Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect 9 pin connector marked CN3 on the ignition PCB
Measurement:
Test 1:
Measure the resistance between the left (nearest earth wire)
blue and brown wires at CN3.
Resistance should be approximately 3kOhms - 7kOhms.
Test 2:
Measure the resistance between the right
blue and brown wires at CN3.
Resistance should be approximately 1kOhms - 3kOhms.
Test 3:
Measure the resistance between both of the brown wires,
in turn, to a suitable earth point.
Resistance should be greater than 1M Ohm on both wires.
Measure the resistance between the left (nearest earth wire)
blue and brown wires at CN3.
Resistance should be approximately 3kOhms - 7kOhms.
Test 2:
Measure the resistance between the right
blue and brown wires at CN3.
Resistance should be approximately 1kOhms - 3kOhms.
Test 3:
Measure the resistance between both of the brown wires,
in turn, to a suitable earth point.
Resistance should be greater than 1M Ohm on both wires.

Isolate as per TOPs P4
and refit as necessary