ELM LE-BLANC GVM C23
WARNING - IMPORTA
EXCESSIVE SYSTEM PRESSURE
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
CENTRAL HEATING
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
HOT WATER
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
CH MODULATION
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
CH BURNER HIGH FLAME
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
CH HIGH FAN
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
CH FLOW VALVE OPERATION
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASING SWITCH
DHW MODULATION
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
DHW BURNER HIGH FLAME
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
DHW BURNER LOW FLAME
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
DHW HIGH FAN
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
DHW DEMAND
{ISOLATEMAINSPOWER}
PILOT OUT GAS CHECK
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
PILOT OUT
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
PILOT ESTABLISHED
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
PILOT IGNITES
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
PILOT SPARKING
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
PILOT HIGH FAN
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
PILOT SLOW FAN
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
SYSTEM CHECKS
{ISOLATEMAINSPOWER}
ELM LE-BLANC GVM C23
G.C. NUMBER 47 241 0
DHW MODULATION
MODULATING BOX
CH FLOW VALVE OPERATION
ROTARY SWITCH
CH FLOW VALVE OPERATION
CLOCK/LINK
CH FLOW VALVE OPERATION
WATER VALVE SWITCHES
CH HIGH FAN
OPERATIVE CH THERMOSTAT
CH BURNER HIGH FLAME
DIFFERENTIAL FLOW VALVE MICROSWITCH
CH MODULATION
OPERATIVE CH THERMOSTAT
EXCESSIVE SYSTEM PRESSURE
EXPANSION VESSEL
HOT WATER
SCALED PRIMARY HEAT EXCHANGER
PILOT SLOW FAN
BOILER CASE SWITCH
DHW DEMAND
SCALED PRIMARY HEAT EXCHANGER
ELECTRICAL CHECKS
ELECTRICAL CHECKS
SYSTEM CHECKS
SYSTEM CHECKS
PILOT SLOW FAN
240V MAINS SUPPLY
PILOT SLOW FAN
FUSE 3A
PILOT SLOW FAN
PRINTED CIRCUIT BOARD
PILOT HIGH FAN
IGNITION SWITCH
PILOT SPARKING
CONDENSATE TRAP
PILOT SPARKING
FLUE
PILOT SPARKING
AIR PRESSURE MICROSWITCH
PILOT SPARKING
TRANSFORMER
PILOT IGNITES
GAS CONTROL VALVE KNOB
PILOT IGNITES
PILOT INJECTOR
PILOT ESTABISHED
THERMOCOUPLE
PILOT ESTABLISHED
PILOT OFF PUSH BUTTON
PILOT OUT
PILOT OFF PUSH BUTTON
PILOT OUT GAS CHECK
GAS VALVE ASSEMBLY
DHW DEMAND
WATER VALVE DIAPHRAGM
DHW DEMAND
WATER VALVE PISTON
DHW HIGH FAN
WATER VALVE SWITCHES
DHW BURNER LOW FLAME
FUSE 0.25A
DHW BURNER LOW FLAME
IGNITION SWITCH
DHW BURNER LOW FLAME
TRANSFORMER
DHW BURNER LOW FLAME
CH LIMIT THERMOSTAT
DHW BURNER LOW FLAME
SOLENOIDS
DHW BURNER HIGH FLAME
SOLENOIDS
DHW MODULATION
GAS VALVE ASSEMBLY
CH FLOW VALVE OPERATION
ROOM THERMOSTAT/LINK
CH FLOW VALVE OPERATION
DIFFERENTIAL FLOW VALVE
CENTRAL HEATING
NON-RETURN VALVE
CENTRAL HEATING
SCALED PRIMARY HEAT EXCHANGER
PILOT SLOW FAN
ROTARY SWITCH
PILOT SLOW FAN
FAN
PILOT HIGH FAN
FAN
PILOT SPARKING
IGNITION SWITCH
PILOT SPARKING
AIR PRESSURE SWITCH PADDLE AND LINKAGE
PILOT SPARKING
SPARK ELECTRODE AND LEAD
PILOT SPARKING
SPARK GENERATOR
PILOT IGNITES
GAS VALVE ASSEMBLY
PILOT ESTABISHED
OVERHEAT THERMOSTAT
PILOT ESTABISHED
GAS VALVE ASSEMBLY
PILOT ESTABISHED
CH FLOW LIMIT THERMOSTAT
DHW DEMAND
WATER VALVE SPINDLE
DHW BURNER LOW FLAME
WATER VALVE SWITCHES
DHW BURNER LOW FLAME
PRINTED CIRCUIT BOARD
DHW BURNER LOW FLAME
DHW LIMIT THERMOSTAT
DHW BURNER LOW FLAME
BURNER INJECTORS
DHW BURNER LOW FLAME
GAS VALVE ASSEMBLY
BOILER CYCLES A LOT OR OVERHEATS, COLD RADIATORS
CHARACTERISTIC TEST FROM CENTRAL HEATING
CH NOISY OPERATION, WARM OR COLD RADIATORS
CHARACTERISTIC TEST FROM CENTRAL HEATING
CH QUIET OPERATION, WARM OR COLD RADIATORS
CHARACTERISTIC TEST FROM CENTRAL HEATING
21/08/2014 10:13:39 1408_1_50_1 27/08/2014 14:55:09
27/08/2014 09:41:27
MODULATING BOX OPERATION
{ISOLATEMAINSPOWER}
ROOM THERMOSTAT VOLTAGE
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
ROTARY SWITCH CH VOLTAGE
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
PUMP VOLTAGE
ROTARY SWITCH TO DHW
ROTARY SWITCH CH VOLTAGE
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
MAINS VOLTAGE
ROTARY SWITCH IN OFF POSITION
IGNITION SWITCH A
{ISOLATEMAINSPOWER}
REMOVE FRONT PANEL OF ELECTRICAL CONTROL BOX
SPARK APS VOLTAGE
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
AIR PRESSURE SWITCH OPERATION
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
CONDENSATE TRAP
{ISOLATEMAINSPOWER}
TRANSFORMER PRIMARY
{ISOLATEMAINSPOWER}
REMOVE FRONT PANEL OF ELECTRICAL CONTROL BOX
GAS CONTROL VALVE KNOB
{ISOLATEMAINSPOWER}
OVERHEAT THERMOSTAT VOLTAGE
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
THERMOCOUPLE VOLTAGE
{ISOLATEMAINSPOWER}
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
PILOT OFF BUTTON VOLTAGE
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASING SWITCH
DHW MINIMUM FLOW RATE
{ISOLATEMAINSPOWER}
WATER VALVE MICROSWITCH 2 NO VOLTAGE
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
0.25A FUSE
{ISOLATEMAINSPOWER}
IGNITION SWITCH B: NC
{ISOLATEMAINSPOWER}
REMOVE FRONT PANEL OF ELECTRICAL CONTROL BOX
CH LIMIT THERMOSTAT
{ISOLATEMAINSPOWER}
SOLENOID 1 RESISTANCE
{ISOLATEMAINSPOWER}
PUMP RUNNING
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
TIMER / LINK VOLTAGE
ROTARY SWITCH TO CH/DHW POSITION
CH THERMOSTAT TO MAXIMUM
HOLD IN BOILER CASE SWITCH
SLOW FAN VOLTAGE
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
3A FUSE
{ISOLATEMAINSPOWER}
BOILER CASING SWITCH
{ISOLATEMAINSPOWER}
REMOVE FRONT PANEL OF ELECTRICAL CONTROL BOX
AIR DETECT VOLTAGE
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
SPARK LEAD
{ISOLATEMAINSPOWER}
REMOVE SPARK ELECTRODE LEAD FROM ELECTRICAL CONTROL BOX CONNECTOR
PILOT INJECTOR
{ISOLATEMAINSPOWER}
CH FLOW LIMIT THERMOSTAT VOLTAGE
ROTARY SWITCH TO DHW POSITION
HOLD IN BOILER CASE SWITCH
WATER VALVE DIAPHRAGM
{ISOLATEMAINSPOWER}
WATER VALVE PISTON
{ISOLATEMAINSPOWER}
SOLENOID VOLTAGE
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
DC POWER SUPPLY
ROTARY SWITCH TO DHW POSITION
DHW TEMPERATURE CONTROL TO MAXIMUM
HOLD IN BOILER CASE SWITCH
TRANSFORMER SECONDARY
{ISOLATEMAINSPOWER}
REMOVE FRONT PANEL OF ELECTRICAL CONTROL BOX
DHW BURNER PRESSURE
ROTARY SWITCH TO DHW