Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Boiler On
Boiler On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between D26 (+ve) and D25 (-ve) on distribution board.
Water Flow Interlock has closed if the voltage is approximately 0V.
Water Flow Interlock has closed if the voltage is approximately 0V.

Isolate as per TOPs P4
and refit as necessary