Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Allow main burner to establish
Allow main burner to establish
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage across connector X8 connection 1 and connector X8 connection 3 on the Main Driver board.
The voltage should be approximately 20vdc
The voltage should be approximately 20vdc

Isolate as per TOPs P4
and refit as necessary