Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
WORCESTER 280 RSF.
G.C. NUMBER 47 311 1
HW TAP TURN OFF
OPERATING SWITCH IN WATER POSITION
HW BURNER MODULATION
OPERATING SWITCH IN
HW HIGH FLAME
OPERATING SWITCH IN
HW PILOT IGNITES
OPERATING SWITCH IN WATER POSITION
HW DEMAND INDICATOR
OPERATING SWITCH IN WATER POSITION
PUMP OVERRUN
OPERATING SWITCH IN WATER POSITION
TEMPERATURE CONTROL TO MAX
CH BURNER MODULATION
OPERATING SWITCH IN
CH HIGH FLAME
OPERATING SWITCH IN
CH LOW FLAME
OPERATING SWITCH IN HEATING & WATER POSITION
WATER PUMP RUNNING
OPERATING SWITCH IN
DIVERTER VALVE ARM CH
OPERATING SWITCH IN HEATING & WATER POSITION.
CH DEMAND INDICATOR
OPERATING SWITCH IN HEATING & WATER POSITION.
FROST THERMOSTAT STATE
{GAINPCBACS}
SYSTEM CHECKS
PLEASE ENSURE THAT THE FOLLOWING SYSTEM CHECKS ARE COMPLETED.
WORCESTER 280 RSF.
G.C. NUMBER 47 311 1
CH PILOT IGNITES
OPERATING SWITCH IN HEATING & WATER POSITION
CH LOW FLAME CORRECT PRESSURE
ATTACH U GAUGE TO BURNER PRESSURE TEST POINT
REMOVE THE ONE LEAD FROM THE MODULATING COIL
FUSE INVESTIGATION TREE
OUTSIDE MODEL
HW PILOT IGNITES
HOT WATER TEMPERATURE SENSOR (THERMISTOR)
HOT WATER TEMPERATURE SENSOR FIXING
HOT WATER TEMPERATURE SENSOR FIXING
HW TAP TURN OFF
WATER FLOW SWITCH (PROXIMITY SWITCH)
HOT WATER TEMPERATURE SENSOR (THERMISTOR)
HOT WATER TEMPERATURE SENSOR (THERMISTOR)
CH SENSOR
CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)
CENTRAL HEATING TEMPERATURE SENSOR FIXING
CENTRAL HEATING TEMPERATURE SENSOR FIXING
CH MODULATION
CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)
TEMPERATURE CONTROL POTENTIOMETER
TEMPERATURE CONTROL POTENTIOMETER
ELECTRICAL SAFETY CHECK
ELECTRICAL SAFETY CHECK
SYSTEM CHECKS
SYSTEM CHECKS
FROST THERMOSTAT (OPTIONAL)
FROST THERMOSTAT (OPTIONAL)
HW HIGH FLAME
HOT WATER TEMPERATURE SENSOR (THERMISTOR)
HW
GAS INLET PRESSURE
HW HIGH FLAME
MAIN DRIVER BOARD
LOW FLAME CORRECT PRESSURE
MODUREG PRESSURE REDUCING VALVE
DIVERTER VALVE
CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)
DIVERTER VALVE
HOT WATER TEMPERATURE SENSOR (THERMISTOR)
PUMP
CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)
PUMP
HOT WATER TEMPERATURE SENSOR (THERMISTOR)
GAS INLET PRESSURE
GAS INLET PRESSURE
CH HIGH FLAME
CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)
MODUREG VOLTAGE CH
TEMPERATURE CONTROL POTENTIOMETER
POWER ON INDICATOR
STANDBY INDICATOR NEON (AMBER)
CH DEMAND INDICATOR
DEMAND INDICATOR NEON (GREEN)
FUSE F1
FUSE F1
POWER ON INDICATOR
MAINS FUSE
OPERATING SWITCH
OPERATING SWITCH / PROGRAMMER
FUSE INVESTIGATION
WATER PUMP
FUSE INVESTIGATION
FAN ASSEMBLY
FUSE INVESTIGATION
WATER DIVERTER VALVE
FUSE INVESTIGATION
MAIN GAS VALVE
CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)
CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)
AIR PRESSURE SWITCH: NO AIR
AIR PRESSURE SWITCH
AIR PRESSURE SWITCH:NO AIR
IGNITION CONTROL BOARD
FLUE ASSEMBLY
FLUE ASSEMBLY
AIR PRESSURE SWITCH TUBES
AIR PRESSURE SWITCH TUBES
PILOT NOT IGNITE
FAN ASSEMBLY
PILOT
GAS INLET PRESSURE
HW DEMAND INDICATOR
WATER SUPPLY
HW DEMAND INDICATOR
FILTER - GAUZE
HW DEMAND INDICATOR
ISOLATING VALVE (DHW)
HW DEMAND INDICATOR
FLOW REGULATOR
PUMP OVERRUN
CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)
DIVERTER VALVE ARM CH
WATER FLOW SWITCH STUCK
CH PILOT IGNITES
ELECTRODE LEAD (SPARK)
CH PILOT IGNITES
ELECTRODE (PILOT SPARK)
PILOT VOLTAGE
IGNITION CONTROL BOARD
CH PILOT IGNITES
PILOT INJECTOR
ELECTRODE (FLAME SENSE)
ELECTRODE (FLAME SENSE)
MAIN GAS VALVE
MAIN GAS VALVE
ELECTRODE LEAD (FLAME SENSE)
ELECTRODE LEAD (FLAME SENSE)
FLOW SWITCH HW DEMAND
OPERATING SWITCH / PROGRAMMER
HW SENSOR
MAIN DRIVER BOARD
SECONDARY HEAT EXCHANGER (WATER TO WATER)
SECONDARY HEAT EXCHANGER (WATER TO WATER)
DIVERTER VALVE ARM CH
WATER DIVERTER VALVE
HOT WATER
WATER DIVERTER VALVE
HW SENSOR 2
MAIN DRIVER BOARD
CH SENSOR
MAIN DRIVER BOARD
CH MODULATION
MAIN DRIVER BOARD
HW HIGH FLAME
MODUREG PRESSURE REDUCING VALVE
WATER PUMP VOLTAGE
MAIN DRIVER BOARD
MODUREG PRESSURE REDUCING VALVE
MODUREG PRESSURE REDUCING VALVE
CH SENSOR 2
MAIN DRIVER BOARD
FAULTY POWER NEON
Z REDIRECT
FAULTY DEMAND NEON
Z REDIRECT
FUSE INVESTIGATION F1
Z REDIRECT
MAINS ELECTRICITY SUPPLY
MAINS ELECTRICITY SUPPLY
MAINS FUSE
Z REDIRECT
NO FAULT FUSE INVESTIGATION
FUSE FURTHER INVESTIGATION
ROOM THERMOSTAT
ROOM THERMOSTAT
CH PILOT PASSING
MAIN GAS VALVE
OVERHEAT THERMOSTAT
OVERHEAT THERMOSTAT
PUMP OVERRUN
MAIN DRIVER BOARD
FAN ASSEMBLY
FAN ASSEMBLY
FLUE
AIR PRESSURE SWITCH
WATER FLOW SWITCH (PROXIMITY SWITCH)
WATER FLOW SWITCH (PROXIMITY SWITCH)
HW DEMAND INDICATOR
SECONDARY HEAT EXCHANGER (WATER TO WATER)
PUMP OVERRUN PRIMARY TEST
MAIN DRIVER BOARD
WATER PUMP VOLTAGE 1
MAIN DRIVER BOARD
SPARK GENERATOR
IGNITION CONTROL BOARD
CH PILOT IGNITES
PILOT VALVE (MAIN GAS VALVE)
WATER PUMP
WATER PUMP
SENSE ELECTRODE
IGNITION CONTROL BOARD
MAIN BURNER
MAIN BURNER
PRIMARY HEAT EXANGER (GAS TO WATER)
PRIMARY HEAT EXCHANGER (GAS TO WATER)
HOT WATER UNSATISFACTORY RADIATORS REMAIN COLD
CHARACTERISTIC TEST FROM HOT WATER
HOW WATER UNSATISFACTORY RADIATORS GET WARM
CHARACTERISTIC TEST FROM HOT WATER
PILOT PERMANENTLY LIT
CHARACTERISTIC TEST FROM CH PILOT IGNITES
PILOT DOES NOT LIGHT
CHARACTERISTIC TEST FROM CH PILOT IGNITES
HEAT EXCHANGER NOISY
CHARACTERISTIC TEST FROM CENTRAL HEATING
HEAT EXCHANGER QUIET
CHARACTERISTIC TEST FROM CENTRAL HEATING
24/08/2018 13:36:07 1808_1_50_1 20/09/2018 10:51:17
24/08/2018 14:06:10
FLOW SWITCH HW DEMAND
REMOVE PLUG X1 FROM PCB & TEST AT PLUG
TURN ON HOT WATER TAP
RESISTANCE HW SENSOR
REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.
RESISTANCE CH SENSOR
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD
PRESSURE GAS INLET HW
ATTACH U GAUGE TO INLET PRESSURE TEST POINT
RESISTANCE CH SENSOR
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD
RESISTANCE CH SENSOR
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD
DEMAND VOLTAGE
{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.
PRESSURE GAS INLET
ATTACH U GAUGE TO INLET TEST POINT ON GAS VALVE
OPERATING SWITCH
OPERATING SWITCH IN THE HEATING & WATER POSITION
TEMPERATURE POTENTIOMETER
REMOVE THE PLUG FROM CONNECTOR X9 ON THE MAIN DRIVER BOARD
RESISTANCE MAINS FUSE
REMOVE THE FUSE FROM THE FUSED SPUR
RESISTANCE PUMP
DISCONNECT 4 PIN CONNECTOR X6 MARKED "PUMP" ON MAIN DRIVER BOARD
IGNITION CONTROL BOARD LIVE
{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.
SENSOR CHECK RELAY OPERATION
OPERATING SWITCH IN HEATING & WATER POSITION
DIVERTER VALVE MOTOR VOLTAGE
{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION
RESISTANCE CH SENSOR
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD
RESISTANCE CH SENSOR
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD
WATER PUMP VOLTAGE
{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.
MAIN GAS VALVE VOLTAGE
{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.
RESISTANCE HW SENSOR
REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.
RESISTANCE CH SENSOR
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD
TEMPERATURE POTENTIOMETER
REMOVE THE PLUG FROM CONNECTOR X9 ON THE MAIN DRIVER BOARD
RESISTANCE HW SENSOR
REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.
VOLTAGE MODUREG HW
{GAINPCBACS}
ALLOW MAIN BURNER TO ESTABLISH
RESISTANCE HW SENSOR
REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.
MAINS POWER INPUT
{GAINPCBACS}
RESISTANCE HW SENSOR
REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.
RESISTANCE CH SENSOR
REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD
MODUREG VOLTAGE CH
{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.
RESISTANCE FAN
DISCONNECT 5 PIN CONNECTOR MARKED CN5 ON THE IGNITION PCB
RESISTANCE DIVERTER VALVE
DISCONNECT 4 PIN CONNECTOR X6 MARKED "DIV VALVE" ON MAIN DRIVER BOARD
RESISTANCE GAS VALVE
DISCONNECT 9 PIN CONNECTOR MARKED CN3 ON THE IGNITION PCB
FAN RUNNING
OPERATING SWITCH IN HEATING & WATER POSITION
REMOVE COMBUSTION CHAMBER COVER
AIR PRESSURE SWITCH: AIR DETECT
{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION
AIR PRESSURE SWITCH: NO AIR
{GAINPCBACS}
DISCONNECT CONNECTOR CN2 FROM THE IGNITION CONTROL BOARD
FAN VOLTAGE
OPERATING SWITCH IN HEATING & WATER POSITION.
INLET PRESSURE
ATTACH U GAUGE TO INLET PRESSURE TEST POINT
INSPECTION AIR PRESSURE TUBES
LOWER CONTROLS PANEL
INSPECTION FAN ASSEMBLY
REMOVE FAN ASSEMBLY FROM BOILER
INSPECTION DHW FILTER
TURN OFF COLD WATER SUPPLY TO APPLIANCE
INSPECTION FLOW REGULATOR
TURN OFF COLD WATER SUPPLY TO APPLIANCE
FLOW SWITCH (NO DEMAND)
REMOVE PLUG X1 FROM PCB & TEST AT PLUG
ENSURE NO DHW DEMAND
PILOT SOLENOID VOLTAGE
{GAINPCBACS}
MAIN GAS VALVE SOLENOID OPERATION
OPERATING SWITCH IN HEATING & WATER POSITION
CONNECT U GAUGE TO BURNER PRESSURE TEST POINT
System Information
- Total Tests: 178
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control