Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X16 from the PCB
Hot water tap ON with 3 l/min flow rate
Hot water tap ON with 3 l/min flow rate
Measurement:
Measure the resistance between the two purple wires at connector X16.
Expect continuity / zero resistance.
Is the resistance measured as expected?
Expect continuity / zero resistance.
Is the resistance measured as expected?

Isolate as per TOPs P4
and refit as necessary