POTTERTON LYNX
G.C. NUMBER 47 590 0
CENTRAL HEATING OPERATION
CENTRAL HEATING SELE
HOT WATER OPERATION
HOT WATER THERMOSTAT
HIGH FLAME LED STATE
BOILER ON
LOW FLAME LED STATE
BOILER ON
IGNITION LED STATE
SWITCH BOILER OFF THEN ON
DEMAND AND MINIMUM TEMPERATURE LEDS STATE
BOILER ON
SET SUMMER/WINTER SWITCH TO THE SUMMER POSITION
DC POWER SUPPLY 2 MEASUREMENT
BOILER ON
SUMMER/WINTER SWITCH SET TO THE WINTER POSITION
DC POWER SUPPLY 1 MEASUREMENT
{GAINPCBACS}
BOIL
POTTERTON LYNX
G.C. NUMBER 47 590 0
SYSTEM CHECKS
PLEASE ENSURE THE FOLLOWING SYSTEM CHECKS ARE COMPLETED
ELECTRICAL SAFETY CHECKS
ELECTRICAL SAFETY CHECKS
NO LEDS LIGHT (2)
DIVERTER VALVE MICROSWITCH ASSEMBLY
HIGH FLAME LED STATE (3)
MODUREG COIL (GV3)
CENTRAL HEATING OPERATION
CH WATER TEMPERATURE SENSOR
LOW FLAME LED STATE (3)
GAS VALVE AND FIRST SOLENOID VALVE
HIGH FLAME
GAS VALVE AND FIRST SOLENOID VALVE
SYSTEM CHECKS
SYSTEM CHECKS
DC POWER SUPPLY 1 MEASUREMENT
PUMP OVERRUN THERMOSTAT
DC POWER SUPPLY 1 MEASUREMENT
FUSE F1
DC POWER SUPPLY 2 MEASUREMENT
DHW TEMPERATURE SENSOR
HOT WATER OPERATION
DHW TEMPERATURE SENSOR
HIGH FLAME LED STATE
DISTRIBUTION BOARD
AIR FLOW SENSOR MEASUREMENT - MOVING AIR
AIR FLOW SENSOR
AIR FLOW SENSOR - STILL AIR OPERATION
FULL SEQUENCE CONTROL BOARD
DC POWER SUPPLY 2 MEASUREMENT
FUSE F2
MINIMUM CH TEMPERATURE, LED LIGHTS
DIVERTER VALVE
NO LEDS LIGHT
DIVERTER VALVE
NO LEDS LIGHT (3)
DIVERTER VALVE MICROSWITCH ASSEMBLY
IGNITION LED STATE
PUMP OVERRUN THERMOSTAT
IGNITION LED STATE
PUMP
IGNITION LED STATE
DHW OVERHEAT (LIMIT) THERMOSTAT
WATER FLOW INTERLOCK SWITCH
AIR FLOW SENSOR
LOW FLAME SEEN, BUT LED DOES NOT LIGHT
SENSING ELECTRODE AND LEAD
OVERHEAT THERMOSTAT
CENTRAL HEATING OVERHEAT THERMOSTAT
CENTRAL HEATING OPERATION
DISTRIBUTION BOARD
LOW FLAME LED STATE (2)
GAS VALVE AND FIRST SOLENOID VALVE
LOW FLAME LED STATE (4)
GAS VALVE AND FIRST SOLENOID VALVE
HIGH FLAME LED STATE (2)
MODUREG COIL (GV3)
HOT WATER OPERATION
DISTRIBUTION BOARD
AIR FLOW SENSOR MEASUREMENT - MOVING AIR
FULL SEQUENCE CONTROL BOARD
DC POWER SUPPLY 1 MEASUREMENT
DISTRIBUTION BOARD
DC POWER SUPPLY 2 MEASUREMENT
DISTRIBUTION BOARD
IGNITION LED STATE
FAN ASSEMBLY AND FLUE SYSTEM
DEMAND AND MINIMUM TEMPERATURE LEDS STATE
DISTRIBUTION BOARD
MINIMUM CH TEMPERATURE, LED LIGHTS (1)
DIVERTER VALVE MICROSWITCH ASSEMBLY
MINIMUM CH TEMPERATURE, LED LIGHTS (2)
DIVERTER VALVE MICROSWITCH ASSEMBLY
NO LEDS LIGHT (1)
DIVERTER VALVE MICROSWITCH ASSEMBLY
IGNITION LED STATE
WATER FLOW SWITCH
IGNITION LED STATE
MODULATING BOARD
LOW FLAME SEEN, BUT LED DOES NOT LIGHT
FULL SEQUENCE CONTROL BOARD
BOILER DOES NOT LIGHT UP, NO LED
SPARK IGNITION ELECTRODE AND LEAD
BOILER DOES NOT LIGHT UP, NO LED
FULL SEQUENCE CONTROL BOARD
LOW FLAME LED STATE (1)
GAS VALVE AND FIRST SOLENOID VALVE
HIGH FLAME LED STATE (1)
MODULATING BOARD
CENTRAL HEATING OPERATION
MODULATING BOARD
ALL TEMPERATURE LEDS CH AND DHW LIGHT, NO DEMAND LED
CHARACTERISTIC TEST FROM DEMAND AND MINIMUM TEMPERATURE LEDS STATE
MINIMUM CH TEMPERATURE, LED LIGHTS
CHARACTERISTIC TEST FROM DEMAND AND MINIMUM TEMPERATURE LEDS STATE
NO LEDS LIGHT
CHARACTERISTIC TEST FROM DEMAND AND MINIMUM TEMPERATURE LEDS STATE
LOW FLAME SEEN, BUT LED DOES NOT LIGHT
CHARACTERISTIC TEST FROM LOW FLAME LED STATE
BOILER DOES NOT LIGHT UP, NO LED
CHARACTERISTIC TEST FROM LOW FLAME LED STATE
SPARK GENERATOR CLICKS BUT NO SPARK AT ELECTRODE
CHARACTERISTIC TEST FROM SPARK IGNITION
NO SPARK FROM ELECTRODE, NO CLICK FROM SPARK GENERATOR
CHARACTERISTIC TEST FROM SPARK IGNITION
RESISTANCE IS GREATER THAN 30 OHMS
CHARACTERISTIC TEST FROM GAS VALVE GV1/2 RESISTANCE MEASUREMENT
RESISTANCE IS LESS THAN 20 OHMS
CHARACTERISTIC TEST FROM GAS VALVE GV1/2 RESISTANCE MEASUREMENT
06/12/2012 11:35:28 1303_1_50_1 10/01/2013 13:33:32
06/12/2012 11:47:48
DIVERTER VALVE CHECK
PLASTIC COVER OF DIVERTER VALVE REMOVED
ALL HOT TAPS CLOSED
SHUTDOWN RELAY OPERATION CHECK
{GAINPCBACS}
BOILER ON
SUMMER/WINTER SWITCH SET TO WINTER
SYSTEM CALLING FOR HEAT
WATER FLOW INTERLOCK SWITCH
{GAINPCBACS}
BOILER ON
WATER PUMP MAINS VOLTAGE MEASUREMENT
{GAINPCBACS}
BOILER ON
FAN VOLTAGE MEASUREMENT
{GAINPCBACS}
BOILER ON
GAS VALVE GV3 SOLENOID RESISTANCE MEASUREMENT
DISCONNECT ONE OF THE LEADS ON GV3
DHW TEMPERATURE SENSOR MEASUREMENT
{GAINPCBACS}
BOILER ON
CENTRAL HEATING SENSOR MEASUREMENT
{GAINPCBACS}
BOILER ON
SUMMER/WINTER SWITCH SET TO WINTER
SYSTEM CALLING FOR HEAT
PUMP OVERRUN THERMOSTAT
DISCONNECT THE PLUG D28 - D31 FROM THE FULL SEQUENCE CONTROL BOARD
DHW TEMPERATURE SENSOR MEASUREMENT
{GAINPCBACS}
BOILER ON
AC MICROSWITCH CHECK
{GAINPCBACS}
BOILER ON
MAKE SURE THAT ANY PROGRAMMER/TIMERS ARE ON
DIVERTER VALVE CHECK
PLASTIC COVER OF DIVERTER VALVE REMOVED
ALL HOT TAPS CLOSED
AC MICROSWITCH CHECK
{GAINPCBACS}
BOILER ON
MAKE SURE THAT ANY PROGRAMMER/TIMERS ARE ON
DHW TEMPERATURE SENSOR MEASUREMENT
{GAINPCBACS}
BOILER ON
FAN RUNS
BOILER ON
DOMESTIC HOT WATER TEMPERATURE (DHW)
DISCONNECT THERMOSTAT ELECTRICAL PLUG-IN CONNECTOR D32 & D33 ON DISTRIBUTION BOARD
WATER PUMP (RUNNING) FUNCTION
BOILER ON
REMOVE
AIR FLOW SENSOR MEASUREMENT - MOVING AIR
DISCONNECT CONNECTOR D1 - D12 FROM FULL SEQUENCE CONTROL BOARD
AIR FLOW SENSOR MEASUREMENT - MOVING AIR
DISCONNECT CONNECTOR D1 - D12 FROM FULL SEQUENCE CONTROL BOARD
SPARK IGNITION
BOILER ON
SYSTEM CALLING FOR HEAT
GAS VALVES 1/2 VOLTAGE
{GAINPCBACS}
BOILER ON
SYSTEM CALLING FOR HEAT
GAS VALVE GV3 VOLTAGE MEASUREMENT
{GAINPCBACS}
BOILER ON
SYSTEM CALLING FOR HEAT
CENTRAL HEATING TEMPERATURE SELECTOR CHECK
{GAINPCBACS}
BOILER ON
SUMMER/WINTER SWITCH SET TO WINTER
SYSTEM CALLING FOR HEAT
System Information
- Total Tests: 97
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control