Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
4726737 FERROLI DOMICOMPACT F24 B
WARNING - IMPORTA
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
FAN RUNS BURNER IGNITES AND ESTABLISHES DHW DEMAND
UNDO OUTLET PRESSURE TEST POINT
ATTACH U GAUGE TO OUTLET PRESSURE TEST POINT
OPERATION DHW
DHW TEMPERATURE CONT
PUMP RUNS CENTRAL HEATING DEMAND
PREHEAT OFF (ECO SHOWING IN DISPLAY)
CH THERMOSTAT TURNED TO MID POSITION
OPERATION CH
PREHEAT SWITCHED OFF
BOILER FIRES WITH NO DEMAND
OUTSIDE MODEL
SAFETY OVERHEAT LOCKOUT
OUT OF MODEL
DHW FAULTY SENSOR LOCKOUT
OUT OF MODEL
PRIMARY FAULTY SENSOR LOCKOUT
OUT OF MODEL
OPERATION OF SAFETY STATS AND HARNESS AT TEMP
ATTACH FGA TEMPERATU
F5 FAULT CODE
OUT OF MODEL
F2 FAULT CODE
OUT OF MODEL
FAULT CODE F37
OUT OF MODEL
OBSERVATION PREHEAT IS IT SATISFACTORY
ENSURE NO CH DEMAND OR NO DHW DEMAND
BLOWN STANDBY MODE
FUSE MAIN PCB F2
POOR FLOW RATE
SERVICE VALVE INLET (WATER INLET)
BOILER TEMP LOW SYSTEM TEMP LOWOPERATION DHW DHW COOL RADS COOL
GAS PRESSURE INLET
COOL HOT WATER
GAS VALVE - SIEMENS
OVERHEATOVERHEAT FURTHERBOILER OVER HEAT
THERMOSTAT 100 DEG C
OVERHEATOVERHEAT FURTHER
PUMP ASSEMBLY
OVERHEAT
BURNER ASSEMBLY
OVERHEAT
COMBUSTION CHAMBER
OVERHEAT 2
SWITCH - FLOW
TURNED OFF
FLOW RETURN VALVE/S
NO SHUT DOWN
GAS VALVE - SIEMENS
OVERHEAT
SWITCH - FLOW
OVERHEATOVERHEAT FURTHER
SENSOR 10K NTC
OVERHEATOVERHEAT FURTHER
SENSOR - DHW C/W BRACKET
NO HW
SWITCH - FLOW
NO PUMPNO EXTERNAL CONTROL NO PUMP
HARNESS (MAIN)
NO PUMP
HARNESS (MAIN)
NO CH HW STUCK ON
SWITCH - FLOW
NOT SWITCHING OFF
SWITCH - FLOW
LINK TO F5
Z DIRECTION CHOICE OR CONTINUE
NOT MODULATING UP
SENSOR - DHW C/W BRACKET
NOT MODULATING UP
SENSOR 10K NTC
HIGH RESISTANCE CAUSING BLANK DISPLAY
GAS VALVE - SIEMENS
NO FAN
TUBE IMPULSE AIR PRESSURE
INOPERABLE
SWITCH - FLOW
SYSTEM PRESSURE
SYSTEM PRESSURE
FAN RUNS DHW
SENSOR 10K NTC
SENSOR TEMP DHW
HARNESS (MAIN)
FAN RUNS
KIT - THERMOSTAT 100 DEG - SECURITY
NO FAN
THERMOSTAT 100 DEG C
APSF5
HARNESS (MAIN)
BLOCKED OR DAMAGED FAN RUNS SPARKING DOES NOT OCCURDHW NOT THEN COLDF5 FAULT CODEF5 FAULT
TUBE IMPULSE AIR PRESSURE
BLOCKED OR DAMAGEDDHW NOT THEN COLDF5 FAULT CODEF5 FAULT
FAN ASSEMBLY (VENTURI)
NO AIR PRESSUREDHW NOT THEN COLDF5 FAULT CODEF5 FAULTF5
EXCHANGER - HEAT MAIN (FLUE WAYS)
NO APS PROVINGDHW NOT THEN COLDF5 FAULT CODEF5 FAULTF5
EXCHANGER - HEAT - SECONDARY (FLUEWAYS)
NO FANF5
TUBE IMPULSE AIR PRESSURE
DHW RUNS HOT COLD
SENSOR 10K NTC - ADJUSTMENT
DISPLAY
PCB
MECHANICAL PHYSICAL OPERATION
FAN ASSEMBLY
BURNER IGNITES BUT DOES NOT ESTABLISH
GAS PRESSURE INLET
POOR SUPPLY
GAS PRESSURE INLET
NEW MODELBLOCKED OR DAMAGED
BURNER ASSEMBLY
GAP DAMAGE
ELECTRODE - IGNITION
BLOCKED OR DAMAGED FAN RUNS SPARKING DOES NOT OCCUR
TUBE IMPULSE AIR PRESSURE
BLOCKED OR DAMAGED
FAN ASSEMBLY (VENTURI)
FAN RUNS SPARKING DOES NOT OCCUR
FAN ASSEMBLY
NO SPARK
SPARK GAP
CASE REMOVAL
Z DIRECTION CHOICE OR CONTINUE
DHW COOL RADS COLD NO DEMAND
SENSOR - DHW C/W BRACKET
DHW TOO HOT
SENSOR - DHW C/W BRACKET
NEW MODEL FLUEWAYS
EXCHANGER - HEAT MAIN
NO AIR PRESSURE
EXCHANGER - HEAT MAIN (FLUE WAYS)
NO RECTIFICATION
TRAP - CONDENSATE
NO SPARK
LEAD - IGNITION & FLAME SENSING
DHW HOT THEN COLD
SENSOR - DHW C/W BRACKET
DHW RUNS HOT THEN COLD
SENSOR 10K NTC
NO SPARK
PCB
FAN RUNS
PCB
BURNER LIGHTS DOESNT ESTABLISH
BURNER ASSEMBLY
BURNER BAFFLES
EXCHANGER - HEAT - SECONDARY (FLUEWAYS)
NO APS PROVING
EXCHANGER - HEAT - SECONDARY (FLUEWAYS)
DHW COOL
SENSOR 10K NTC
HOT THEN COLD
GAS VALVE - SIEMENS
DHW TOO HOT
GAS VALVE - SIEMENS
DHW COOL
PCB
BLOCKED OR DAMAGED FAN RUNS SPARKING DOES NOT OCCURDHW NOT THEN COLD
TUBE IMPULSE AIR PRESSURE
BLOCKED OR DAMAGEDDHW NOT THEN COLD
FAN ASSEMBLY (VENTURI)
FAN RUNS SPARKING DOES NOT OCCURDHW NOT THEN COLD
FAN ASSEMBLY
NO AIR PRESSUREDHW NOT THEN COLD
EXCHANGER - HEAT MAIN (FLUE WAYS)
NO APS PROVINGDHW NOT THEN COLD
EXCHANGER - HEAT - SECONDARY (FLUEWAYS)
UNDER PRESSURE
EXPANSION VESSEL 8 LITRE
FOR TYPE DIAG PROCEDURE
Z DIRECTION CHOICE OR CONTINUE
BOILER TEMP LOW SYSTEM TEMP LOW
GAS PRESSURE INLET
BOILR SHUTS DOWN PREMATURELY CHOPERATION
PUMP ASSEMBLY
BOILER TO TEMP RADS COOL
PUMP ASSEMBLY
BOILER TEMP LOW SYSTEM LOW
SENSOR 10K NTC
BOILER NOISY CH
SENSOR 10K NTC
FROST
SENSOR 10K NTC
BOILER GOES TO OVERHEATOVERHEAT
THERMOSTAT 100 DEG C
NO PUMP DHWNO DHW PUMPDHW LOCKOUTDHW LOCKOUT
SENSOR - DHW C/W BRACKET
CH LOCKOUT
SENSOR 10K NTC
PUMP
HARNESS (MAIN)
APS
HARNESS (MAIN)
GAS VALVE
HARNESS (MAIN)
OPEN OR SHORT CIRCUITFURTHER INVESTIGATION FUSE F1
GAS VALVE SOLENOID MODULATING
FURTHER INVESTIGATION FUSE F1
PUMP ASSEMBLY
OPEN OR SHORT CIRCUITFURTHER INVESTIGATION FUSE F1F1 OR F2 ON PCB
GAS VALVE SOLENOID MODULATING
FURTHER INVESTIGATION FUSE F1F1 OR F2 ON PCB
PUMP ASSEMBLY
FURTHER INVESTIGATION FUSE F1
FAN ASSEMBLY
FURTHER INVESTIGATION FUSE F1F2
FAN ASSEMBLY
NO CH
SWITCH - FLOW
LOCKOUT
KIT - THERMOSTAT 100 DEG - SECURITY
BLOWN STAND BY MODE AT POWER UP
MAIN FUSE FUSED SPUR F1
UNABLE TO SET
BURNER PRESSURE ADJUSTMENT
F2 F3
GAS VALVE - SIEMENS
FAULT CODES
Z DIRECTION CHOICE OR CONTINUE
F2
GAS VALVE - SIEMENS
F37 FAULT CODE
SYSTEM PRESSURE
F37 FAULT CODE
LOW WATER PRESSURE SWITCH
BOILER GETS TOO COOL
SENSOR 10K NTC
FUSE1
GAS VALVE - SIEMENS
DAMAGED
INJECTOR 1.30 - MAIN
BOILER FIRES NO DEMAND
INTEGRAL CLOCK
BOILER GOES TO OVERHEATOVERHEATOVERHEAT
THERMOSTAT 100 DEG C
LOCKOUTOVERHEAT
KIT - THERMOSTAT 100 DEG - SECURITY
UNABLE TO SET 2
GAS VALVE - SIEMENS
DHW NOISY
GAS VALVE - SIEMENS
FLAME ROLL
BURNER ASSEMBLY
CONTAMINATION COMBSTION AIR
FLUE SEALS
AIR INTAKE CONTAMINATION
COMBUSTION CHAMBER
NO RECTIFICATION
ELECTRODE - IGNITION
NO RETIFICATION
LEAD - IGNITION & FLAME SENSING
NOT LIGHTING
LEAD - IGNITION & FLAME SENSING
BLOWN STANDBY MODE AT POWER UP
FUSE MAIN PCB
FURTHER IN VESTIGATION F3
Z DIRECTION CHOICE OR CONTINUE
DHW COOL
BURNER PRESSURE ADJUSTMENT
MODUREG VOLTAGE
HARNESS (MAIN)
HEAT EXCHANGER PRIMARY
EXCHANGER - HEAT MAIN
SAFETY STATBOILER OVER HEAT
HARNESS (MAIN)
FAN DOES NOT RUN
FAN ASSEMBLY
OVERHEATBOILER OVER HEAT
KIT - THERMOSTAT 100 DEG - SECURITY
FAN ASS
HARNESS (MAIN)
NO PUMP
PCB
FAN NOT RUNNING AND NO LED
FAN ASSEMBLY
FAILS PREHEAT
PCB
FAN DOES NOT RUNF5
FAN ASSEMBLY
FAN ASSF5
HARNESS (MAIN)
MODUREG VOLTAGE
PCB
OVERHEAT INVESTIGATION PAGE
BOILER OVERHEAT
OVERHEAT INVESTIGATION PAGE 2
BOILER OVERHEAT
STUCK ON NO FAN
PRESSURE SWITCH - HUBA
NO FAN
LOW WATER PRESSURE SWITCH
SENSOR PRIMARY FAN RUNS
HARNESS (MAIN)
FAN RUNS DHW DEMAND
SENSOR - DHW C/W BRACKET
NO FAN
PCB
OVER HEAT STAT FAN RUNS
HARNESS (MAIN)
NO AIR FLOWF5
PRESSURE SWITCH - HUBA
F5F5 FAULTF5
FAN ASSEMBLY
NO FANF5
PCB
STUCK ON NO FANF5
PRESSURE SWITCH - HUBA
SPARKING OCCURS BURNER DOES NOT LIGHT
GAS VALVE - SIEMENS
LEAD NO SPARK
ELECTRODE - IGNITION
HIGH_LOW ADJUSTMENT
BURNER PRESSURE ADJUSTMENT
KETTLING
EXCHANGER - HEAT MAIN
BLOCKED OR DAMAGED
FLUE
NO RECTIFICATION
PCB
DHW TOO HOT
PCB
POOR DHW TEMP RISE
EXCHANGER - HEAT MAIN
PUMP RUNS
PUMP ASSEMBLY
NO APS PROVINGDHW HOT THEN COLD
PRESSURE SWITCH - HUBA
NO AIR FLOW
PRESSURE SWITCH - HUBA
EXPANSION CONNECTION
BLOCKAGES
LOW GAS RATE CH OPERATION
INJECTOR 1.30 - MAIN
CH OPERATION NOISY
EXCHANGER - HEAT MAIN
BOILER FIRES NO DEMAND
FROST PROTECTION
BOILER NOISY
PCB
FLUE OVERHEAT
HARNESS (MAIN)
DHW THERMISTOR
HARNESS (MAIN)
SENSOR LOCKOUT
HARNESS (MAIN)
OVERHEAT
PCB
CH SENSOR FAULTY
PCB
MAINS FUSE
FUSE GONE PCB
MAINS FUSEF2
FUSE GONE PCB
FURTHER INVESTIGATION F1
Z DIRECTION CHOICE OR CONTINUE
F1
HARNESS (MAIN)
FAN F1
HARNESS (MAIN)
F2 FAN
HARNESS (MAIN)
SOLENIOD
HARNESS (MAIN)
PUMP F3
HARNESS (MAIN)
GAS VALVE SOLENIOD MAIN
HARNESS (MAIN)
GV SOLENIOD MAIN
HARNESS (MAIN)
F2 F3 FURTHER INVESTIGATION
HARNESS (MAIN)
FURTHER INVESTIGATION LED PCB FAULT TO FAN RUNS BURNER IGNITES AND ESTABLISHES
Z DIRECTION CHOICE OR CONTINUE
NO RESET
PCB
PREHEAT
NORMAL OPERATION
F37 FAULT CODE
PCB
F37 FAULT CODE
HARNESS (MAIN)
CH NO DMAND
PCB
CH NO DEMAND2
PCB
PUMP RUNS
FILTER - DHW
POOR FLOW RATE
SWITCH - FLOW
OVERHEATOVERHEAT
PCB
FLUE OVERHEATOVERHEAT
HARNESS (MAIN)
UNABLE TO SET PRESSURE
GAS VALVE - SIEMENS
DHW COOL 2
BURNER PRESSURE ADJUSTMENT
DHW NOISY
BURNER PRESSURE ADJUSTMENT
FLAME BAFFLING
FLUE
BOCKED OR DAMAGED SPARKING OCCURS BURNER DOESNOT IGNITE
INJECTOR 1.30 - MAIN
FURTHER IN VESTIGATION F2
Z DIRECTION CHOICE OR CONTINUE
BOILER CUTS OUT ON FAULT CODE BEFORE REACHING 82 DEGREES
CHARACTERISTIC TEST FROM OPERATION OF SAFETY STATS AND HARNESS AT TEMP
FLOW SWITCH ASSEMBLY CLEAR
CHARACTERISTIC TEST FROM FLOW SWITCH ASSEMBLY
BOILER TEMPERATURE EXCEEDS 92 DEGREES AND BOILER STILL FIRING
CHARACTERISTIC TEST FROM OPERATION OF SAFETY STATS AND HARNESS AT TEMP
BOILER TEMP RISING RAPIDLY
CHARACTERISTIC TEST FROM OPERATION OF SAFETY STATS AND HARNESS AT TEMP
MAINS VOLTAGE ABSENT ON TEST 1
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
MAINS VOLTAGE PRESENT ON TEST 2
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
MAINS VOLTAGE ABSENT ON TEST 1
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
MAINS VOLTAGE PRESENT ON TEST 2
CHARACTERISTIC TEST FROM VOLTAGE FAN (AT PCB)
FAN RUNS SPARKING DOES NOT OCCUR
CHARACTERISTIC TEST FROM FAN RUNS BURNER IGNITES AND ESTABLISHES DHW DEMAND
FAN RUNS SPARKING OCCURS BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM FAN RUNS BURNER IGNITES AND ESTABLISHES DHW DEMAND
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM FAN RUNS BURNER IGNITES AND ESTABLISHES DHW DEMAND
BURNER IGNITES BUT BAFFLES OUT OR LIFTS OFF
CHARACTERISTIC TEST FROM FAN RUNS BURNER IGNITES AND ESTABLISHES DHW DEMAND
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW COOL / TEMP RISE POOR
CHARACTERISTIC TEST FROM OPERATION DHW
DHW COOL RADS HOT WITH NO CH DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
DHW NOISY KETTLING
CHARACTERISTIC TEST FROM OPERATION DHW
DHW RUNS HOT THEN COLD
CHARACTERISTIC TEST FROM OPERATION DHW
BOILER NOISY
CHARACTERISTIC TEST FROM OPERATION CH
BOILER UP TO TEMP RADS COLD
CHARACTERISTIC TEST FROM OPERATION CH
BOILER TEMP LOW SYSTEM TEMP LOW
CHARACTERISTIC TEST FROM OPERATION CH
OPERATION SATISFACTORY BUT BOILER GOES TO OVER HEAT
CHARACTERISTIC TEST FROM OPERATION CH
OPERATION SATISFACTORY BOILER AND SYSTEM REACHES TEMP BUT GETS TOO COOL BEFORE REFIRING
CHARACTERISTIC TEST FROM OPERATION CH
SYSTEM PRESSURE RISE EXCESSIVE
CHARACTERISTIC TEST FROM OPERATION CH
TEMP DIFF CORRECT LOCAL BOILING
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL FLOW RETURN (P=DIF NOK NOISY NSD)
DIFFERENTIAL OK
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL FLOW RETURN (P=DIF NOK NOISY NSD)
FUSE 1 (3AMP FUSED SPUR)
CHARACTERISTIC TEST FROM FURTHER INVESTIGATION FUSE
FURTHER INVESTIGATION F2 OR F3 ON PCB
CHARACTERISTIC TEST FROM FURTHER INVESTIGATION FUSE
INLET FILTER BLOCKED OR RESTRICTED
CHARACTERISTIC TEST FROM FLOW SWITCH ASSEMBLY
11/07/2018 13:48:57 1807_1_50_1 20/07/2018 14:02:50
11/07/2018 14:51:09
VOLTAGE MODUREG
DHW THERMOSTAT TO MAX
RUN DHW TAP ON MAXIMUM FLOW RATE
VOLTAGE MODUREG FROM PCB
{GAINPCBACS}
DHW THERMOSTAT TO MAX
RUN DHW TAP ON MAXIMUM FLOW RATE
VOLTAGE FAN (AT PCB)
GAIN ACCESS TO CONTROL BOX AND CONNECTOR X7
LINK INTEGRAL CLOCK CONNECTIONS
REMOVE WHITE WIRES F
RESISTANCE TIMER HARNESS
REMOVE CONNECTOR X2 FROM PCB AND THE
CONNECTIONS 3 & 5 (WHITE WIRES) FROM INTEGRAL TIMER
LINK INTEGRAL CLOCK CONNECTIONS
REMOVE WHITE WIRES F
RESISTANCE TIMER HARNESS
REMOVE CONNECTOR X2 FROM PCB AND THE
CONNECTIONS 3 & 5 (WHITE WIRES) FROM INTEGRAL TIMER
VOLTAGE FAN (AT PCB)
GAIN ACCESS TO CONTROL BOX AND CONNECTOR X7
VOLTAGE FROM PRESSURE SWITCH DURING OPERATION
{GAINPCBACS}
CONNECTOR X4 IS LOCATED ON LEFT HAND SIDE OF PCB
RESISTANCE SENSOR DHW
REMOVE BLUE LEADS FROM DHW SENSOR
INSPECTION TUBES AIR PRESSURE
REMOVE SILICONE RUBBER TUBES FROM THE VENTURI
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
RESISTANCE SENSOR TEMP DHW
REMOVE BLUE LEADS FROM DHW SENSOR
RESISTANCE SENSOR FLUE OVERHEAT STAT
DISCONNECT THE GREY LEADS FROM THE FLUE OVERHEAT THERMOSTAT
INSPECTION TUBES AIR PRESSURE
REMOVE SILICONE RUBBER TUBES FROM THE VENTURI
INSPECTION TUBES AIR PRESSURE
REMOVE SILICONE RUBBER TUBES FROM THE VENTURI
PRESSURE GAS INLET
UNDO INLET PRESSURE TEST POINT
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
PRESSURE GAS INLET
UNDO INLET PRESSURE TEST POINT
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
AIR PRESSURE SWITCH PROVING AT APS AIR FLOW TEST
SET PERFORMANCE TEST
INSPECTION TUBES AIR PRESSURE
REMOVE SILICONE RUBBER TUBES FROM THE VENTURI
CAN HIGH LOW BURNER PRESSURE BE ADJUSTED
DHW TEMPERATURE CONT
CAN HIGH LOW BURNER PRESSURE BE ADJUSTED
DHW TEMPERATURE CONT
VOLTAGE PUMP AT (PCB)
{GAINPCBACS}
PREHEAT OFF (ECO SHOWING IN DISPLAY)
PRESSURE GAS BURNER
DHW THERMOSTAT TURNE
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
REMOVE WIRE EXTERNAL CONTROLS DOES BOILER STILL FIRE
REMOVE ONE OR BOTH WIRES FROM EXTERNAL CONTROLS CONNECTION
CAN BOILER BE RESET
ALLOW BOILER TO COOL
RESISTANCE SAFETY STATS AND HARNESS
{GAINPCBACS}
DISCONNECT CONNECTOR FROM X4 ON THE PCB
RESISTANCE SAFETY THERMOSTAT
DISCONNECT THE GREY LEADS FROM THE OVERHEAT STAT
RESISTANCE SENSOR TEMP DHW AND HARNESS
DISCONNECT CONNECTOR X2 ON THE PCB
RESISTANCE SENSOR DHW
REMOVE BLUE LEADS FROM DHW SENSOR
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
DISCONNECT X4 PLUG ON THE PCB
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
RESISTANCE GAS VALVE SOLENOID MAIN
REMOVE THE LEADS FROM THE GAS VALVE
VOLTAGE MAINS POWER INPUT TO APPLIANCE
GAIN ACCESS TO CONNECTOR X1 ON PCB
RESISTANCE GAS VALVE SOLENOID MODULATING
REMOVE THE LEADS FROM THE GAS VALVE
RESISTANCE GAS VALVE SOLENOID MAIN
REMOVE THE LEADS FROM THE GAS VALVE
RESISTANCE FUSE F1 (FUSED SPUR)
REMOVE FUSE FROM FUSED SPUR
RESISTANCE GAS VALVE SOLENOID MODULATING
REMOVE THE LEADS FROM THE GAS VALVE
IS DHW FLOW SWITCH OPEN CIRCUIT
DHW TAP OFF
DISCONNECT THE X2 CONNECTOR FROM THE PCB
DOES BURNER EXTINGUISH AFTER DEMAND
PREHEAT OFF (ECO IN DISPLAY)
IS BOILER IN PREHEAT
NO DEMAND
RESISTANCE LOW WATER PRESSURE SWITCH
DISCONNECT THE BLACK LEADS FROM THE PRIMARY CIRCUIT SWITCH
RESISTANCE SAFETY STATS AND HARNESS
{GAINPCBACS}
DISCONNECT CONNECTOR FROM X4 ON THE PCB
RESISTANCE SAFETY THERMOSTAT
DISCONNECT THE GREY LEADS FROM THE OVERHEAT STAT
CAN HIGH LOW BURNER PRESSURE BE ADJUSTED
DHW TEMPERATURE CONT
RESISTANCE FUSE ( APPLIANCE F1)
REMOVE FUSE FROM PCB
RESISTANCE FLOW SWITCH
DISCONNECT THE TWO PINK LEADS ON THE DHW FLOW SWITCH.
FLOW SWITCH ASSEMBLY
DHW DISCHARGED AND DRAINED
REMOVE THE DHW FLOW SWITCH GROUP ASSEMBLY
PRESSURE GAS INLET
UNDO INLET PRESSURE TEST POINT
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
CAN HIGH LOW BURNER PRESSURE BE ADJUSTED
DHW TEMPERATURE CONT
INSPECTION GAS VALVE SHUT DOWN
CH DEMAND OFF
PREHEAT SWITCHED OFF (ECO IN DISPLAY)
RESISTANCE FLUE OVERHEAT
DISCONNECT BOTH OF THE GREY LEADS FROM THE FLUE OVERHEAT STAT
RESISTANCE SAFETY THERMOSTAT
DISCONNECT THE GREY LEADS FROM THE OVERHEAT STAT
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION COMBUSTION CHAMBER
REMOVE FRONT COVER
REMOVE INNER COMBUSTION COVER
IS DHW FLOW SWITCH OPEN CIRCUIT
DHW TAP OFF
DISCONNECT THE X2 CONNECTOR FROM THE PCB
IS DHW FLOW SWITCH OPEN CIRCUIT
DHW TAP OFF
DISCONNECT THE X2 CONNECTOR FROM THE PCB
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
RESISTANCE SENSOR DHW
REMOVE BLUE LEADS FROM DHW SENSOR
LINK EXTERNAL CONTROLS
REMOVE ROOM STAT WIR
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
OBSERVATION DISCONNECT GAS VALVE - DISPLAY ILLUMINATES?
REMOVE CONNECTOR FROM GAS VALVE AND MAKE SAFE
RESISTANCE FLOW SWITCH
DISCONNECT THE TWO PINK LEADS ON THE DHW FLOW SWITCH.
RESISTANCE LOW WATER PRESSURE SWITCH
DISCONNECT THE BLACK LEADS FROM THE PRIMARY CIRCUIT SWITCH
RESISTANCE SENSOR TEMP PRIMARY AND HARNESS
DISCONNECT X4 PLUG ON THE PCB
RESISTANCE SENSOR TEMP DHW AND HARNESS
DISCONNECT CONNECTOR X2 ON THE PCB
RESISTANCE SENSOR OVERHEATS AND HARNESS
{GAINPCBACS}
DISCONNECT CONNECTOR FROM X4 ON THE PCB
RESISTANCE SENSOR OVERHEAT STAT
DISCONNECT THE GREY LEADS FROM THE OVERHEAT STAT
AIR PRESSURE SWITCH PROVING AT APS AIR FLOW TEST
SET PERFORMANCE TEST
AIR PRESSURE SWITCH HARNESS CONTINUITY
REMOVE LEADS FROM AIR PRESSURE SWITCH AND REMOVE CONNECTION X4 FROM PCB
VOLTAGE SUPPLY FROM PCB TO APS
GAIN ACCESS TO CONNECTOR X4 ON PCB
INSPECTION VENTURI
REMOVE SILICONE RUBBER TUBES FROM THE VENTURI
INSPECTION CONDENSING HEAT EXCHANGER FLUEWAYS
REMOVE COMBUSTION COVER AND FAN ASSEMBLY
PUMP RUNS CENTRAL HEATING DEMAND
PREHEAT OFF (ECO SHOWING IN DISPLAY)
CH THERMOSTAT TURNED TO MID POSITION
RESISTANCE FLOW SWITCH
DISCONNECT THE TWO PINK LEADS ON THE DHW FLOW SWITCH.
AIR PRESSURE SWITCH PROVING AT PCB
GAIN ACCESS TO PCB (
PRESSURE GAS BURNER IGNITION
UNDO BURNER PRESSURE TEST POINT
ATTACH PRESSURE GAUGE TO THE BURNER PRESSURE TEST POINT
PRESSURE GAS BURNER IGNITION
UNDO BURNER PRESSURE TEST POINT
ATTACH PRESSURE GAUGE TO THE BURNER PRESSURE TEST POINT
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION FAN MECHANICAL
REMOVE FAN
INSPECTION BURNER
REMOVE THE BURNER
VOLTAGE GAS VALVE (AT PCB)
{GAINPCBACS}
REMOVE CONNECTOR FROM GAS VALVE AND MAKE SAFE
RESISTANCE GAS VALVE HARNESS
REMOVE X7 CONNECTOR FROM PCB AND PLUG FROM GAS VALVE
SPARKING OCCUR AT PCB
REMOVE SPARK LEAD FR
AIR PRESSURE SWITCH HARNESS CONTINUITY
REMOVE LEADS FROM AIR PRESSURE SWITCH AND REMOVE CONNECTION X4 FROM PCB
INSPECTION VENTURI
REMOVE SILICONE RUBBER TUBES FROM THE VENTURI
INSPECTION FAN
REMOVE FAN
VOLTAGE SUPPLY FROM PCB TO APS
GAIN ACCESS TO CONNECTOR X4 ON PCB
RESISTANCE IGNITION LEAD
REMOVE FLAME DETECTION ELECTRODE FROM ITS HOUSING
RESISTANCE SENSOR DHW
REMOVE BLUE LEADS FROM DHW SENSOR
BURNER PRESSURE
THERMOSTAT TURNED TO MAX
CONNECT A U-GAUGE TO THE BURNER GAS PRESSURE TEST POINT
IS HIGH LOW BURNER PRESSURE CORRECT
DHW TEMPERATURE CONT
RESISTANCE SENSOR DHW
REMOVE BLUE LEADS FROM DHW SENSOR
IS HIGH LOW BURNER PRESSURE CORRECT
DHW TEMPERATURE CONT
BURNER PRESSURE
THERMOSTAT TURNED TO MAX
CONNECT A U-GAUGE TO THE BURNER GAS PRESSURE TEST POINT
INSPECTION CONDENSING HEAT EXCHANGER FLUEWAYS
REMOVE COMBUSTION COVER AND FAN ASSEMBLY
RESISTANCE SENSOR DHW
REMOVE BLUE LEADS FROM DHW SENSOR
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
INSPECTION BURNER
REMOVE THE BURNER
INSPECTION HEAT EXCHANGER CONDENSING (FLUE WAYS)
REMOVE COMBUSTION COVER AND FAN ASSEMBLY
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
DOES BURNER PRESSURE STAY ON MAX
THERMOSTAT TURNED TO
VOLTAGE PUMP AT (PUMP)
REMOVE THE COVER FROM THE PUMP
APPLY DEMAND
INSPECTION TUBES AIR PRESSURE
REMOVE SILICONE RUBBER TUBES FROM THE VENTURI
INSPECTION VENTURI
REMOVE SILICONE RUBBER TUBES FROM THE VENTURI
INSPECTION FAN
REMOVE FAN
INSPECTION CONDENSING HEAT EXCHANGER FLUEWAYS
REMOVE COMBUSTION COVER AND FAN ASSEMBLY
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO THE INLET PRESSURE TEST POINT
EXPANSION VESSEL PRESSURE
BOILER DISCHARGED
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
TEMPERATURE DIFFERENTIAL FLOW RETURN (CH)
PLACE TELEGAN CLAMPS ON THE FLOW AND RETURN PIPES CLOSE TO THE COMBUSTION CHAMBER
IS DHW FLOW SWITCH OPEN CIRCUIT
DHW TAP OFF
DISCONNECT THE X2 CONNECTOR FROM THE PCB
REMOVE WIRE INTEGRAL TIMER DOES BOILER STILL FIRE
REMOVE THE TWO WHITE WIRES ON TERMINALS 3 AND 4 OF THE INTEGRAL TIMER AND MAKE SAFE
RESISTANCE FLUE OVERHEAT
DISCONNECT BOTH OF THE GREY LEADS FROM THE FLUE OVERHEAT STAT
RESISTANCE GAS VALVE SOLENOID MAIN AND HARNESS
{GAINPCBACS}
DISCONNECT PLUG MARKED X7 FROM THE PCB
RESISTANCE GAS VALVE SOLENOID MODULATING AND HARNESS
REMOVE CONNECTION X2 FROM THE PCB
RESISTANCE PUMP AND HARNESS
{GAINPCBACS}
DISCONNECT PLUG MARKED X3 FROM PCB
RESISTANCE GAS VALVE SOLENOID MAIN AND HARNESS
{GAINPCBACS}
DISCONNECT PLUG MARKED X7 FROM THE PCB
RESISTANCE GAS VALVE SOLENOID MODULATING AND HARNESS
REMOVE CONNECTION X2 FROM THE PCB
RESISTANCE PUMP AND HARNESS
{GAINPCBACS}
DISCONNECT PLUG MARKED X3 FROM PCB
RESISTANCE FAN AND HARNESS
DISCONNECT PLUG MARKED X7 FROM THE PCB
RESISTANCE FAN AND HARNESS
DISCONNECT PLUG MARKED X7 FROM THE PCB
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
{GAINPCBACS}
REMOVE CONNECTOR X2 FROM PCB
TEMPERATURE SYSTEM FLOW
ATTACH TEMP CLAMPS T
RESISTANCE SENSOR PRIMARY
REMOVE RED LEADS FROM CH SENSOR
CAN BOILER BE RESET
ALLOW BOILER TO COOL
RESISTANCE FLUE OVERHEAT
DISCONNECT BOTH OF THE GREY LEADS FROM THE FLUE OVERHEAT STAT
INSPECTION COMBUSTION CHAMBER
REMOVE FRONT COVER
REMOVE INNER COMBUSTION COVER
RESISTANCE FUSE ( APPLIANCE F2)
REMOVE FUSE FROM PCB
RESISTANCE ELECTRODE LEAD
REMOVE FLAME DETECTION ELECTRODE FROM ITS HOUSING
RESISTANCE ELECTRODE LEAD
REMOVE FLAME DETECTION ELECTRODE FROM ITS HOUSING
System Information
- Total Tests: 452
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control