XSol Diagnostic System

Interactive Test Sequence Navigator

Welcome to the XSol Diagnostic System

This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.

Start Diagnostic Sequence

or choose a specific test below:

WORCESTER 280 RSF.

G.C. NUMBER 47 311 1

Next: &20, *

HW TAP TURN OFF

OPERATING SWITCH IN WATER POSITION

Next: &nff, !f116

HOT WATER

Next: &1, ?112, ?114

HW BURNER MODULATION

OPERATING SWITCH IN

Next: &2, f109

HW HIGH FLAME

OPERATING SWITCH IN

Next: &3, f231

HW PILOT IGNITES

OPERATING SWITCH IN WATER POSITION

Next: &4, f104

HW DEMAND INDICATOR

OPERATING SWITCH IN WATER POSITION

Next: &5, f101

PUMP OVERRUN

OPERATING SWITCH IN WATER POSITION
TEMPERATURE CONTROL TO MAX

Next: &6, f382

CENTRAL HEATING

Next: &7, ?97, ?99

CH BURNER MODULATION

OPERATING SWITCH IN

Next: &8, f202

CH HIGH FLAME

OPERATING SWITCH IN

Next: &191, f296

CH LOW FLAME

OPERATING SWITCH IN HEATING & WATER POSITION

Next: &250, f73

WATER PUMP RUNNING

OPERATING SWITCH IN

Next: &131, f39

DIVERTER VALVE ARM CH

OPERATING SWITCH IN HEATING & WATER POSITION.

Next: &14, f34

CH DEMAND INDICATOR

OPERATING SWITCH IN HEATING & WATER POSITION.

Next: &15, f29

POWER ON INDICATOR

Next: &16, f24

FROST THERMOSTAT STATE

{GAINPCBACS}

Next: &17, !f23

SYSTEM CHECKS

PLEASE ENSURE THAT THE FOLLOWING SYSTEM CHECKS ARE COMPLETED.

Next: &18, !f22

WORCESTER 280 RSF.

G.C. NUMBER 47 311 1

Next: &19, !f21

CH PILOT IGNITES

OPERATING SWITCH IN HEATING & WATER POSITION

Next: &12, ?330, ?332

INTERNAL FROST THERMOSTAT

Next: &9, f192

CH LOW FLAME CORRECT PRESSURE

ATTACH U GAUGE TO BURNER PRESSURE TEST POINT
REMOVE THE ONE LEAD FROM THE MODULATING COIL

Next: &10, !f251

FUSE INVESTIGATION TREE

OUTSIDE MODEL

Next: &nff, f321

HW PILOT IGNITES

HOT WATER TEMPERATURE SENSOR (THERMISTOR)

Next: End

HOT WATER TEMPERATURE SENSOR FIXING

HOT WATER TEMPERATURE SENSOR FIXING

Next: End

HW TAP TURN OFF

WATER FLOW SWITCH (PROXIMITY SWITCH)

Next: End

HOT WATER TEMPERATURE SENSOR (THERMISTOR)

HOT WATER TEMPERATURE SENSOR (THERMISTOR)

Next: End

CH SENSOR

CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)

Next: End

CENTRAL HEATING TEMPERATURE SENSOR FIXING

CENTRAL HEATING TEMPERATURE SENSOR FIXING

Next: End

CH MODULATION

CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)

Next: End

TEMPERATURE CONTROL POTENTIOMETER

TEMPERATURE CONTROL POTENTIOMETER

Next: End

ELECTRICAL SAFETY CHECK

ELECTRICAL SAFETY CHECK

Next: End

SYSTEM CHECKS

SYSTEM CHECKS

Next: End

FROST THERMOSTAT (OPTIONAL)

FROST THERMOSTAT (OPTIONAL)

Next: End

HW HIGH FLAME

HOT WATER TEMPERATURE SENSOR (THERMISTOR)

Next: End

HW

GAS INLET PRESSURE

Next: End

HW HIGH FLAME

MAIN DRIVER BOARD

Next: End

LOW FLAME CORRECT PRESSURE

MODUREG PRESSURE REDUCING VALVE

Next: End

DIVERTER VALVE

CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)

Next: End

DIVERTER VALVE

HOT WATER TEMPERATURE SENSOR (THERMISTOR)

Next: End

PUMP

CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)

Next: End

PUMP

HOT WATER TEMPERATURE SENSOR (THERMISTOR)

Next: End

GAS INLET PRESSURE

GAS INLET PRESSURE

Next: End

CH HIGH FLAME

CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)

Next: End

MODUREG VOLTAGE CH

TEMPERATURE CONTROL POTENTIOMETER

Next: End

POWER ON INDICATOR

STANDBY INDICATOR NEON (AMBER)

Next: End

CH DEMAND INDICATOR

DEMAND INDICATOR NEON (GREEN)

Next: End

FUSE F1

FUSE F1

Next: End

POWER ON INDICATOR

MAINS FUSE

Next: End

OPERATING SWITCH

OPERATING SWITCH / PROGRAMMER

Next: End

FUSE INVESTIGATION

WATER PUMP

Next: End

FUSE INVESTIGATION

FAN ASSEMBLY

Next: End

FUSE INVESTIGATION

WATER DIVERTER VALVE

Next: End

FUSE INVESTIGATION

MAIN GAS VALVE

Next: End

CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)

CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)

Next: End

AIR PRESSURE SWITCH: NO AIR

AIR PRESSURE SWITCH

Next: End

AIR PRESSURE SWITCH:NO AIR

IGNITION CONTROL BOARD

Next: End

FLUE ASSEMBLY

FLUE ASSEMBLY

Next: End

AIR PRESSURE SWITCH TUBES

AIR PRESSURE SWITCH TUBES

Next: End

PILOT NOT IGNITE

FAN ASSEMBLY

Next: End

PILOT

GAS INLET PRESSURE

Next: End

HW DEMAND INDICATOR

WATER SUPPLY

Next: End

HW DEMAND INDICATOR

FILTER - GAUZE

Next: End

HW DEMAND INDICATOR

ISOLATING VALVE (DHW)

Next: End

HW DEMAND INDICATOR

FLOW REGULATOR

Next: End

PUMP OVERRUN

CENTRAL HEATING TEMPERATURE SENSOR (THERMISTOR)

Next: End

DIVERTER VALVE ARM CH

WATER FLOW SWITCH STUCK

Next: End

CH PILOT IGNITES

ELECTRODE LEAD (SPARK)

Next: End

CH PILOT IGNITES

ELECTRODE (PILOT SPARK)

Next: End

PILOT VOLTAGE

IGNITION CONTROL BOARD

Next: End

CH PILOT IGNITES

PILOT INJECTOR

Next: End

ELECTRODE (FLAME SENSE)

ELECTRODE (FLAME SENSE)

Next: End

MAIN GAS VALVE

MAIN GAS VALVE

Next: End

ELECTRODE LEAD (FLAME SENSE)

ELECTRODE LEAD (FLAME SENSE)

Next: End

SYSTEM FAULT

Next: End

FLOW SWITCH HW DEMAND

OPERATING SWITCH / PROGRAMMER

Next: End

HW SENSOR

MAIN DRIVER BOARD

Next: End

SECONDARY HEAT EXCHANGER (WATER TO WATER)

SECONDARY HEAT EXCHANGER (WATER TO WATER)

Next: End

DIVERTER VALVE ARM CH

WATER DIVERTER VALVE

Next: End

HOT WATER

WATER DIVERTER VALVE

Next: End

HW SENSOR 2

MAIN DRIVER BOARD

Next: End

CH SENSOR

MAIN DRIVER BOARD

Next: End

CH MODULATION

MAIN DRIVER BOARD

Next: End

HW HIGH FLAME

MODUREG PRESSURE REDUCING VALVE

Next: End

WATER PUMP VOLTAGE

MAIN DRIVER BOARD

Next: End

MODUREG PRESSURE REDUCING VALVE

MODUREG PRESSURE REDUCING VALVE

Next: End

CH SENSOR 2

MAIN DRIVER BOARD

Next: End

FAULTY POWER NEON

Z REDIRECT

Next: End

FAULTY DEMAND NEON

Z REDIRECT

Next: End

FUSE INVESTIGATION F1

Z REDIRECT

Next: End

MAINS ELECTRICITY SUPPLY

MAINS ELECTRICITY SUPPLY

Next: End

MAINS FUSE

Z REDIRECT

Next: End

NO FAULT FUSE INVESTIGATION

FUSE FURTHER INVESTIGATION

Next: End

ROOM THERMOSTAT

ROOM THERMOSTAT

Next: End

CH PILOT PASSING

MAIN GAS VALVE

Next: End

OVERHEAT THERMOSTAT

OVERHEAT THERMOSTAT

Next: End

PUMP OVERRUN

MAIN DRIVER BOARD

Next: End

FAN ASSEMBLY

FAN ASSEMBLY

Next: End

FLUE

AIR PRESSURE SWITCH

Next: End

WATER FLOW SWITCH (PROXIMITY SWITCH)

WATER FLOW SWITCH (PROXIMITY SWITCH)

Next: End

HW DEMAND INDICATOR

SECONDARY HEAT EXCHANGER (WATER TO WATER)

Next: End

PUMP OVERRUN PRIMARY TEST

MAIN DRIVER BOARD

Next: End

WATER PUMP VOLTAGE 1

MAIN DRIVER BOARD

Next: End

SPARK GENERATOR

IGNITION CONTROL BOARD

Next: End

CH PILOT IGNITES

PILOT VALVE (MAIN GAS VALVE)

Next: End

WATER PUMP

WATER PUMP

Next: End

SENSE ELECTRODE

IGNITION CONTROL BOARD

Next: End

MAIN BURNER

MAIN BURNER

Next: End

PRIMARY HEAT EXANGER (GAS TO WATER)

PRIMARY HEAT EXCHANGER (GAS TO WATER)

Next: End

HOT WATER UNSATISFACTORY RADIATORS REMAIN COLD

CHARACTERISTIC TEST FROM HOT WATER

Next: !p113

HOW WATER UNSATISFACTORY RADIATORS GET WARM

CHARACTERISTIC TEST FROM HOT WATER

Next: !p129

PILOT PERMANENTLY LIT

CHARACTERISTIC TEST FROM CH PILOT IGNITES

Next: !p331

PILOT DOES NOT LIGHT

CHARACTERISTIC TEST FROM CH PILOT IGNITES

Next: p334

HEAT EXCHANGER NOISY

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p98

HEAT EXCHANGER QUIET

CHARACTERISTIC TEST FROM CENTRAL HEATING

Next: !p100

FLOW SWITCH HW DEMAND

REMOVE PLUG X1 FROM PCB & TEST AT PLUG
TURN ON HOT WATER TAP

Next: !p103, f365

RESISTANCE HW SENSOR

REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.

Next: !p106, !f105

HW SENSOR FIXING

Next: p160, !f110

RESISTANCE CH SENSOR

REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD

Next: !p193, !f194

CH SENSOR FIXING

Next: p204, !f203

PRESSURE GAS INLET HW

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p232, !f235

FUSE F1

Next: p26, f311

RESISTANCE CH SENSOR

REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD

Next: p256, !f257

RESISTANCE CH SENSOR

REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD

Next: p264, !f265

DEMAND VOLTAGE

{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.

Next: p308, f30

PRESSURE GAS INLET

ATTACH U GAUGE TO INLET TEST POINT ON GAS VALVE

Next: p297, !f298

OPERATING SWITCH

OPERATING SWITCH IN THE HEATING & WATER POSITION

Next: !p33, !f32

TEMPERATURE POTENTIOMETER

REMOVE THE PLUG FROM CONNECTOR X9 ON THE MAIN DRIVER BOARD

Next: !p303, !f304

FUSE FURTHER INVESTIGATION

Next: !p312, !f313

RESISTANCE MAINS FUSE

REMOVE THE FUSE FROM THE FUSED SPUR

Next: !p315, f316

FUSE FURTHER INVESTIGATION

Next: !p317, !f318

RESISTANCE PUMP

DISCONNECT 4 PIN CONNECTOR X6 MARKED "PUMP" ON MAIN DRIVER BOARD

Next: p322, !f325

IGNITION CONTROL BOARD LIVE

{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.

Next: p337, f338

SENSOR CHECK RELAY OPERATION

OPERATING SWITCH IN HEATING & WATER POSITION

Next: !p339, f340

DIVERTER VALVE MOTOR VOLTAGE

{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION

Next: !p118, f255

RESISTANCE CH SENSOR

REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD

Next: !p341, !f342

FLUE

Next: p349, !f350

OBSERVATION DHW FLOW RATE

Next: !p366, f367

RESISTANCE CH SENSOR

REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD

Next: !p383, !f384

WATER PUMP VOLTAGE

{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.

Next: !p41, f263

SPARK ELECTRODE LEAD

Next: p391, !f392

MAIN GAS VALVE VOLTAGE

{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.

Next: p75, f74

SENSE ELECTRODE LEAD

Next: p77, !f95

RESISTANCE HW SENSOR

REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.

Next: !p162, !f161

RESISTANCE CH SENSOR

REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD

Next: p205, !f206

TEMPERATURE POTENTIOMETER

REMOVE THE PLUG FROM CONNECTOR X9 ON THE MAIN DRIVER BOARD

Next: !p207, !f208

RESISTANCE HW SENSOR

REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.

Next: p236, !f234

VOLTAGE MODUREG HW

{GAINPCBACS}
ALLOW MAIN BURNER TO ESTABLISH

Next: !p237, !f238

RESISTANCE HW SENSOR

REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.

Next: p385, !f259

MAINS POWER INPUT

{GAINPCBACS}

Next: p305, f314

RESISTANCE HW SENSOR

REMOVE THE PLUG (RED WIRES) FROM CONNECTOR X10 ON MAIN DRIVER BOARD.

Next: !p266, !f267

RESISTANCE CH SENSOR

REMOVE THE PLUG (WHITE WIRES) FROM CONNECTION X10 ON MAIN DRIVER BOARD

Next: p299, !f300

MODUREG VOLTAGE CH

{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION.

Next: !p301, f302

INFORMATION POWER ON NEON

Next: !p306, !f307

INFORMATION DEMAND NEON

Next: !p309, !f310

RESISTANCE FAN

DISCONNECT 5 PIN CONNECTOR MARKED CN5 ON THE IGNITION PCB

Next: p323, !f326

RESISTANCE DIVERTER VALVE

DISCONNECT 4 PIN CONNECTOR X6 MARKED "DIV VALVE" ON MAIN DRIVER BOARD

Next: p324, !f327

RESISTANCE GAS VALVE

DISCONNECT 9 PIN CONNECTOR MARKED CN3 ON THE IGNITION PCB

Next: !p329, !f328

FAN RUNNING

OPERATING SWITCH IN HEATING & WATER POSITION
REMOVE COMBUSTION CHAMBER COVER

Next: p335, f336

AIR PRESSURE SWITCH: AIR DETECT

{GAINPCBACS}
OPERATING SWITCH IN HEATING & WATER POSITION

Next: p347, f348

AIR PRESSURE SWITCH: NO AIR

{GAINPCBACS}
DISCONNECT CONNECTOR CN2 FROM THE IGNITION CONTROL BOARD

Next: p343, !f344

FAN VOLTAGE

OPERATING SWITCH IN HEATING & WATER POSITION.

Next: !p345, !f346

INLET PRESSURE

ATTACH U GAUGE TO INLET PRESSURE TEST POINT

Next: p388, !f356

INSPECTION AIR PRESSURE TUBES

LOWER CONTROLS PANEL

Next: p351, !f352

INSPECTION FAN ASSEMBLY

REMOVE FAN ASSEMBLY FROM BOILER

Next: !p353, !f354

INSPECTION DHW FILTER

TURN OFF COLD WATER SUPPLY TO APPLIANCE

Next: p377, !f370

INSPECTION DHW ISOLATION VALVE

Next: p369, !f376

INSPECTION FLOW REGULATOR

TURN OFF COLD WATER SUPPLY TO APPLIANCE

Next: !p378, !f381

FLOW SWITCH (NO DEMAND)

REMOVE PLUG X1 FROM PCB & TEST AT PLUG
ENSURE NO DHW DEMAND

Next: !p386, !f387

PILOT SOLENOID VOLTAGE

{GAINPCBACS}

Next: p395, !f396

SPARK ELECTRODE

Next: !p393, !f394

PILOT

Next: !p397, !f398

MAIN GAS VALVE SOLENOID OPERATION

OPERATING SWITCH IN HEATING & WATER POSITION
CONNECT U GAUGE TO BURNER PRESSURE TEST POINT

Next: !p81, !f80

SENSE ELECTRODE

Next: !p79, !f78

System Information

  • Total Tests: 178
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control