Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect 4 pin connector X6 marked "Div Valve" on main driver board
Measurement:
Test 1:
Measure the resistance between the left (nearest to earth wire)
blue and brown wires at CN3.
Resistance will vary by gas valve but should be approximately 1 - 7kOhms.
Test 2:
Measure the resistance between the right blue and brown wires at CN3.
Resistance will vary by gas valve but should be approximately 1 - 7kOhms.
Test 3:
Measure the resistance between the brown
and green/yellow (earth) wires at connector X6.
Resistance should be greater than 1M Ohm.
Measure the resistance between the left (nearest to earth wire)
blue and brown wires at CN3.
Resistance will vary by gas valve but should be approximately 1 - 7kOhms.
Test 2:
Measure the resistance between the right blue and brown wires at CN3.
Resistance will vary by gas valve but should be approximately 1 - 7kOhms.
Test 3:
Measure the resistance between the brown
and green/yellow (earth) wires at connector X6.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary