN DOES NOT RUN 2
HARNESS - WIRING
BURNER DOES NOT IGNITE
PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
HARNESS - WIRING
BOILER DOES NOT EST
MIXER
CASE REMOVAL
Z REDIRECT
BOILER FIRES NO DEMAND
DETECTOR - WATER
BOILER FIRES NO DEMAND
SENSOR - NTC
CONTROL KNOB ALIGNMENT
CONTROL KNOB ALIGNMENT
BURNER DOES NOT IGNITE
SPARK - IGNITION - ELECTRODE
RECTIFICATION SECTION
HARNESS - WIRING
HIGH RESISTANCE OR DISTORTED
ELECTRODE - FLAME DETECTION
RECTIFICATION SECTION 2
HARNESS - WIRING
SHORTING TO EARTH
ELECTRODE - FLAME DETECTION
NOT SWITCHING
TIMER
NOT SWITCHING 2
TIMER
OVERHEAT
DETECTOR - WATER
OVERHEAT 2
DETECTOR - WATER
OVERHEAT
SENSOR - NTC
OVERHEAT 2
PRINTED CIRCUIT BOARD
OVERHEAT 2
HARNESS - WIRING
OVERHEAT 2
PUMP
WRONG PLACES
JUMPER TAGS
AL 52
PRINTED CIRCUIT BOARD
FAN FAULT CODE
HARNESS - WIRING
FAN DOES NOT RUN 5
PRINTED CIRCUIT BOARD
AL 60
HARNESS - WIRING
AL 71
DETECTOR - WATER
AL 73
DETECTOR - WATER
AL 40
PRINTED CIRCUIT BOARD
NO SPARK
CABLE - SPARK
NO LEDS / DISPLAY
FUSE F2
TRIPPED
THERMOSTAT - HIGH LIMIT
DHW RADS BEGIN TO HEAT
PRINTED CIRCUIT BOARD
DHW RADS BEGIN TO HEAT
HARNESS - WIRING
CH RADS HEAT
CARTRIDGE - 3 WAY VALVE
CH OPERATION
PUMP
CH OPERATION 2
PRINTED CIRCUIT BOARD
CH OPERATION
HARNESS - WIRING
BOILER FIRES NO DEMAND
HARNESS - WIRING
BOILER FIRES NO DEMAND
DOMESTIC PLUMBING
FUSE FURTHER INVESTIGATION 5
HARNESS - WIRING
FUSE FURTHER INVESTIGATION
SOLENOID
BURNER DOES NOT IGNITE
HARNESS & PRINTED CIRCUIT BOARD
BURNER DOES NOT IGNITE
SOLENOID - GAS VALVE & PRINTED CIRCUIT BOARD
OVERHEAT
HEAT EXCHANGER ASSEMBLY - WATERWAYS
FAULT CODE RED BLINKING
VALVE - NON RETURN
EXCESSIVE FLUE GAS TEMPERATURE
CONDENSING HEAT EXCHANGER ASSEMBLY - FLUEWAYS
FAULT CODE RED SOLID 2
THERMOSTAT - HIGH LIMIT
OVERHEAT 3
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL
PUMP
DHW COOL RADS COOL
SENSOR - NTC
DHW COOL RADS COOL
DETECTOR - WATER
DHW COOL RADS COOL
VALVE - NON RETURN
DHW COOL RADS COOL
PLUMBING ISSUE
DHW COOL RADS COOL 2
FLUE
DHW COOL RADS COOL 2
MIXER
DHW COOL RADS COOL 2
VALVE - BY-PASS - AUTO
DHW COOL RADS COOL
FLUE
DHW COOL RADS COOL
MIXER
DHW COOL RADS COOL
VALVE - BY-PASS - AUTO
MAXIMUM OUTPUT INFORMATION
Z REDIRECT
PUMP OVERRUN FAULTY
PRINTED CIRCUIT BOARD
PREHEAT FAULTY
PRINTED CIRCUIT BOARD
BLANK FOR CL AND ST INFORMATION
Z REDIRECT
FAN DOES NOT RUN
DETECTOR - WATER
FAN DOES NOT RUN 2
DETECTOR - WATER
FAN DOES NOT RUN
SENSOR - NTC
NO SUPPLY TO FAN
PRINTED CIRCUIT BOARD
BLANK FOR EXTERNAL DEVICES
Z REDIRECT
NO PERMANENT SUPPLY FOR FAULT CODE
PRINTED CIRCUIT BOARD
NO PERMANENT SUPPLY RUNNING CONTINUOUSLY
PRINTED CIRCUIT BOARD
DEMAND WHEN SHOULDNT BE
PRINTED CIRCUIT BOARD
MAX AND MIN FAN SPEEDS
PCB POTENTIOMETERS (MAX AND MIN)
FAN SECTION RUNNING CONTINUOUSLY
HARNESS - WIRING
MAX AND MIN FAN SPEEDS 2
PCB POTENTIOMETERS (MAX AND MIN)
CH OPERATION
VALVE - BY-PASS - AUTO
PCB POTENTIOMETERS (HEATING FAN SPEED)
PCB POTENTIOMETER (HTG)
BURNER DOES NOT IGNITE POOR IGNITION
CONDENSATE
BURNER DOES NOT IGNITE POOR IGNITION
GAS INLET PRESSURE
BURNER DOES NOT IGNITE POOR IGNITION
COMPENSATION TUBE
NO SPARK POOR IGNITION
CABLE - SPARK
BURNER DOES NOT IGNITE POOR IGNITION
SPARK - IGNITION - ELECTRODE
PCB POTENTIOMETERS (IGNITION)
PCB POTENTIOMETER (IGN)
BLANK FOR AIR PURGE CYCLE INFORMATION
Z REDIRECT
NO POWER TO DIVERTER ROUND HEAD
PRINTED CIRCUIT BOARD
DIVERTER VALVE SECTION ROUND
HARNESS - WIRING
CH OPERATION 2 COMPACT VERSION
PRINTED CIRCUIT BOARD
CH OPERATION COMPACT VERSION
HARNESS - WIRING
CH RADS HEAT COMPACT VERSION
CARTRIDGE - 3 WAY VALVE
CH OPERATION COMPACT VERSION
VALVE - BY-PASS - AUTO
OVERHEAT INVESTIGATION
VALVE 22MM - HEATING
WRONG PLACES CAUSING 60 FAULT CODE
JUMPER TAGS
OVERHEAT WONT RESET
DETECTOR - WATER
OVERHEAT WONT RESET 2
DETECTOR - WATER
ON WHEN SHOULD BE OFF
TIMER
CO MODE ACTIVATED
CO MODE ACTIVATED
GAS INLET DHW DEMAMD
GAS INLET PRESSURE
TYPE OF DIAGNOSTIC PROCEDURE
Z REDIRECT
DHW FLOW RATE
HEAT EXCHANGER - PLATE
DHW FLOW RATE
GOVERNOR - FLOW
DHW FLOW RATE
ACTUATOR - DHW
DHW FLOW RATE
INLET FILTER - DHW
FAN DOES NOT RUN
HARNESS - WIRING
PUMP DOES NOT RUN
PUMP
NOT OPENING
VALVE - GAS
BURNER DOES NOT IGNITE 2
BURNER ASSEMBLY
BURNER DOES NOT IGNITE 2
CONDENSING HEAT EXCHANGER ASSEMBLY - FLUEWAYS
BURNER BAFFLES OR NOISY
BURNER ASSEMBLY
BURNER BAFFLES OR NOISY
CONDENSING HEAT EXCHANGER ASSEMBLY - FLUEWAYS
DHW TOO HOT
PRINTED CIRCUIT BOARD
DHW HOT THEN COOL
PRINTED CIRCUIT BOARD
DHW HOT THEN COOL
HEAT EXCHANGER - PLATE
DHW HOT THEN COOL
HEAT EXCHANGER ASSEMBLY - WATERWAYS
CH OPERATION
PIPE - FLEXIBLE
CH OPERATION
GAUGE - PRESSURE - QUICK PRIMER
CH OPERATION
SYSTEM PRESSURE
CH OPERATION 2
GAUGE - PRESSURE - QUICK PRIMER
CH OPERATION 2
SYSTEM PRESSURE
DHW HOT THEN COOL
GAUGE - PRESSURE - QUICK PRIMER
DHW HOT THEN COOL
SYSTEM PRESSURE
DHW COOL RADS COOL
GAUGE - PRESSURE - QUICK PRIMER
DHW COOL RADS COOL
SYSTEM PRESSURE
FUSE FIURTHER INVESTIGATION 2
Z REDIRECT
LEDS DO NOT WORK
HARNESS - WIRING
FUSE FIURTHER INVESTIGATION
Z REDIRECT
FUSE FIURTHER INVESTIGATION 3
Z REDIRECT
FUSE FURTHER INVESTIGATION
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 3
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 2
HARNESS - WIRING
FUSE FURTHER INVESTIGATION 4
HARNESS - WIRING
FAULT CODE
Z REDIRECT
OVERHEAT
GAUGE - PRESSURE - QUICK PRIMER
OVERHEAT
SYSTEM PRESSURE
AL 40
HARNESS - WIRING
AL 40
SWITCH - PRESSURE
AL 40
GAUGE - PRESSURE - QUICK PRIMER
AL 40
SYSTEM PRESSURE
BURNER DOES NOT IGNITE
BURNER ASSEMBLY
BURNER DOES NOT IGNITE
CONDENSING HEAT EXCHANGER ASSEMBLY - FLUEWAYS
BURNER DOES NOT IGNITE
TRANSFORMER - IGNITION
BOILER FIRES NO DEMAND
FROST PROTECTION MODE
BOILER FIRES NO DEMAND 2
PRINTED CIRCUIT BOARD
BOILER DOES NOT EST
PRINTED CIRCUIT BOARD
BOILER DOES NOT EST
BURNER ASSEMBLY
BOILER DOES NOT EST
CONDENSING HEAT EXCHANGER ASSEMBLY - FLUEWAYS
SHORTED TO EARTH
ELECTRODE - DETECTION
OPEN CIRCUIT
CLOCK WIRES (HARNESS - WIRING)
OPEN CIRCUIT 2
CLOCK WIRES (HARNESS - WIRING)
OPEN CIRCUIT 2 DHW RUNS HOT AND COLD
CLOCK WIRES (HARNESS - WIRING)
OPEN CIRCUIT DHW RUNS HOT AND COLD
CLOCK WIRES (HARNESS - WIRING)
OVERHEAT
PUMP
AL 55
PRINTED CIRCUIT BOARD
BLANK FOR RESET ATTEMPT AL 52
Z REDIRECT
AL 34
PRINTED CIRCUIT BOARD
FAN DOES NOT RUN 4
HARNESS - WIRING
FAN DOES NOT RUN 4
PRINTED CIRCUIT BOARD
AL 20
PRINTED CIRCUIT BOARD
AL 60
SENSOR - NTC
AL 71
HARNESS - WIRING
AL 73
HARNESS - WIRING
AL 73
PRINTED CIRCUIT BOARD
AL 41
PRINTED CIRCUIT BOARD
AL 41
HARNESS - WIRING
AL 41
SWITCH - PRESSURE
AL 41
GAUGE - PRESSURE - QUICK PRIMER
AL 41
SYSTEM PRESSURE
AL 71
PRINTED CIRCUIT BOARD
Z REDIRECT
Z REDIRECT
LEDS DO NOT WORK
PRINTED CIRCUIT BOARD
BLANK FOR FUSE F2
Z REDIRECT
OVERHEAT
HARNESS - WIRING
DHW RADS BEGIN TO HEAT
CARTRIDGE - 3 WAY VALVE
DHW RADS BEGIN TO HEAT 2
VALVE - MOTORIZED
CH OPERATION
VALVE - MOTORIZED
FAN DOES NOT RUN
ACTUATOR - DHW
FAN DOES NOT RUN
GOVERNOR - FLOW
FAN DOES NOT RUN 2
ACTUATOR - DHW
FAN DOES NOT RUN
INLET FILTER - DHW
DHW FLOW SWTICH SECTION
HARNESS - WIRING
BOILER FIRES NO DEMAND
PRINTED CIRCUIT BOARD
BOILER FIRES NO DEMAND
ACTUATOR - DHW
OBSERVATION GAS VALVE TYPE?
PRINTED CIRCUIT BOARD - FUSE BLOWN
BURNER DOES NOT IGNITE 2
PRINTED CIRCUIT BOARD
OPENING BUT WRONG MIX
VALVE - GAS (ADJUSTMENT)
OPENING BUT WRONG MIX 2
VALVE - GAS (ADJUSTMENT)
OVERHEAT
HEAT EXCHANGER - PLATE
OVERHEAT 4
PRINTED CIRCUIT BOARD
TRIPPING EARLY
THERMOSTAT - HIGH LIMIT
FAULT CODE RED SOLID
FAULT CODE - OVERHEAT
DHW COOL RADS COOL
HEAT EXCHANGER ASSEMBLY - WATERWAYS
OPEN CIRCUIT 2 DHW OPERATION
CLOCK WIRES (HARNESS - WIRING)
OPEN CIRCUIT DHW OPERATION
CLOCK WIRES (HARNESS - WIRING)
DHW COOL RADS COOL
HEAT EXCHANGER - PLATE
DHW COOL RADS COOL 2
BURNER ASSEMBLY
DHW COOL RADS COOL 2
CONDENSING HEAT EXCHANGER ASSEMBLY - FLUEWAYS
DHW COOL RADS COOL 3
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL 2
PRINTED CIRCUIT BOARD
DHW COOL RADS COOL
BURNER ASSEMBLY
DHW COOL RADS COOL
CONDENSING HEAT EXCHANGER ASSEMBLY - FLUEWAYS
DHW COOL RADS COOL
PRINTED CIRCUIT BOARD
FAN DOES NOT RUN 3
HARNESS - WIRING
FAN DOES NOT RUN
SWITCH - PRESSURE
FAN DOES NOT RUN
GAUGE - PRESSURE - QUICK PRIMER
FAN DOES NOT RUN
SYSTEM PRESSURE
FAN DOES NOT RUN 3
PRINTED CIRCUIT BOARD
CH OPERATION 3
PRINTED CIRCUIT BOARD
OPENING BUT WRONG MIX 2 POOR IGNITION
VALVE - GAS (ADJUSTMENT)
BURNER DOES NOT IGNITE POOR IGNITION
BURNER ASSEMBLY
BURNER DOES NOT IGNITE POOR IGNITION
CONDENSING HEAT EXCHANGER ASSEMBLY - FLUEWAYS
PASSING ROUND HEAD
CARTRIDGE - 3 WAY VALVE
PASSING TO RADS ROUND
VALVE - MOTORIZED
CH OPERATION COMPACT VERSION
VALVE - MOTORIZED
AL 60
PRINTED CIRCUIT BOARD
OVEREHEAT
PRINTED CIRCUIT BOARD
FIRING FOR NO REASON
PRINTED CIRCUIT BOARD
FAULT CODE PRESENT
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
DISPLAY / LEDS DO NOT ILLUMINATE
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
BOILER ATTEMPTS TO FIRE AFTER SELF CHECK COMPLETE - NO DEMAND PRESENT
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
1 FLOW RESTRICTOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
2 FLOW SENSOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
3 DHW INLET FILTER BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS OR INSULATION PANELS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS OR INSULATION PANELS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION
DIFFERENTIAL TEMPERATURE EXCESSIVELY HIGH
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS OR INSULATION PANELS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BURNER IGNITES BUT BAFFLES OR IS NOISY
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS OR INSULATION PANELS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
1 FLOW RESTRICTOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
2 FLOW SENSOR BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
3 DHW INLET FILTER BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM INSPECTION DHW FLOW COMPONENTS
BOILER GOES TO A FAULT BEFORE 80 °C
CHARACTERISTIC TEST FROM OBSERVATION CH - OVERHEAT OCCUR
TEMPERATURE EXCEEDS 88 °C BURNER REMAINS LIT
CHARACTERISTIC TEST FROM OBSERVATION CH - OVERHEAT OCCUR
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION
DIFFERENTIAL TEMPERATURE EXCESSIVELY HIGH
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS OR INSULATION PANELS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS OR INSULATION PANELS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
PRESSURE ON GAUGE OK BUT DOES NOT CHANGE WHEN WATER ADDED
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM OBSERVATION PRESSURE SYSTEM
FAN RUNS CONTINUOUSLY AT HIGH SPEED
CHARACTERISTIC TEST FROM OBSERVATION BOILER SELF CHECK
BURNER IGNITES BUT IGNITION POOR (HEAVY / DELAYED / EXPLOSIVE / SLOW)
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH
BURNER UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS OR INSULATION PANELS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
BOILER DOES NOT RESPOND TO CH DEMAND
CHARACTERISTIC TEST FROM CH OPERATION
BOILER REACHES TEMPERATURE - RADIATORS DO NOT HEAT OR ONLY GET WARM
CHARACTERISTIC TEST FROM CH OPERATION
BOILER TEMPERATURE AND SYSTEM TEMPERATURE LOW - BOILER REMAINS LIT
CHARACTERISTIC TEST FROM CH OPERATION
EXCESSIVE SYSTEM PRESSURE RISE AS SYSTEM HEATS
CHARACTERISTIC TEST FROM CH OPERATION
DHW COOL - RADIATORS REMAIN COOL OR DO NOT INCREASE IN TEMPERATURE
CHARACTERISTIC TEST FROM DHW OPERATION
DHW COOL - RADIATORS BEGIN TO HEAT OR INCREASE IN TEMPERATURE
CHARACTERISTIC TEST FROM DHW OPERATION
DHW TOO HOT
CHARACTERISTIC TEST FROM DHW OPERATION
DHW RUNS HOT THEN COOL
CHARACTERISTIC TEST FROM DHW OPERATION
03/01/2019 12:24:39 1811_1_50_1 22/01/2019 14:17:09
04/01/2019 14:26:21
RESISTANCE DHW FLOW SWITCH AND HARNESS - DEMAND
REMOVE CONNECTOR X16 FROM THE PCB
HOT WATER TAP ON WITH 3 L/MIN FLOW RATE
VOLTAGE PUMP AT PCB
{GAINPCBACS}
VOLTAGE GAS VALVE AT PCB
{GAINPCBACS}
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
RESISTANCE FUSED SPUR
REMOVE FUSE FROM FUSED SPUR
FUSE FURTHER INVESTIGATION - FUSED SPUR
THE INFORMATION PROV
FUSE FURTHER INVESTIGATION - MAINS INPUT
THE INFORMATION PROV
FUSE FURTHER INVESTIGATION - F1 PCB FUSE
THE INFORMATION PROV
RESISTANCE PUMP AND HARNESS
REMOVE CONNECTOR CN5 FROM THE PCB
RESISTANCE PUMP
REMOVE PUMP ELECTRICAL COVER
REMOVE ELECTRICAL CONNECTIONS FROM PUMP ASSEMBLY
RESISTANCE FAN
REMOVE POWER ELECTRICAL CONNECTOR FROM FAN ASSEMBLY
RESISTANCE SPARK GENERATOR
REMOVE ELECTRICAL CONNECTOR TO SPARK GENERATOR.
RESISTANCE DIVERTER VALVE ACTUATOR
REMOVE ELECTRICAL CONNECTOR TO DIVERTER ACTUATOR
RESET APPLIANCE
ENSURE NO DEMANDS ARE PRESENT
ENSURE BOILER IS COOL
RESISTANCE OVERHEAT STAT & HARNESS
REMOVE CONNECTOR X9 FROM THE PCB
RESISTANCE OVERHEAT STAT
REMOVE THE WIRES FROM THE OVERHEAT THERMOSTAT
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE THE WIRES FROM THE LWPS
VOLTAGE SPARK GENERATOR AT PCB
{GAINPCBACS}
TEMPERATURE FLOW PIPE - FROST PROTECTION
ATTACH FGA TEMPERATURE SENSOR TO THE BOILER'S FLOW PIPE
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE DHW FLOW SWITCH AND HARNESS - NO DEMAND
REMOVE CONNECTOR X16 FROM THE PCB
ENSURE NO DEMANDS
RESISTANCE DHW FLOW SWITCH - DEMAND
DISCONNECT 1X ELECTRICAL CONNECTOR TO THE DHW FLOW SWITCH
HOT WATER TAP ON WITH 3 L/MIN FLOW RATE
RESISTANCE GAS VALVE HARNESS
REMOVE CONNECTOR CN3 FROM THE PCB & ELECTRICAL CONNECTOR FROM GAS VALVE
RESISTANCE RECTIFICATION HARNESS
REMOVE CONNECTOR FA2 FROM THE PCB
RESISTANCE TIMER
REMOVE THE WIRES FROM TERMINAL 1 AND 4 OF THE TIMER
RESISTANCE TIMER AND HARNESS
TIMER SET TO ON POSITION
REMOVE THE 2 BLACK WIRES (LABELLED "BLACK") FROM THEIR TERMINALS
RESISTANCE TIMER
REMOVE THE WIRES FROM TERMINAL 1 AND 4 OF THE TIMER
RESISTANCE TIMER AND HARNESS
TIMER SET TO ON POSITION
REMOVE THE 2 BLACK WIRES (LABELLED "BLACK") FROM THEIR TERMINALS
RESISTANCE TIMER
REMOVE THE WIRES FROM TERMINAL 1 AND 4 OF THE TIMER
RESISTANCE TIMER
REMOVE THE WIRES FROM TERMINAL 1 AND 4 OF THE TIMER
VOLTAGE PUMP AT PCB
{GAINPCBACS}
OBSERVATION FAN RUNS (AL 34)
CH & DHW TEMPERATURE CONTROLS SET TO MAX
ENSURE BOILER IS COOL
INFORMATION UHT / CPA
AL 21 FAULT CODE MEA
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
RESISTANCE DHW TEMPERATURE SENSOR HARNESS
REMOVE ELECTRICAL CONNECTOR TO DHW TEMPERATURE SENSOR
& CONNECTOR X16 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR X9 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR X9 FROM THE PCB
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE THE WIRES FROM THE LWPS
FUSE FURTHER INVESTIGATION - F2 PCB FUSE
THE INFORMATION PROV
VOLTAGE DIVERTER VALVE AT PCB DHW
{GAINPCBACS}
VOLTAGE DIVERTER VALVE AT PCB CH
{GAINPCBACS}
INSPECTION DHW FLOW COMPONENTS
DRAIN THE DOMESTIC H
RESISTANCE DHW FLOW SWITCH - NO DEMAND
DISCONNECT 1X ELECTRICAL CONNECTOR TO THE DHW FLOW SWITCH
ENSURE NO DEMAND
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER (FAULT CODE)
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
RESISTANCE TIMER AND HARNESS
TIMER SET TO ON POSITION
REMOVE THE 2 BLACK WIRES (LABELLED "BLACK") FROM THEIR TERMINALS
RESISTANCE TIMER
REMOVE THE WIRES FROM TERMINAL 1 AND 4 OF THE TIMER
RESISTANCE TIMER
REMOVE THE WIRES FROM TERMINAL 1 AND 4 OF THE TIMER
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
RESISTANCE LOW WATER PRESSURE SWITCH
REMOVE THE WIRES FROM THE LWPS
VOLTAGE DIVERTER VALVE AT PCB DHW
{GAINPCBACS}
VOLTAGE DIVERTER VALVE AT PCB CH
{GAINPCBACS}
VOLTAGE MAINS INPUT - PCB
{GAINPCBACS}
INSPECTION DHW FLOW COMPONENTS
DRAIN THE DOMESTIC H
VOLTAGE FAN - PERMANENT SUPPLY
REMOVE 4 WIRE CABLE FROM FAN ASSEMBLY
ENSURE NO DEMANDS
FAN RUNS - SIGNAL CONTROL DISCONNECTED
REMOVE SIGNAL CONTROL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
VOLTAGE PUMP AT PUMP
GAIN ACCESS TO THE PUMP TERMINALS
OBSERVATION GAS VALVE OPENS
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
ENSURE NO DEMANDS
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
OBSERVATION SPARKING OCCURS
REMOVE ELECTRODE LEA
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
RESISTANCE GAS VALVE HARNESS
REMOVE CONNECTOR CN3 FROM THE PCB & ELECTRICAL CONNECTOR FROM GAS VALVE
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
RESISTANCE RECTIFICATION TO EARTH AT PCB
REMOVE CONNECTOR FA2 FROM THE PCB
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
INSPECTION EXPANSION VESSEL PRESSURE
DRAIN BOILER PRIMARY SYSTEM WATER
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE FUSE F1
REMOVE FUSE FROM PCB
RESISTANCE FUSE - MAINS INPUT
REMOVE MAINS INPUT FUSE FROM TERMINAL BLOCK
RESISTANCE FAN AND HARNESS
REMOVE CONNECTOR CN1 FROM THE PCB
RESISTANCE SPARK GENERATOR AND HARNESS
REMOVE CONNECTOR CN2 FROM THE PCB
RESISTANCE DIVERTER VALVE ACTUATOR & HARNESS
REMOVE CONNECTOR CN5 FROM THE PCB
FAULT CODE / NOTIFICATION
PLEASE SELECT THE APPROPRIATE FAULT CODE FROM THE LIST BELOW:
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
RESISTANCE FAN HARNESS
REMOVE SPEED CONTROL CONNECTOR FROM FAN ASSEMBLY
RESISTANCE SPARK GENERATOR HARNESS
REMOVE CN2 FROM THE PCB
DISCONNECT FAN SPEED CONTROL CONNECTOR
REMOVE FAN SPEED CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
OBSERVATION CONTROL KNOB TO DHW ONLY BOILER FIRES?
SELECTOR SWITCH TO DHW ONLY POSITION
DISCONNECT EXTERNAL CONTROLS
DISCONNECT THE EXTERNAL CONTROLS FROM THE MAIN
TERMINAL STRIP CONNECTIONS 2-3 AND MAKE SAFE
RESISTANCE IGNITION ELECTRODE
REMOVE THE IGNITION ELECTRODE FROM THE BURNER DOOR ASSEMBLY
RESISTANCE RECTIFICATION HARNESS
REMOVE CONNECTOR FA2 FROM THE PCB
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
RESISTANCE DETECTION ELECTRODE
DISCONNECT THE RECTI
RESISTANCE DETECTION ELECTRODE
DISCONNECT THE RECTI
OBSERVATION LINK EXTERNAL CONTROLS
REMOVE THE WRING FRO
RESISTANCE HARNESS TO EXTERNAL CONTROLS WITH LINK
REMOVE CONNECTOR CN1 FROM THE PCB
RESISTANCE TIMER AND HARNESS
TIMER SET TO ON POSITION
REMOVE THE 2 BLACK WIRES (LABELLED "BLACK") FROM THEIR TERMINALS
OBSERVATION LINK EXTERNAL CONTROLS
REMOVE THE WRING FRO
RESISTANCE HARNESS TO EXTERNAL CONTROLS WITH LINK
REMOVE CONNECTOR CN1 FROM THE PCB
RESISTANCE TIMER AND HARNESS
TIMER SET TO ON POSITION
REMOVE THE 2 BLACK WIRES (LABELLED "BLACK") FROM THEIR TERMINALS
RESISTANCE GAS VALVE HARNESS
REMOVE CONNECTOR CN3 FROM THE PCB & ELECTRICAL CONNECTOR FROM GAS VALVE
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
VOLTAGE PUMP AT PUMP
GAIN ACCESS TO THE PUMP TERMINALS
RESISTANCE FAN HARNESS
REMOVE SPEED CONTROL CONNECTOR FROM FAN ASSEMBLY
VOLTAGE DC (HALL SENSOR) AT PCB
REFIT 4 WIRE FAN CABLE TO FAN ASSEMBLY
FAN RUNS - SIGNAL CONTROL DISCONNECTED
REMOVE SIGNAL CONTROL CONNECTOR FROM FAN ASSEMBLY AND MAKE SAFE
RESET APPLIANCE (SYSTEM PRESSURE)
ENSURE NO DEMANDS ARE PRESENT
ENSURE BOILER IS COOL
RESISTANCE IGNITION LEAD
REMOVE THE IGNITION LEAD FROM THE SPARK GENERATOR AND IGNITION ELECTRODE
RESISTANCE FUSE F2
REMOVE FUSE FROM PCB
RESISTANCE FLUE OVERHEAT THERMOSTAT
REMOVE THE WHITE WIR
OBSERVATION DIVERTER VALVE OPERATION DHW
REMOVE DIVERTER VALVE HEAD FROM THE APPLIANCE AND PLACE IN A SAFE LOCATION
RESISTANCE ACTUATOR HARNESS
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
REMOVE CONNECTOR CN5 FROM THE PCB
OBSERVATION DIVERTER VALVE OPERATION CH
REMOVE DIVERTER VALVE HEAD FROM THE APPLIANCE AND PLACE IN A SAFE LOCATION
RESISTANCE ACTUATOR HARNESS
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
REMOVE CONNECTOR CN5 FROM THE PCB
RESISTANCE DHW FLOW SWITCH - NO DEMAND (WATER ISOLATED)
DISCONNECT 1X ELECTR
RESISTANCE GAS VALVE
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE
RESISTANCE GAS VALVE
REMOVE ELECTRICAL CONNECTOR FROM GAS VALVE
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
TEMPERATURE FLUE GAS
INSERT FGA TEMPERATURE PROBE INTO FLUE SAMPLING POINT
OBSERVATION APPLIANCE TO MAXIMUM TEMP - FAULT CODE REOCCURS?
ATTACH FGA TEMPERATURE CLAMP TO THE FLOW PIPE
RESISTANCE OVERHEAT STAT
REMOVE THE WIRES FROM THE OVERHEAT THERMOSTAT
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
TEMPERATURE DIFFERENTIAL PLATE HEAT EXCHANGER
ATTACH TEMPERATURE PROBES TO FLOW & RETURN
PIPES AS INDICATED BY THE RED ARROWS
INSPECTION NON-RETURN VALVE
ENSURE BOILER IS COO
OBSERVATION LINK EXTERNAL CONTROLS
REMOVE THE WRING FRO
RESISTANCE HARNESS TO EXTERNAL CONTROLS WITH LINK
REMOVE CONNECTOR CN1 FROM THE PCB
RESISTANCE TIMER AND HARNESS
TIMER SET TO ON POSITION
REMOVE THE 2 BLACK WIRES (LABELLED "BLACK") FROM THEIR TERMINALS
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
VOLTAGE FAN - DEMAND
REMOVE 4 WIRE CABLE FROM FAN ASSEMBLY
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE DHW TEMPERATURE SENSOR & HARNESS
REMOVE CONNECTOR X16 FROM THE PCB
VOLTAGE FAN - PERMANENT SUPPLY
REMOVE 4 WIRE CABLE FROM FAN ASSEMBLY
ENSURE NO DEMANDS
RESISTANCE FAN HARNESS
REMOVE SPEED CONTROL CONNECTOR FROM FAN ASSEMBLY
VOLTAGE FAN - PERMANENT SUPPLY
REMOVE 4 WIRE CABLE FROM FAN ASSEMBLY
ENSURE NO DEMANDS
VOLTAGE FAN - NO DEMAND
REMOVE 4 WIRE CABLE FROM FAN ASSEMBLY
ENSURE NO DEMANDS
OBSERVATION MAX AND MIN FAN SPEEDS
REMOVE SELECTOR SWITCH CONTROL KNOB
ENSURE NO DEMANDS
OBSERVATION MAX AND MIN FAN SPEEDS
REMOVE SELECTOR SWITCH CONTROL KNOB
ENSURE NO DEMANDS
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
OBSERVATION HEATING FAN SPEED
REMOVE SELECTOR SWITCH CONTROL KNOB
ENSURE NO DEMANDS
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS INLET PRESSURE TEST POINT
RESISTANCE IGNITION LEAD
REMOVE THE IGNITION LEAD FROM THE SPARK GENERATOR AND IGNITION ELECTRODE
RESISTANCE IGNITION ELECTRODE
REMOVE THE IGNITION ELECTRODE FROM THE BURNER DOOR ASSEMBLY
INSPECTION BURNER / HEAT EXCHANGER FLUEWAYS
REMOVE BURNER ASSEMBLY FROM BOILER
OBSERVATION IGNITION FAN SPEED
REMOVE SELECTOR SWITCH CONTROL KNOB
ENSURE NO DEMANDS
INSPECTION INJECTOR
REMOVE THE PIPE RUNNING FROM THE GAS VALVE TO THE COMBUSTION CHAMBER AND REMOVE THE INJECTOR FROM IT
INSPECTION INJECTOR
REMOVE THE PIPE RUNNING FROM THE GAS VALVE TO THE COMBUSTION CHAMBER AND REMOVE THE INJECTOR FROM IT
INSPECTION INJECTOR
REMOVE THE PIPE RUNNING FROM THE GAS VALVE TO THE COMBUSTION CHAMBER AND REMOVE THE INJECTOR FROM IT
INSPECTION INJECTOR
REMOVE THE PIPE RUNNING FROM THE GAS VALVE TO THE COMBUSTION CHAMBER AND REMOVE THE INJECTOR FROM IT
INSPECTION INJECTOR
REMOVE THE PIPE RUNNING FROM THE GAS VALVE TO THE COMBUSTION CHAMBER AND REMOVE THE INJECTOR FROM IT
INSPECTION INJECTOR
REMOVE THE PIPE RUNNING FROM THE GAS VALVE TO THE COMBUSTION CHAMBER AND REMOVE THE INJECTOR FROM IT
RESISTANCE ACTUATOR HARNESS (COMPACT)
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
REMOVE CONNECTOR CN5 FROM THE PCB
RESISTANCE ACTUATOR HARNESS (COMPACT)
REMOVE ELECTRICAL CONNECTOR FROM DIVERTER VALVE (DV) ACTUATOR
REMOVE CONNECTOR CN5 FROM THE PCB
INSPECTION BY-PASS VALVE
ENSURE BOILER IS COO
RESISTANCE FLOW TEMPERATURE SENSOR
REMOVE CONNECTORS FROM FLOW SENSOR
RESISTANCE RETURN TEMPERATURE SENSOR
REMOVE CONNECTORS FROM RETURN SENSOR
RESISTANCE TIMER AND HARNESS (NO DEMAND)
TIMER SET TO OFF POSITION
REMOVE THE 2 BLACK WIRES (LABELLED "BLACK") FROM THEIR TERMINALS