Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove power electrical connector from fan assembly
Measurement:
Test 1. Measure for resistance across pins 1 and 3 of fan connection.
Expected resistance greater than 1MOhm.
Test 2. Measure for resistance across pin 1 and 2 fan connection.
Expected resistance greater than 1MOhm.
(O.L is acceptable because this is greater than 1MOhm)
Are the resistances measured as expected?
Expected resistance greater than 1MOhm.
Test 2. Measure for resistance across pin 1 and 2 fan connection.
Expected resistance greater than 1MOhm.
(O.L is acceptable because this is greater than 1MOhm)
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary