Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove front panel of Electrical Control Box
Remove front panel of Electrical Control Box
Measurement:
Measure resistance across Red wires of Transformer primary winding.
Resistance should be in the range 110-140 ohms on the main PCB.
Resistance should be in the range 110-140 ohms on the main PCB.

Isolate as per TOPs P4
and refit as necessary