Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove pump electrical cover
Remove electrical connections from pump assembly
Remove electrical connections from pump assembly
Measurement:
Test 1. Measure for resistance across live and neutral terminals of the pump.
Expect approximately 164 ohms or greater.
Test 2. Measure for resistance across live and earth terminals of the pump.
Expected resistance greater than 1Mohm.
(O.L is acceptable because it is greater than 1MOhm)
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary