Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove front panel of Electrical Control Box
Remove front panel of Electrical Control Box
Measurement:
Measure resistance across White wires of Transformer secondary winding.
Resistance should be in the range 5 -10 ohms.
Note:
The secondary resistance reading assumes a resistance of 3 ohms for the fused test probes.
Resistance should be in the range 5 -10 ohms.
Note:
The secondary resistance reading assumes a resistance of 3 ohms for the fused test probes.

Isolate as per TOPs P4
and refit as necessary