Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use Insulation Mat as required)
Operating Switch in Heating & Water position.
Operating Switch in Heating & Water position.
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage across connector X8 connection 1 and connector X8 connection 3 on the Main Driver board.
Does the voltage remain at a constant low voltage for up to two minutes and then gradually increase over the next minute?
Voltage will remain low (approx 10vdc) before increasing.
Note:
The appliance must be cold for this test, if the appliance is warm the voltage may not increase above the minimum.
Does the voltage remain at a constant low voltage for up to two minutes and then gradually increase over the next minute?
Voltage will remain low (approx 10vdc) before increasing.
Note:
The appliance must be cold for this test, if the appliance is warm the voltage may not increase above the minimum.

Isolate as per TOPs P4
and refit as necessary