Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
CH Demand
Gain access to PCB (use Insulation Mat as required)
Operating Switch in Heating & Water position.
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the DC voltage across connector X8 connection 1 and connector X8 connection 3 on the Main Driver board.
Does the voltage remain at a constant low voltage for up to two minutes and then gradually increase over the next minute?
Voltage will remain low (approx 10vdc) before increasing.
Note:
The appliance must be cold for this test, if the appliance is warm the voltage may not increase above the minimum.