Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Boiler On
Boiler On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between:
D15 (Purple wire) and D14 (Purple wire) on distribution board.
Voltage should be between 3 - 8V dc dependent on the Hot Water flow temperature.
D15 (Purple wire) and D14 (Purple wire) on distribution board.
Voltage should be between 3 - 8V dc dependent on the Hot Water flow temperature.

Isolate as per TOPs P4
and refit as necessary