Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Remove selector switch control knob
Ensure NO demands
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Reset the boiler / cancel pump purge as necessary.
Test 1:
Using a small flat blade screwdriver turn the maximum trimmer slightly - this will cause the display to show the fan speed in multiples of 1000 i.e. 5.2 would be 5200rpm. Check the value displayed corresponds to the table for the appliance you are working on.
Test 2:
Using a small flat blade screwdriver turn the minimum trimmer slightly - this will cause the display to show the fan speed in multiples of 1000 i.e. 5.2 would be 5200rpm. Check the value displayed corresponds to the table for the appliance you are working on.
Are the fan speeds set correctly as per the table?
Note:
Leaving the maximum or minimum trimmers for 10 seconds or greater returns the display to normal.