Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
DHW Demand
Gain access to control box and connector X7
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Test 1: Measure the AC voltage between pin 1 on connector X7 and the incoming earth.
Expect mains voltage (which should remain constant approximately 25 seconds after power on)
If no mains voltage is present there is no need to continue to test 2 choose outcome "mains voltage absent on test 1" below.
Test 2: Measure the AC voltage between pin 2 on connector X7 and the incoming earth.
Expect approximately 0v.
Expect mains voltage (which should remain constant approximately 25 seconds after power on)
If no mains voltage is present there is no need to continue to test 2 choose outcome "mains voltage absent on test 1" below.
Test 2: Measure the AC voltage between pin 2 on connector X7 and the incoming earth.
Expect approximately 0v.