POTTERTON MIDAS SFI
G.C. NUMBER 47 494 0
CH PUMP OVERRUN
PURGE SWITCH IN NORM
CH ANTI-CYCLING PERIOD
PURGE SWITCH IN NORM
HW LOW FAN OVERRUN
PURGE SWITCH IN NORM
HW PUMP OVERRUN
PURGE SWITCH IN NORM
CH BURNER MODULATION
{ISOLATEMAINSPOWER}<
HOT WATER
PURGE SWITCH IN NORM
CH PRESSURE RISE
PURGE SWITCH IN NORM
CENTRAL HEATING
{ISOLATEMAINSPOWER}<
HW BURNER MODULATES
{ISOLATEMAINSPOWER}<
HW TOP UP OPERATION
PURGE SWITCH IN NORM
HW HIGH BURNER
{ISOLATEMAINSPOWER}<
HW PILOT IGNITES
PURGE SWITCH IN NORM
HW HIGH FAN
PURGE SWITCH IN NORM
HW PUMP RUNS
PURGE SWITCH IN NORM
CH LOW BURNER
{ISOLATEMAINSPOWER}<
CH PILOT IGNITES
PURGE SWITCH IN NORM
CH SPARKING
PURGE SWITCH IN NORM
CH LOW FAN
PURGE SWITCH IN NORM
CH TIMED PUMP RUNS
PURGE SWITCH IN NORM
CH CONTINUOUS PUMP RUNS
PURGE SWITCH IN NORM
HW FLOW RATE
{ISOLATEMAINSPOWER}
POTTERTON MIDAS SFI
{ISOLATEMAINSPOWER}<
CH LOW BURNER
MAIN SOLENOID
CH LOW BURNER
GAS VALVE
HW PUMP RUNS
HW SELECTOR SWITCH
HW HIGH FAN
HW INLET SENSOR
HW PILOT IGNITES
AIR FLOW SENSOR
HW PILOT IGNITES
AIR FLOW PIPE
HW PILOT IGNITES
FLUE ASSEMBLY
HW PILOT IGNITES
CH SENSOR
HW PILOT IGNITES
HW FLOW SENSOR
HW PILOT IGNITES
HW POTENTIOMETER
HW TOP UP OPERATION
HW FLOW SENSOR
HW TOP UP OPERATION
HW POTENTIOMETER
HW BURNER MODULATES
HW FLOW SENSOR
HW BURNER MODULATES
HW INLET SENSOR
HW BURNER MODULATES
HW POTENTIOMETER
HW BURNER MODULATES
MAIN PCB
CENTRAL HEATING
CH NON RETURN VALVE
CH PRESSURE RISE
EXPANSION VESSEL
HOT WATER
SECONDARY HEAT EXCHANGER
CH BURNER MODULATION
CH SENSOR
CH BURNER MODULATION
CH POTENTIOMETER
HW HIGH BURNER
MAIN PCB
HW HIGH BURNER
MODUREG SOLENOID
HIGH FLOW
AIR FLOW SENSOR
CH PUMP OVERRUN
MAIN PCB
CH ANTI-CYCLING PERIOD
MAIN PCB
HW LOW FAN OVERRUN
MAIN PCB
HW PUMP OVERRUN
MAIN PCB
ELECTRICAL SAFETY CHECKS
ELECTRIC CHECKS
SYSTEM CHECKS
SYSTEM CHECKS
HW FLOW RATE
HW FILTER
HW FLOW RATE
HW RESTRICTOR
CH CONTINUOUS PUMP RUNS
WATER PRESSURE GAUGE
CH CONTINUOUS PUMP RUNS
OVERHEAT THERMOSTAT
CH CONTINUOUS PUMP RUNS
CH SELECTOR SWITCH
CH CONTINUOUS PUMP RUNS
ROOM THERMOSTAT
CH CONTINUOUS PUMP RUNS
TRANSFORMER
CH TIMED PUMP RUNS
TIMER
CH LOW FAN
PURGE SWITCH
CH LOW FAN
CH POTENTIOMETER
CH LOW FAN
CH SENSOR
IGNITION PCB CIRCUIT 1 VOLTAGE (CH DEMAND)
IGNITION PCB
CH LOW FAN VOLTAGE
MAIN PCB
CH SPARKING
AIR FLOW SENSOR
CH SPARKING
AIR FLOW PIPE
CH SPARKING
FLUE ASSEMBLY
CH SPARKING
IGNITION PCB
CH PILOT IGNITES
IGNITION PCB
CH PILOT IGNITES
PILOT ASSEMBLY
CH LOW BURNER
SPARK ELECTRODE AND LEAD
CH LOW BURNER
BURNER INJECTOR
HW PUMP RUNS
HW PUMP
HW PUMP RUNS
MAIN PCB
HW HIGH FAN
FAN ASSEMBLY
HW HIGH FAN
MAIN PCB
HW PILOT IGNITES
MAIN PCB
HW TOP UP OPERATION
HW NON RETURN VALVE
HW TOP UP OPERATION
SECONDARY HEAT EXCHANGER
HW TOP UP OPERATION
PRIMARY HEAT EXCHANGER
HW TOP UP OPERATION
CH NON RETURN VALVE
HW TOP UP OPERATION
MAIN PCB
HW BURNER MODULATES
GAS VALVE
CENTRAL HEATING
HW NON RETURN VALVE
CH BURNER MODULATION
MAIN PCB
HW HIGH BURNER
GAS VALVE
HW HIGH BURNER
MODUREG
BLOCKED ON HIGH FLOW
AIR FLOW SENSOR
BLOCKED AIR FLOW
PRIMARY HEAT EXCHANGER
BLOCKAGE IN AIR FLOW
FLUE ASSEMBLY
HW FLOW RATE
SECONDARY HEAT EXCHANGER
CH CONTINUOUS PUMP RUNS
WATER PRESSURE SWITCH
WATER PRESSURE SWITCH RESISTANCE
MAIN PCB
CH CONTINUOUS PUMP RUNS
CH PUMP
CH PUMP VOLTAGE
MAIN PCB
CH TIMED PUMP RUNS
CH SELECTOR SWITCH
PURGE SWITCH RESISTANCE
MAIN PCB
MAIN PCB CIRUIT 1 VOLTAGE (CH DEMAND)
IGNITION PCB
CH LOW FAN
FAN ASSEMBLY
CH SPARKING
MAIN PCB
CH SPARKING
SPARK ELECTRODE AND LEAD
CH PILOT IGNITES
GAS VALVE
CH LOW BURNER
MODUREG
CH LOW BURNER
IGNITION PCB
BOILER NOISY, CUTS OUT QUICKLY, FLOW COLD
CHARACTERISTIC TEST FROM HW TOP UP OPERATION
BOILER NOISY, FLOW WARM, RETURN COLD
CHARACTERISTIC TEST FROM HW TOP UP OPERATION
BOILER NOISY, BOTH PIPES WARM
CHARACTERISTIC TEST FROM HW TOP UP OPERATION
TOP UP OPERATION TOO LONG
CHARACTERISTIC TEST FROM HW TOP UP OPERATION
NO TOP UP OPERATION
CHARACTERISTIC TEST FROM HW TOP UP OPERATION
BOILER NOISY, BURNER OFF QUICKLY
CHARACTERISTIC TEST FROM CENTRAL HEATING
CHANGE TO TOP UP OPERATION
CHARACTERISTIC TEST FROM CENTRAL HEATING
QUIET OPERATION, RADIATORS NOT HEATING
CHARACTERISTIC TEST FROM CENTRAL HEATING
BURNER LIGHTS, PRESSURE GREATER THAN MINIMUM
CHARACTERISTIC TEST FROM CH LOW BURNER
BURNER DOES NOT LIGHT
CHARACTERISTIC TEST FROM CH LOW BURNER
11/12/2012 13:24:39 1303_1_50_1 10/01/2013 13:32:08
11/12/2012 13:40:46
HW PUMP VOLTAGE
PURGE SWITCH IN NORM
HW SWITCH RESISTANCE
{ISOLATEMAINSPOWER}
HW SWITCH IN ON POSITION
HW HIGH FAN VOLTAGE
PURGE SWITCH IN NORM
HW INLET SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE BLUE WIRES FROM THE HW INLET SENSOR
AIR FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE MAIN PCB CONNECTOR MARKED PL3 FROM THE PCB
HW FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE RED WIRES FROM THE HW FLOW SENSOR
CH SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE GREY WIRES FROM THE CH FLOW SENSOR
DOES LED 2 LIGHT GO OUT
PURGE SWITCH IN NORM
IS AIR FLOW SENSOR BLOCKED?
{ISOLATEMAINSPOWER}<
MODUREG SOLENOID RESISTANCE
{ISOLATEMAINSPOWER}
IS MAIN HEAT EXCHANGER BLOCKED?
{ISOLATEMAINSPOWER}
GAIN ACCESS TO COMBUSTION CHAMBER BY REMOVING THE INNER COMBUSTION COVER.
HW FILTER
{ISOLATEMAINSPOWER}
WATER OFF
TRANSFORMER INPUT VOLTAGE
PURGE SWITCH IN NORMAL POSITION
HW SWITCH IN OFF POSITION
CH SWITCH IN OFF POSITION
TIMER RESISTANCE
{ISOLATEMAINSPOWER}
ENSURE TIMER IS IN AN ON PERIOD
WATER PRESSURE SWITCH RESISTANCE
{ISOLATEMAINSPOWER}
WATER PRESSURE
{ISOLATEMAINSPOWER}
CH SELECTOR SWITCH RESISTANCE (CH CONTINUOUS)
{ISOLATEMAINSPOWER}
CH SWITCH IN CH CONTINUOUS POSITION
IGNITION PCB SUPPLY VOLTAGE (CH DEMAND)
PURGE SWITCH IN NORM
PURGE SWITCH RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE TWO WHITE WIRES FROM THE PURGE SWITCH
IGNITION PCB CIRCUIT 1 VOLTAGE (CH DEMAND)
PURGE SWITCH IN NORM
CH IGNITION PCB VOLTAGE
PURGE SWITCH IN NORM
AIR FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE MAIN PCB CONNECTOR MARKED PL3 FROM THE PCB
CH PILOT VOLTAGE
PURGE SWITCH IN NORM
SPARK ELECTRODE & LEAD
{ISOLATEMAINSPOWER}
AIR FLOW AIR PIPE
{ISOLATEMAINSPOWER}
CH SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE GREY WIRES FROM THE CH FLOW SENSOR
HW FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE RED WIRES FROM THE HW FLOW SENSOR
HW POTENTIOMETER RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE MAIN PCB CONNECTOR PL5 FROM THE PCB
HW FLOW SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE RED WIRES FROM THE HW FLOW SENSOR
HW POTENTIOMETER RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE MAIN PCB CONNECTOR PL5 FROM THE PCB
HW INLET SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE BLUE WIRES FROM THE HW INLET SENSOR
HW POTENTIOMETER RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE MAIN PCB CONNECTOR PL5 FROM THE PCB
HW MODULATION VOLTAGE
PURGE SWITCH IN NORM
CH BYPASS HEAT UP
PURGE SWITCH IN NORM
CH POTENTIOMETER RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE MAIN PCB CONNECTOR MARKED PL5 FROM THE PCB
HW FULL MODULATION VOLTAGE
PURGE SWITCH IN NORM
MODUREG MECHANICAL OPERATION
PURGE SWITCH IN NORM
HW RESTRICTOR
{ISOLATEMAINSPOWER}
WATER OFF
CH PUMP VOLTAGE
PURGE SWITCH IN NORM
MAINS POWER SUPPLY
PURGE SWITCH IN NORMAL POSITION
HW SWITCH IN OFF POSITION
CH SWITCH IN OFF POSITION
OVERHEAT THERMOSTAT RESISTANCE
{ISOLATEMAINSPOWER}
ENSURE THAT THE BOILER IS NOT IN AN OVERHEAT CONDITION
ROOM THERMOSTAT RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE MAIN PCB CONNECTOR PL8 FROM THE PCB
TRANSFORMER OUTPUT VOLTAGE
PURGE SWITCH IN NORMAL POSITION
HW SWITCH IN OFF POSITION
CH SWITCH IN OFF POSITION
IGNITION PCB CIRCUIT 2 VOLTAGE (CH DEMAND)
PURGE SWITCH IN NORM
CH POTENTIOMETER RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE MAIN PCB CONNECTOR MARKED PL5 FROM THE PCB
CH SENSOR RESISTANCE
{ISOLATEMAINSPOWER}
DISCONNECT THE GREY WIRES FROM THE CH FLOW SENSOR
CH LOW FAN VOLTAGE
PURGE SWITCH IN NORM
MAIN PCB CIRCUIT 1 VOLTAGE (CH DEMAND)
PURGE SWITCH IN NORM
CH IGNITION PCB SPARKING TUBE
PURGE SWITCH IN NORM
AIR FLOW AIR PIPE
{ISOLATEMAINSPOWER}
PILOT INJECTOR
{ISOLATEMAINSPOWER}
CH GAS VALVE VOLTAGE
PURGE SWITCH IN NORM
GAS VALVE SOLENOID RESISTANCE
{ISOLATEMAINSPOWER}
BURNER GAS PRESSURE
{ISOLATEMAINSPOWER}<
System Information
- Total Tests: 180
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control