or choose a specific test below:

4711639 ARISTON MICROGENUS 32 MFFI HE

WARNING - IMPORTA

Next: &12, *

NO FAULT FOUND

Next: nff

OBSERVATION PUMP OVERRUN

PRE-HEAT SWITCHED OFF (TURN COMFORT SWITCH TO E POSITION)

Next: &nff, !f67

OBSERVATION PREHEAT OPERATION

PRE-HEAT SWITCHED ON

Next: &2, f2394

CH OPERATION

CH TEMPERATURE CONTROL SET TO MAX

Next: &3, ?60, ?62, ?64, ?698

DHW OPERATION

DHW TEMPERATURE SET TO MAX

Next: &2010, ?50, ?52, ?54, ?56

OBSERVATION BOILER REACTS TO CH DEMAND

CH TEMPERATURE CONTROL SET TO MAX
ENSURE BOILER IS COOL

Next: &5, f49

OBSERVATION BURNER IGNITION & ESTABLISH

Next: &6, ?168, ?170, ?852

OBSERVATION FAN RUNS DHW DEMAND

DHW TEMPERATURE SET TO MAX

Next: &72, f1677

TYPE OF DIAGNOSTIC PROCEDURE

PLEASE SELECT FROM O

Next: &36, !f35

CASE REMOVAL


CONTROL PANE

Next: &784, !f13

POWER UP SELF TEST

PRE-HEAT SWITCHED OFF (TURN COMFORT SWITCH TO E POSITION)
ENSURE NO DEMANDS ARE PRESENT

Next: &11, ?17, ?746, ?763, ?2410

OPERATIONAL SEQUENCE

SELECT FROM THE LIST

Next: &38, !f37

DHW FLOW RATE

Next: &9, f794

OBSERVATION PUMP RUNNING

DHW TEMPERATURE SET TO MAX

Next: &8, f73

BOILER INITIAL SETUP

Next: &2151, !f785

OBSERVATION DISPLAY

Next: &14, f985

FURTHER INVESTIGATION FUSE PCB BLOWN

NOT USED

Next: &nff, f2447

FAULT CODE E02

NOT USED

Next: &nff, f1125

FAULT CODE E04 - E05

NOT USED

Next: &nff, f2333

FAULT CODE E06 - E07

NOT USED

Next: &nff, f2342

FAULT CODE E33

NOT USED

Next: &nff, f2286

FAULT CODE E34

NOT USED

Next: &nff, f1169

FAULT CODE E21

NOT USED

Next: &nff, f2351

FAULT CODE E08 - E09

NOT USED

Next: &nff, f2358

FAULT CODE A03

NOT USED

Next: &nff, f1222

FAULT CODE A97 / A98 / A99

NOT USED

Next: &nff, f2299

FAULT CODE A77

NOT USED

Next: &nff, f2491

FAULT CODE E99

NOT USED

Next: &nff, f1391

FAULT CODE A75-A79

NOT USED

Next: &nff, f1396

FAULT CODE E20

NOT USED

Next: &nff, f1452

NO DISPLAY FURTHER INVESTIGATION

INTENTIONALLY BLANK

Next: &nff, f1597

FAULT CODE A90

NOT USED

Next: &nff, f2326

FAULT CODE SC

NOT USED

Next: &nff, f1861

FAULT CODE T5

NOT USED

Next: &nff, f1872

ACTIVATE SC MODE - MAXIMUM OUTPUT


Next: &nff, !f1954

BURNER PRESSURE MODULATION - DHW

ADJUST DHW FLOW RATE

Next: &4, f2001

CONFIRM BURNER PRESSURE MAXIMUM & MINIMUM

ENSURE HOT WATER TEM

Next: &2000, f2011

BURNER PRESSURE MAXIMUM & MINIMUM - CH

ENSURE HOT WATER TEM

Next: &nff, f2073

FAULT CODE E32

NOT USED

Next: &nff, f2144

INSPECTION WATER INGRESS PCB - WIRING CONNECTIONS

GAIN ACCESS TO PCB AND ALL WIRING CONNECTIONS

Next: &984, !f2152

FAULT CODE E02

SYSTEM PRESSURE

Next: End

FAULT CODE E34

AIR PRESSURE TUBES - (TRAP - CONDENSATE)

Next: End

FAULT CODE E34 4

FAN

Next: End

FAULT CODE E34

FLUE

Next: End

FAULT CODE E34

MAIN HEAT EXCHANGER

Next: End

FAULT CODE E34

RESTRICTOR FLUE EXHAUST MANIFOLD

Next: End

FAULT CODE E34

RECUPERATOR

Next: End

FAULT CODE E34 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E34

FAN

Next: End

FAULT CODE A03 2

THERMOSTAT - OVERHEAT 103 °C

Next: End

FAULT CODE A03

SYSTEM PRESSURE

Next: End

FAULT CODE A03 2

PUMP

Next: End

FAULT CODE A03

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A03

CABLE - PCB & PUMP

Next: End

CASE OFF

DIRECTION CHOICE OR CONTINUE

Next: End

FAULT CODE E99

Z REDIRECTION

Next: End

FAULT CODE A75-79

SYSTEM PRESSURE

Next: End

FAULT CODE A75-79

PUMP

Next: End

BURNER PRESSURE MAX - MIN 3

GAS VALVE - HONEYWELL

Next: End

FAULT CODE A75-79 2

THERMOSTAT - LIMIT 90 C

Next: End

FAULT CODE E20

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

PUMP DOES NOT RUN

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FLOW RATE

KIT - SPRING 3 - WAY - DHW

Next: End

PUMP DOES NOT RUN

CABLE - PCB & PUMP

Next: End

FURTHER INVESTIGATION DISPLAY

SYSTEM PRESSURE

Next: End

FURTHER INVESTIGATION DISPLAY

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

FURTHER INVESTIGATION DISPLAY

PROBE - TEMPERATURE - DHW

Next: End

FURTHER INVESTIGATION DISPLAY

THERMOSTAT - LIMIT 90 C

Next: End

FURTHER INVESTIAGTION DISPLAY

THERMOSTAT - OVERHEAT 103 °C

Next: End

FURTHER INVESTIGATION DISPLAY

CONDENSATE EXTERNAL PIPE

Next: End

FURTHER INVESTIGATION DISPLAY

RECUPERATOR

Next: End

FURTHER INVESTIGATION DISPLAY

CABLE - ELEMENT

Next: End

FURTHER INVESTIGATION DISPLAY 4

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

DHW NOT RECOGNISED 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

DHW NOT RECOGNISED

KIT - SPRING 3 - WAY - DHW

Next: End

VOLTAGE FAN LIVE PCB

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAN DOES NOT RUN 2

FAN

Next: End

BURNER DOES NOT IGNITE 2

AIR PRESSURE TUBES - (TRAP - CONDENSATE)

Next: End

FAULT CODE A03 3

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A75 / A79 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER DOES NOT IGNITE

MAIN HEAT EXCHANGER

Next: End

BURNER DOES NOT IGNITE

FLUE

Next: End

BURNER DOES NOT IGNITE

RESTRICTOR FLUE EXHAUST MANIFOLD

Next: End

BURNER DOES NOT IGNITE

RECUPERATOR

Next: End

BURNER PRESSURE MAX - MIN 2

GAS VALVE - HONEYWELL

Next: End

BURNER PRESSURE MAX MIN 2

GAS VALVE - ADJUSTMENT BURNER PRESSURE

Next: End

FAULT CODE A75

GAS VALVE - ADJUSTMENT BURNER PRESSURE

Next: End

FAULT CODE E34 2

AIR PRESSURE TUBES - (TRAP - CONDENSATE)

Next: End

CH OPERATION

KNOB - DHW/CH

Next: End

FAULT CODE T5

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

SC DISPLAYED

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E20

FAULT CODE RESET

Next: End

FAULT CODE E20 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

MAXIMUM MODE SC

Z REDIRECTION

Next: End

DHW RUNS HOT AND COLD 4

PIPE - COMPENSATION

Next: End

DHW RUNS HOT AND COLD 5

GAS VALVE - HONEYWELL

Next: End

DHW RUNS HOT AND COLD 4

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER PRESSURE MAX MIN

INLET PRESSURE

Next: End

DHW RUNS HOT AND COLD 5

PIPE - COMPENSATION

Next: End

BURNER PRESSURE MAX - MIN 5

GAS VALVE - HONEYWELL

Next: End

BURNER PRESSURE MAX MIN 4

GAS VALVE - ADJUSTMENT BURNER PRESSURE

Next: End

FAULT CODE A34

HARNESS-LOW VOLTAGE

Next: End

BURNER DOES NOT IGNITE 4

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A34 4

AIR PRESSURE TUBES - (TRAP - CONDENSATE)

Next: End

FAULT CODE E34 5

FAN

Next: End

FAULT CODE E34 2

FLUE

Next: End

FAULT CODE E34 2

MAIN HEAT EXCHANGER

Next: End

FAULT CODE E34 2

RESTRICTOR FLUE EXHAUST MANIFOLD

Next: End

FAULT CODE E34 2

RECUPERATOR

Next: End

FAULT CODE A34 3

AIR PRESSURE TUBES - (TRAP - CONDENSATE)

Next: End

FAULT CODE A34 2

SWITCH AIR PRESSURE

Next: End

BURNER PRESSURE MAX MIN 1

INLET PRESSURE

Next: End

DHW RUNS HOT AND COLD 6

PIPE - COMPENSATION

Next: End

BURNER PRESSURE MAX - MIN 6

GAS VALVE - HONEYWELL

Next: End

BURNER PRESSURE MAX MIN 5

GAS VALVE - ADJUSTMENT BURNER PRESSURE

Next: End

BURNER DOES NOT IGNITE 2

INLET PRESSURE

Next: End

BURNER DOES NOT IGNITE 4

GAS VALVE - HONEYWELL

Next: End

BURNER DOES NOT IGNITE 4

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER DOES NOT IGNITE

INLET PRESSURE

Next: End

BURNER DOES NOT IGNITE

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER DOES NOT IGNITE

GAS VALVE - HONEYWELL

Next: End

BURNER DOES NOT IGNITE 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER DOES NOT IGNITE 3

INLET PRESSURE

Next: End

BURNER DOES NOT IGNITE 5

GAS VALVE - HONEYWELL

Next: End

BURNER DOES NOT IGNITE 3

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E32

WATER INGRESS

Next: End

FAULT CODE E32

KIT-MODULE (EEPROM CMP3)

Next: End

FAULT CODE E32

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E32 2

WATER INGRESS

Next: End

FAN DOES NOT RUN

SYSTEM PRESSURE

Next: End

FAN DOES NOT RUN

SWITCH AIR PRESSURE

Next: End

FAN DOES NOT RUN

AIR PRESSURE TUBES - (TRAP - CONDENSATE)

Next: End

FAN DOES NOT RUN

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

FAN DOES NOT RUN

PROBE - TEMPERATURE - DHW

Next: End

BOILER COOL RADS COOL 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BOILER AND RADS TEMP LOW

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

DIP SWITCH

DIRECTION CHOICE OR CONTINUE

Next: End

DOES NOT MODULATE

PROBE - TEMPERATURE - DHW

Next: End

DHW OPERATION

KNOB - DHW/CH

Next: End

DHW COOL RADS COOL

PUMP

Next: End

DHW COOL RADS COOL

PROBE - TEMPERATURE - DHW

Next: End

DHW COOL RADS COOL

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

DHW COOL RADS COOL

RECUPERATOR

Next: End

DHW COOL RADS COOL

INLET PRESSURE

Next: End

DHW RUNS HOT AND COLD 3

PIPE - COMPENSATION

Next: End

BURNER PRESSURE MAX - MIN 4

GAS VALVE - HONEYWELL

Next: End

BURNER PRESSURE MAX MIN 3

GAS VALVE - ADJUSTMENT BURNER PRESSURE

Next: End

DHW COOL RADS COOL

INJECTOR

Next: End

DHW COOL RADS COOL

SYSTEM PRESSURE

Next: End

DHW RUNS HOT THEN COLD

PUMP

Next: End

DHW RUNS HOT AND COLD

RECUPERATOR

Next: End

DHW RUNS HOT THEN COLD

PROBE - TEMPERATURE - DHW

Next: End

DHW RUNS HOT THEN COLD

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

DHW RUNS HOT AND COLD

INLET PRESSURE

Next: End

DHW RUNS HOT AND COLD 2

PIPE - COMPENSATION

Next: End

BURNER PRESSURE MAX - MIN

GAS VALVE - HONEYWELL

Next: End

BURNER PRESSURE MAX & MIN

GAS VALVE - ADJUSTMENT BURNER PRESSURE

Next: End

DHW RUNS HOT AND COLD

PIPE - COMPENSATION

Next: End

DHW RUNS HOT AND COLD

GAS VALVE - HONEYWELL

Next: End

DHW RUNS HOT AND COLD

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

DHW RUNS HOT COLD

SYSTEM PRESSURE

Next: End

FAULT CODE E33

SWITCH AIR PRESSURE

Next: End

FAULT CODE E33

AIR PRESSURE TUBES - (TRAP - CONDENSATE)

Next: End

FAULT CODE E33

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A97 - 98 - 99

THERMOSTAT - OVERHEAT 103 °C

Next: End

FAULT CODE A97 - 98 - 99

THERMOSTAT - LIMIT 90 C

Next: End

FAULT CODE A97 - 98 - 99

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

FAULT CODE A97 - 98 - 99

PROBE - TEMPERATURE - DHW

Next: End

FAULT CODE A97 - 98 - 99

SWITCH AIR PRESSURE

Next: End

FAULT CODES A97-A98-A99

AIR PRESSURE TUBES - (TRAP - CONDENSATE)

Next: End

FAULT CODE A97- 98 - 99

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A90

KIT-MODULE (EEPROM CMP3)

Next: End

BURNER DOES NOT IGNITE 2

ELECTRODES - IGNITION

Next: End

FAULT CODE A90

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E04 - E05

PROBE - TEMPERATURE - DHW

Next: End

FAULT CODE E04 - E05

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E06 - E07

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

BURNER DOES NOT IGNITE

ELECTRODES - IGNITION

Next: End

FAULT CODE E06 - E07

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E21

Next: End

FAULT CODE E21

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E08 - E09

KIT-MODULE (EEPROM CMP3)

Next: End

FAULT CODE E08 - E09

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BLOWN STAND BY MODE AT POWER UP

PCB FUSE/S - FUSED SPUR

Next: End

BOILER DOES NOT RESPOND

PCB FUSE/S - FUSED SPUR

Next: End

NO DISPLAY

CABLE - DISPLAY

Next: End

PREHEAT

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

BURNER DOES NOT IGNITE

AIR PRESSURE TUBES - (TRAP - CONDENSATE)

Next: End

DHW NOT RECOGNISED

WIRING - LOW VOLTAGE

Next: End

DISPLAY JUMBLED

KIT-MODULE (EEPROM CMP3)

Next: End

DISPLAY JUMBLED

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER DOES NOT IGNITE

FAN

Next: End

DIP SWITCHES

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAN NOT RUNNING

PCB DIP SWITCH

Next: End

DIP SWITCHES 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

CH TEMPERATURE COOL

PCB DIP SWITCH

Next: End

DIP SWITCHES 3

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E08 - E09

PCB DIP SWITCH

Next: End

FAULT CODE E32 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E32

PCB DIP SWITCH

Next: End

FURTHER INVESTIGATION FUSE PCB 2

MOTOR - 3 - WAY VALVE

Next: End

FURTHER INVESTIGATION FUSE PCB

GAS VALVE - HONEYWELL

Next: End

FURTHER INVESTIGATION FUSE PCB

SPARK GENERATOR

Next: End

PCB FUSE BLOWN

MOTOR - 3 - WAY VALVE AND KIT DIVERTER VALVE

Next: End

FAULT CODE A03

KIT - SPRING 3 - WAY - DHW

Next: End

FAULT CODE A01

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A03

RECUPERATOR

Next: End

FAULT CODE A03

Next: End

FAULT CODE A03

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

A77 REOCCURING

CONDENSATE EXTERNAL PIPE

Next: End

A77 REOCCURING

RECUPERATOR

Next: End

FAULT CODE A77

CONDENSATE EXTERNAL PIPE

Next: End

FAULT CODE A77

RECUPERATOR

Next: End

FAULT CODE A77

CABLE - ELEMENT

Next: End

FAULT CODE A77 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A77 2

CONDENSATE EXTERNAL PIPE

Next: End

FAULT CODE A77 2

RECUPERATOR

Next: End

SPARK POSITION

ELECTRODES - IGNITION

Next: End

BURNER DOES NOT IGNITE 2

MAIN HEAT EXCHANGER

Next: End

TYPE DIAG PROCEDURE

DIRECTION CHOICE OR CONTINUE

Next: End

OPERATIONAL SEQUENCE

DIRECTION CHOICE OR CONTINUE

Next: End

BURNER DOES NOT IGNITE

PIPE - COMPENSATION

Next: End

BURNER DOES NOT IGNITE

BURNER

Next: End

CH DOES NOT REACT TO DEMAND

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

DHW TO HOT

PROBE - TEMPERATURE - DHW

Next: End

DHW TO HOT

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

RADS WARM DHW DEMAND

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

RADS WARM DHW DEMAND

CABLE - MOTOR

Next: End

PUMP OVERRUN

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

CH DOES NOT REACT TO DEMAND 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

CH DOES NOT REACT TO DEMAND 4

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

CH DOES NOT REACT TO DEMAND 3

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

EXCESSIVE SYSTEM PRESSURE

EXPANSION VESSEL

Next: End

RADS DO NOT HEAT

SYSTEM PRESSURE

Next: End

RADS DO NOT HEAT

VALVE ISOLATION FLOW AND RETURN

Next: End

RADS DO NOT HEAT

PUMP

Next: End

RADS DO NOT HEAT

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

RADS DO NOT HEAT

CABLE - MOTOR

Next: End

RADS DO NOT HEAT

KIT - BY-PASS-CH

Next: End

RADS DO NOT HEAT

KIT DIVERTER VALVE

Next: End

SELF TEST

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

SELF TEST

FROST PROTECTION NORMAL OPERATION

Next: End

BOILER FIRES WITH NO DEMAND

DHW SYSTEM

Next: End

BOILER FIRES WITH NO DEMAND

PROBE C/W CLIPS - TEMPERATURE CH

Next: End

INITIAL SET UP

DIRECTION CHOICE OR CONTINUE

Next: End

BOILER FIRES WITH NO DEMAND

KIT - DETECTION - FLOW C/W MAGNET

Next: End

BOILER FIRES WITH NO DEMAND

KIT - SPRING 3 - WAY - DHW

Next: End

FLOW RATE

VALVE 1/2IN - ISOLATION - CW INLET

Next: End

FLOW RATE

COLD WATER SUPPLY

Next: End

BURNER DOES NOT ESTABLISH

PIPE - COMPENSATION

Next: End

BURNER BAFFLES

MAIN HEAT EXCHANGER

Next: End

BURNER DOES NOT ESTABLISH

BURNER

Next: End

BURNER DOES NOT ESTABLISH 2

ELECTRODE DETECTION

Next: End

BURNER DOES NOT ESTABLISH

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER BAFFLES 2

MAIN HEAT EXCHANGER

Next: End

FAULT CODES

Z REDIRECTION

Next: End

FAULT CODE E02

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E02

SWITCH PRESSURE - LOW WATER

Next: End

FAULT CODE E02 2

SWITCH PRESSURE - LOW WATER

Next: End

FAULT CODE E02

3-WAY PRESSURE GAUGE VALVE GROUP

Next: End

FAULT CODE E34 3

FAN

Next: End

FAULT CODE E34 2

FAN

Next: End

FAULT CODE E34

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE E34

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A03

PUMP

Next: End

FAULT CODE A03

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE E99

DIRECTION CHOICE OR CONTINUE

Next: End

FAULT CODE A75-79

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A75-79

THERMOSTAT - LIMIT 90 C

Next: End

FAULT CODE E20

ELECTRODE DETECTION

Next: End

PUMP DOES NOT RUN

PUMP

Next: End

FAULT CODE A03 2

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A03 3

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A03 5

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A75 / A79

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A75-A79 3

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A75-A79 2

HARNESS-LOW VOLTAGE

Next: End

FURTHER INVESTIGATION DISPLAY

SWITCH PRESSURE - LOW WATER

Next: End

FURTHER INVESTIGATION DISPLAY 2

SWITCH PRESSURE - LOW WATER

Next: End

FURTHER INVESTIGATION DISPLAY

3-WAY PRESSURE GAUGE VALVE GROUP

Next: End

FURTHER INVESTIGATION DISPLAY 2

HARNESS-LOW VOLTAGE

Next: End

FURTHER INVESTIGATION DISPLAY 3

HARNESS-LOW VOLTAGE

Next: End

FURTHER INVESTIGATION DISPLAY

Z REDIRECTION

Next: End

FURTHER INVESTIGATION DISPLAY

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FURTHER INVESTIGATION DISPLAY 4

HARNESS-LOW VOLTAGE

Next: End

FURTHER INVESTIGATION DISPLAY 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FURTHER INVESTIGATION DISPLAY 5

HARNESS-LOW VOLTAGE

Next: End

FURTHER INVESTIGATION DISPLAY

CONDENSATE TRAP

Next: End

FURTHER INVESTIGATION 6

HARNESS-LOW VOLTAGE

Next: End

FURTHER INVESTIGATION DISPLAY 3

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FURTHER INVESTIGATION DISPLAY 6

HARNESS-LOW VOLTAGE

Next: End

FURTHER INVESTIAGTION DISPLAY

PCB-WATER SENSOR

Next: End

FURTHER INVESTIGATION DISPLAY 7

HARNESS-LOW VOLTAGE

Next: End

DHW NOT RECOGNISED 3

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

DHW NOT RECOGNISED

KIT - DETECTION - FLOW C/W MAGNET

Next: End

FAN DOES NOT RUN

FAN

Next: End

FAN DOES NOT RUN 2

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A03

MAIN HEAT EXCHANGER - WATER WAYS

Next: End

FAULT CODE A03

PCB-WATER SENSOR

Next: End

FAULT CODE A75-A79

PCB-WATER SENSOR

Next: End

BURNER DOES NOT IGNITE 2

FAN

Next: End

BURNER MAX - MIN 2

Z REDIRECTION

Next: End

BURNER MAX - MIN 3

Z REDIRECTION

Next: End

FAULT CODE A75-A79

Z REDIRECTION

Next: End

FAULT CODE T5

FAULT CODE RESET

Next: End

SC DISPLAYED

FAULT CODE RESET

Next: End

FAULT CODE E20

GAS VALVE - HONEYWELL

Next: End

FAULT CODES

DIRECTION CHOICE OR CONTINUE

Next: End

DHW RUNS HOT AND COLD 6

GAS VALVE - HONEYWELL

Next: End

DHW RUNS HOT AND COLD 7

GAS VALVE - HONEYWELL

Next: End

DHW RUNS HOT AND COLD 5

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

UNABLE TO ACTIVATE SC MODE 3

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER MAX - MIN 5

Z REDIRECTION

Next: End

FAULT CODE E34

SWITCH AIR PRESSURE

Next: End

BURNER DOES NOT IGNITE

SWITCH AIR PRESSURE

Next: End

FAULT CODE E34 6

FAN

Next: End

FAULT CODE A34

FAULT CODE RESET - A34

Next: End

BOILER FIRES NO DEMAND

CLOCK

Next: End

DHW RUNS HOT AND COLD 8

GAS VALVE - HONEYWELL

Next: End

DHW RUNS HOT AND COLD 6

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

UNABLE TO ACTIVATE SC MODE 4

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER MAX - MIN 6

Z REDIRECTION

Next: End

BURNER DOES NOT ESTABLISH 3

Z REDIRECTION

Next: End

BURNER DOES NOT IGNITE 2

GAS VALVE - HONEYWELL

Next: End

BURNER DOES NOT IGNITE

Z REDIRECTION

Next: End

SOLENIOD RESISTANCE OK

GAS VALVE - HONEYWELL / SPARK GENERATOR

Next: End

VALVE SOLENIOD OPEN CCT

GAS VALVE - HONEYWELL

Next: End

VALVE SOLENIOD SHORT CCT

GAS VALVE - HONEYWELL / SPARK GENERATOR

Next: End

BURNER DOES NOT ESTABLISH

Z REDIRECTION

Next: End

BURNER DOES NOT IGNITE 3

GAS VALVE - HONEYWELL

Next: End

FAULT CODE E32

FAULT CODE RESET

Next: End

FAN DOES NOT RUN

SWITCH PRESSURE - LOW WATER

Next: End

FAN DOES NOT RUN 2

SWITCH PRESSURE - LOW WATER

Next: End

FAN DOES NOT RUN

3-WAY PRESSURE GAUGE VALVE GROUP

Next: End

FAN DOES NOT RUN

FAN - VENTURI

Next: End

FAN DOES NOT RUN

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BOILER COOL RADS COOL

Z REDIRECTION

Next: End

BOILER COOL RADS COOL

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

DHW COOL RADS COOL

HEAT EXCHANGER 30KW - SECONDARY

Next: End

DHW COOL RADS COOL

MAIN HEAT EXCHANGER - WATER WAYS

Next: End

DHW RUNS HOT AND COLD 4

GAS VALVE - HONEYWELL

Next: End

DHW RUNS HOT AND COLD 3

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

UNABLE TO ACTIVATE SC MODDE 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER MAX - MIN 4

Z REDIRECTION

Next: End

DHW COOL RADS COOL

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

DHW RUNS HOT THEN COLD

HEAT EXCHANGER 30KW - SECONDARY

Next: End

DHW RUNS HOT THEN COLD

MAIN HEAT EXCHANGER - WATER WAYS

Next: End

DHW RUNS HOT AND COLD 3

GAS VALVE - HONEYWELL

Next: End

DHW RUNS HOT AND COLD 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

UNABLE TO ACTIVATE SC MODE

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER MAX - MIN

Z REDIRECTION

Next: End

DHW RUN HOT THEN COLD

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

DHW RUNS HOT AND COLD 2

GAS VALVE - HONEYWELL

Next: End

FAULT CODE E33

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE E33

FAN - VENTURI

Next: End

FAULT CODE E33

FAULT CODE RESET

Next: End

FAULT CODE A97 - 98 - 99

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A97 - 98 - 99 3

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A97- 98-99 4

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A97 - 98 - 99 2

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A97 - 98 - 99

FAN - VENTURI

Next: End

FAULT CODE A97 - 98 - 99

FAULT CODE RESET

Next: End

FAULT CODE A90

FAULT CODE RESET

Next: End

FAULT CODE E04 - E05

HARNESS-LOW VOLTAGE

Next: End

BURNER DOES NOT IGNITE

SPARK GENERATOR

Next: End

FAULT CODE E04 - E05

FAULT CODE RESET

Next: End

FAULT CODE E06 - E07

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE E06 - E07

FAULT CODE RESET

Next: End

FAULT CODE E21

FAULT CODE RESET

Next: End

FAULT CODE E08 - E09

FAULT CODE RESET

Next: End

FURTHER INVESTIGATION FUSED SPUR

Z REDIRECTION

Next: End

FURTHER INVESTIGATION PCB FUSE

Z REDIRECTION

Next: End

NO DISPLAY 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

RESPONDS NO DISPLAY 2

Z REDIRECTION

Next: End

FURTHER INVESTIGATION DOES NOT RESPOND

Z REDIRECTION

Next: End

NO DISPLAY

PCB - CMP3 DISPLAY

Next: End

BOILER RESPONDS NO DISPLAY

Z REDIRECTION

Next: End

NO DISPLAY

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

PRE-HEAT OPERATION

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAN DOES NOT RUN

WIRING - LOW VOLTAGE

Next: End

FAULT CODE E02

WIRING - LOW VOLTAGE

Next: End

FURTHER INVESTIGATION DISPLAY

WIRING - LOW VOLTAGE

Next: End

BURNER DOES NOT IGNITE

WIRING - LOW VOLTAGE

Next: End

DHW RUNS HOT AND COLD

WIRING - LOW VOLTAGE

Next: End

BURNER DOES NOT IGNITE2

WIRING - LOW VOLTAGE

Next: End

BURNER DOES NOT IGNITE 3

WIRING - LOW VOLTAGE

Next: End

DHW RUNS HOT AND COLD 2

WIRING - LOW VOLTAGE

Next: End

DHW RUNS HOT AND COLD 3

WIRING - LOW VOLTAGE

Next: End

DHW RUNS HOT AND COLD 5

WIRING - LOW VOLTAGE

Next: End

DHW RUNS HOT AND COLD 4

WIRING - LOW VOLTAGE

Next: End

DHW RUNS HOT AND COLD 6

WIRING - LOW VOLTAGE

Next: End

DISPLAY JUMBLED

FAULT CODE RESET

Next: End

DIP SWITCHES

Z REDIRECTION

Next: End

DIP SWITCHES 2

Z REDIRECTION

Next: End

DIP SWITCHES 3

Z REDIRECTION

Next: End

DIP SWITCHES 4

Z REDIRECTION

Next: End

FURTHER INVESTIGATION FUSE SPUR PCB

CABLE - MOTOR

Next: End

FURTHER INVESTIGATION FUSE SPUR PCB

CABLE - PCB & PUMP

Next: End

FUSE FURTHER INVESTIGATION FUSE SPUR PCB

HARNESS-LOW VOLTAGE

Next: End

PCB FUSE FURTHER INVESTIGATION

FUSE FURTHER INVESTIGATION

Next: End

FAULT CODE A03

KIT - DETECTION - FLOW C/W MAGNET

Next: End

FAULT CODE A03

HEAT EXCHANGER 30KW - SECONDARY

Next: End

FAULT CODE A75-79

MAIN HEAT EXCHANGER - WATER WAYS

Next: End

SHUTS DOWN AT CORRECT TEMP

FAULT CODE A03

Next: End

FAULT CODE A03

THERMOSTAT - OVERHEAT 103 °C

Next: End

FAULT CODE A03 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A77 REOCCURING

CONDENSATE TRAP

Next: End

A77 REOCCURING

CABLE - ELEMENT

Next: End

FAULT CODE A77

CONDENSATE TRAP

Next: End

FAULT CODE A77 2

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A77

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FAULT CODE A77

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A77

PCB-WATER SENSOR

Next: End

FAULT CODE A77 3

HARNESS-LOW VOLTAGE

Next: End

FAULT CODE A77 2

CONDENSATE TRAP

Next: End

FAULT CODE A77

FAULT CODE RESET

Next: End

BURNER DOES NOT IGNITE

INJECTOR

Next: End

CH DOES NOT REACT TO DEMAND

CLOCK

Next: End

DHW TO HOT

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

RADS WARM WITH DHW DEMAND

MOTOR - 3 - WAY VALVE

Next: End

EXCESSIVE SYSTEM PRESSURE

PIPE - EXPANSION VESSEL

Next: End

RADS DO NOT HEAT

MOTOR - 3 - WAY VALVE

Next: End

RADS DO NOT HEAT

Next: End

RADS WARM DHW DEMAND

KIT DIVERTER VALVE

Next: End

SELF TEST

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BOILER FIRES WITH NO DEMAND 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BOILER FIRES WITH NO DEMAND

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

FLOW RATE

HEAT EXCHANGER 30KW - SECONDARY

Next: End

BURNER BAFFLES

FLUE

Next: End

BURNER BAFFLES

GASKET - FAN OUTLET

Next: End

BURNER BAFFLES

GASKET - FAN

Next: End

BURNER DOES NOT ESTABLISH

INJECTOR

Next: End

BURNER DOES NOT ESTABLISH

ELECTRODE DETECTION

Next: End

BURNER DOES NOT ESTABLISH 2

PCB - CMP3 - MCU HS MLIMFFLIR HE

Next: End

BURNER BAFFLES 2

FLUE

Next: End

BURNER BAFFLES 2

GASKET - FAN OUTLET

Next: End

BURNER BAFFLES 2

GASKET - FAN

Next: End

BLOCKAGE - LOW WATER PRESSURE SWITCH

CHARACTERISTIC TEST FROM INSPECTION SWITCH WATER PRESSURE MANIFOLD

Next: !p1134

BLOCKAGE - DIVERTER VALVE MANIFOLD

CHARACTERISTIC TEST FROM INSPECTION SWITCH WATER PRESSURE MANIFOLD

Next: !p1136

VOLTAGE ABSENT ON TEST 1 (FAN NEUTRAL)

CHARACTERISTIC TEST FROM VOLTAGE FAN AT PCB (NEUTRAL)

Next: p1195

VOLTAGE PRESENT BUT DOES NOT DROP (FAN NEUTRAL)

CHARACTERISTIC TEST FROM VOLTAGE FAN AT PCB (NEUTRAL)

Next: !p1197

BLOCKAGE - LOW WATER PRESSURE SWITCH

CHARACTERISTIC TEST FROM INSPECTION SWITCH WATER PRESSURE MANIFOLD

Next: !p1606

BLOCKAGE - DIVERTER VALVE MANIFOLD

CHARACTERISTIC TEST FROM INSPECTION SWITCH WATER PRESSURE MANIFOLD

Next: !p1608

VOLTAGE MEASURED 0.9 VDC

CHARACTERISTIC TEST FROM VOLTAGE WATER SENSOR PCB OUTPUT - NO DISPLAY

Next: p1650

VOLTAGE MEASURED 0.6 VDC

CHARACTERISTIC TEST FROM VOLTAGE WATER SENSOR PCB OUTPUT - NO DISPLAY

Next: p1625

VOLTAGE MEASURED 0.4 VDC

CHARACTERISTIC TEST FROM VOLTAGE WATER SENSOR PCB OUTPUT - NO DISPLAY

Next: p1634

VOLTAGE MEASURED 0 VDC

CHARACTERISTIC TEST FROM VOLTAGE WATER SENSOR PCB OUTPUT - NO DISPLAY

Next: p1670

VOLTAGE TEST 2 DOES NOT BEHAVE AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE DHW FLOW SWITCH RETURN AT PCB

Next: p1680

BURNER DOES NOT IGNITE

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p169

VOLTAGE TEST 1 MISSING

CHARACTERISTIC TEST FROM VOLTAGE DHW FLOW SWITCH RETURN AT PCB

Next: !p1682

VOLTAGE ABSENT ON TEST 1 (FAN NEUTRAL)

CHARACTERISTIC TEST FROM VOLTAGE FAN AT PCB (NEUTRAL)

Next: p1693

VOLTAGE PRESENT BUT DOES NOT DROP (FAN NEUTRAL)

CHARACTERISTIC TEST FROM VOLTAGE FAN AT PCB (NEUTRAL)

Next: p2158

FAULT CODE DISPLAYED

CHARACTERISTIC TEST FROM POWER UP SELF TEST

Next: p18

BURNER IGNITES BUT BAFFLES AND/OR FLAME LIFTS OFF

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p911

VOLTAGE NOT AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2025

UNABLE TO ACTIVATE SC MODE

CHARACTERISTIC TEST FROM VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2027

VOLTAGE NOT AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2087

UNABLE TO ACTIVATE SC MODE

CHARACTERISTIC TEST FROM VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2089

RESISTANCE MEASURED OPEN CIRCUIT

CHARACTERISTIC TEST FROM RESISTANCE SOLENOID GAS VALVE

Next: !p2119

RESISTANCE MEASURED SHORT CIRCUIT

CHARACTERISTIC TEST FROM RESISTANCE SOLENOID GAS VALVE

Next: !p2121

BLOCKAGE - LOW WATER PRESSURE SWITCH

CHARACTERISTIC TEST FROM INSPECTION SWITCH WATER PRESSURE MANIFOLD

Next: !p2169

BLOCKAGE - DIVERTER VALVE MANIFOLD

CHARACTERISTIC TEST FROM INSPECTION SWITCH WATER PRESSURE MANIFOLD

Next: !p2171

VOLTAGE NOT AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2233

UNABLE TO ACTIVATE SC MODE

CHARACTERISTIC TEST FROM VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2235

VOLTAGE NOT AS ABOVE

CHARACTERISTIC TEST FROM VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2270

UNABLE TO ACTIVATE SC MODE

CHARACTERISTIC TEST FROM VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2272

BOILER RESPONDS BUT DOES NOT OPERATE CORRECTLY

CHARACTERISTIC TEST FROM OBSERVATION BOILER RESPONDS TO A DEMAND (DISPLAY PCB)

Next: !p2382

BOILER DOES NOT RESPOND

CHARACTERISTIC TEST FROM OBSERVATION BOILER RESPONDS TO A DEMAND (DISPLAY PCB)

Next: !p2384

BOILER RESPONDS BUT DOES NOT OPERATE CORRECTLY

CHARACTERISTIC TEST FROM OBSERVATION BOILER RESPONDS TO A DEMAND (DISPLAY PCB)

Next: !p2390

BOILER DOES NOT RESPOND

CHARACTERISTIC TEST FROM OBSERVATION BOILER RESPONDS TO A DEMAND (DISPLAY PCB)

Next: !p2392

DISPLAY TEXT JUMBLED

CHARACTERISTIC TEST FROM POWER UP SELF TEST

Next: p2413

BOILER GOES TO OVERHEAT - TEMPERATURE BELOW 82°C

CHARACTERISTIC TEST FROM RUN BOILER TO MAX TEMP - DOES OVERHEAT OCCUR

Next: !p2486

BOILER FLOW TEMPERATURE EXCEEDS 82°C AND BOILER STILL FIRED

CHARACTERISTIC TEST FROM RUN BOILER TO MAX TEMP - DOES OVERHEAT OCCUR

Next: p2488

FAULT CODE DOES NOT RESET

CHARACTERISTIC TEST FROM RESET APPLIANCE FAULT CODE A77

Next: p2494

FAULT CODE RESETS BUT A77 IS A REOCURRING ISSUE

CHARACTERISTIC TEST FROM RESET APPLIANCE FAULT CODE A77

Next: p2496

DHW COOL, RADIATORS BEGIN TO HEAT WITH NO CH DEMAND

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p51

DHW COOL, RADIATORS COOL

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p2202

DHW TOO HOT

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p55

DHW RUNS HOT THEN COLD

CHARACTERISTIC TEST FROM DHW OPERATION

Next: p2241

EXCESSIVE SYSTEM PRESSURE RISE

CHARACTERISTIC TEST FROM CH OPERATION

Next: p61

BOILER REACHES TEMPERATURE RADIATORS DO NOT HEAT sufficiently

CHARACTERISTIC TEST FROM CH OPERATION

Next: p63

BOILER DOES NOT REACT TO CH DEMAND

CHARACTERISTIC TEST FROM CH OPERATION

Next: p687

BOILER AND RADIATOR TEMPERATURE LOW

CHARACTERISTIC TEST FROM CH OPERATION

Next: p1838

PUMP RUNS AND/OR BOILER FIRES - DISPLAY SHOWS FLOW TEMPERATURE BELOW 8 °C

CHARACTERISTIC TEST FROM POWER UP SELF TEST

Next: p758

TRIES TO FIRE WITH NO DEMANDS - DISPLAY SHOWS FLOW TEMPERATURE 8°C & ABOVE

CHARACTERISTIC TEST FROM POWER UP SELF TEST

Next: p764

BURNER IGNITES BUT DOES NOT ESTABLISH (SPARKING CONTINUES)

CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITION & ESTABLISH

Next: p853

BURNER DOES NOT CROSS LIGHT CORRECTLY

CHARACTERISTIC TEST FROM OBSERVATION BURNER

Next: p859

BURNER CROSS LIGHTS BUT HAS AN UNSTABLE FLAME PICTURE

CHARACTERISTIC TEST FROM OBSERVATION BURNER

Next: p861

FAN INLET GASKET INSPECTION FAIL

CHARACTERISTIC TEST FROM INSPECTION COMBUSTION GASKETS

Next: !p867

RECUPERATOR OUTLET GASKET INSPECTION FAIL

CHARACTERISTIC TEST FROM INSPECTION COMBUSTION GASKETS

Next: !p869

FAN INLET GASKET INSPECTION FAIL

CHARACTERISTIC TEST FROM INSPECTION COMBUSTION GASKETS

Next: !p921

RECUPERATOR OUTLET GASKET INSPECTION FAIL

CHARACTERISTIC TEST FROM INSPECTION COMBUSTION GASKETS

Next: !p923

OBSERVATION SYSTEM PRESSURE

Next: p1126, !f1127

RESISTANCE SWITCH WATER PRESSURE

DISCONNECT LEADS TO THE LOW WATER PRESSURE SWITCH

Next: !p2398, f1131

INSPECTION SWITCH WATER PRESSURE MANIFOLD

DRAIN SYSTEM WATER F

Next: !p1132, ?1133, ?1135

RESET APPLIANCE - FAULT CODE E34

ENSURE NO DEMANDS ARE PRESENT

Next: p2045, f1171

OBSERVATION FAN RUNS DHW DEMAND

DHW TEMPERATURE SET TO MAX

Next: p1176, f1192

INSPECTION AIR PRESSURE TUBES

REMOVE LEFT HAND SIDE PANEL

Next: p1179, !f1180

VOLTAGE FAN AT PCB (NEUTRAL)

{GAINPCBACS}
ENSURE NO DEMANDS ARE PRESENT

Next: !p1193, ?1194, ?1196

RESET APPLIANCE - FAULT CODE A03

ENSURE BOILER IS COOL AND NO DEMANDS ARE PRESENT

Next: p1225, f1224

RESISTANCE OVERHEAT STAT AND HARNESS

GAIN ACCESS TO SMALL PCB ON THE REAR COVER (WATER SENSOR PCB)

Next: p1510, f1242

RESISTANCE OVERHEAT STAT FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS FROM OVERHEAT STAT

Next: !p1287, !f1244

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: p1256, !f1257

RESET APPLIANCE - FAULT CODE E99

AFTER POWER OFF, WAIT 15 SECONDS BEFORE POWER ON
ENSURE NO DEMANDS ARE PRESENT

Next: !p1399, !f1393

RESET APPLIANCE - FAULT CODE A75 / A79

ENSURE BOILER IS COOL AND NO DEMANDS ARE PRESENT

Next: p1401, f1398

RESISTANCE FLUE OVERHEAT STAT AND HARNESS

REMOVE CONNECTOR CN206 FROM THE PCB
GAIN ACCESS TO SMALL PCB ON THE REAR COVER (CONDENSATE PCB)

Next: p1552, f1403

RESISTANCE FLUE OVERHEAT STAT

REMOVE CONNECTORS FROM FLUE OVERHEAT STAT

Next: !p1404, !f1428

BURNER PRESSURE ADJUSTMENT MAX - MIN - FLUE OVERHEAT

ATTACH PRESSURE GAUG

Next: p1830, !f1413

RESET APPLIANCE - FAULT CODE E20

AFTER POWER OFF, WAIT 15 SECONDS BEFORE POWER ON
ENSURE NO DEMANDS ARE PRESENT

Next: p1453, f1454

OBSERVATION FLAME SENSE LEAD DISCONNECTED

{GAINPCBACS}
DISCONNECT FLAME SENSE LEAD FROM CN900 ON THE PCB
(LEAVE IN A SAFE POSITION)

Next: !p1455, !f1456

VOLTAGE WATER SENSOR OUTPUT - PCB

Next: !p1520, f1521

VOLTAGE WATER SENSOR OUTPUT - PCB

Next: !p1562, f1556

OBSERVATION SYSTEM PRESSURE

Next: p1598, !f1599

RESISTANCE SWITCH WATER PRESSURE

DISCONNECT LEADS TO THE LOW WATER PRESSURE SWITCH

Next: !p2399, f1603

INSPECTION SWITCH WATER PRESSURE MANIFOLD

DRAIN SYSTEM WATER F

Next: !p1604, ?1605, ?1607

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: !p1620, !f1621

RESISTANCE THERMISTOR DHW

REMOVE LEADS TO DHW THERMISTOR

Next: !p1630, !f1631

RESISTANCE FLUE OVERHEAT STAT

REMOVE CONNECTORS FROM FLUE OVERHEAT STAT

Next: !p1640, !f1641

RESISTANCE OVERHEAT STAT FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS FROM OVERHEAT STAT

Next: !p1647, !f1646

RESISTANCE CONDENSATE SENSOR

REMOVE FAN ASSEMBLY

Next: !p1659, !f1660

VOLTAGE DHW FLOW SWITCH RETURN AT PCB

{GAINPCBACS}

Next: p1690, ?1679, ?1681

VOLTAGE SPARK GENERATOR AT PCB

{GAINPCBACS}

Next: p230, f231

BURNER PRESSURE ADJUSTMENT MAX - MIN

ATTACH PRESSURE GAUG

Next: p1826, !f1827

OBSERVATION CANCEL MAXIMUM OUTPUT MODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p1876, !f1877

RESET APPLIANCE FAULT CODE T5

ENSURE NO DEMANDS ARE PRESENT

Next: !p1874, !f1875

INSPECTION PIPE COMPENSATION

Next: p2193, !f2003

RESISTANCE GAS VALVE MODULATION COIL

REMOVE LEADS TO GAS VALVE MODULATION COIL

Next: !p2408, !f2007

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p2012, !f2013

RESISTANCE GAS VALVE MODULATION COIL AND HARNESS

REMOVE CONNECTOR CN203

Next: p2018, f2019

RESISTANCE GAS VALVE MODULATION COIL

REMOVE LEADS TO GAS VALVE MODULATION COIL

Next: !p2407, !f2021

INSPECTION AIR PRESSURE TUBES

REMOVE LEFT HAND SIDE PANEL

Next: p2051, !f2064

BYPASS EXTERNAL CONTROLS - FIRES NO DEMAND

{GAINPCBACS}
LINK OUT EXTERNAL CONTROLS (WIRE LINK)
ENSURE NO DEMANDS ARE PRESENT

Next: !p2069, !f2070

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p2074, !f2075

RESISTANCE GAS VALVE MODULATION COIL AND HARNESS

REMOVE CONNECTOR CN203

Next: p2080, f2081

RESISTANCE GAS VALVE MODULATION COIL

REMOVE LEADS TO GAS VALVE MODULATION COIL

Next: !p2409, !f2083

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p2094, !f2093

RESISTANCE GAS VALVE MODULATION COIL AND HARNESS

REMOVE CONNECTOR CN203

Next: p2097, f2098

RESISTANCE GAS VALVE MODULATION COIL

REMOVE LEADS TO GAS VALVE MODULATION COIL

Next: !p2403, !f2100

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p2105, !f2104

VOLTAGE GAS VALVE AT PCB - MAIN SOLENOID

{GAINPCBACS}

Next: p2108, !f2109

RESISTANCE GAS VALVE MODULATION COIL

REMOVE LEADS TO GAS VALVE MODULATION COIL

Next: !p2401, !f2113

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p2124, !f2123

RESISTANCE GAS VALVE MODULATION COIL AND HARNESS

REMOVE CONNECTOR CN203

Next: p2127, f2128

RESISTANCE GAS VALVE MODULATION COIL

REMOVE LEADS TO GAS VALVE MODULATION COIL

Next: !p2404, !f2130

INSPECTION WATER INGRESS PCB - WIRING CONNECTIONS

GAIN ACCESS TO PCB AND ALL WIRING CONNECTIONS

Next: p2146, !f2145

OBSERVATION SYSTEM PRESSURE

Next: p2163, !f2164

INSPECTION SWITCH WATER PRESSURE MANIFOLD

DRAIN SYSTEM WATER F

Next: !p2167, ?2168, ?2170

DISCONNECT AIR PRESSURE TUBE

REMOVE TUBE TO AIR PRESSURE SWITCH
REMOVE LEADS TO THE AIR PRESSURE SWITCH (NOTE THEIR LOCATIONS)

Next: p2174, !f2175

CH POWER CIRCUIT ADJUSTMENT

{GAINPCBACS}
CH T

Next: !p2187, !f2188

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

CH TEMPERATURE SET T

Next: !p2214, f2215

INSPECTION RECUPERATOR HEAT EXCHANGER

DRAIN PRIMARY CIRCUIT OF WATER
REMOVE FLOW AND RETURN PIPES TO RECUPERATOR HEAT EXCHANGER

Next: !p2216, !f2217

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p2220, !f2221

RESISTANCE GAS VALVE MODULATION COIL AND HARNESS

REMOVE CONNECTOR CN203

Next: p2226, f2227

RESISTANCE GAS VALVE MODULATION COIL

REMOVE LEADS TO GAS VALVE MODULATION COIL

Next: !p2406, !f2229

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

CH TEMPERATURE SET T

Next: !p2247, f2248

INSPECTION RECUPERATOR HEAT EXCHANGER

DRAIN PRIMARY CIRCUIT OF WATER
REMOVE FLOW AND RETURN PIPES TO RECUPERATOR HEAT EXCHANGER

Next: !p2249, !f2250

PRESSURE GAS VALVE INLET

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE INLET TEST POINT

Next: p2257, !f2258

RESISTANCE GAS VALVE MODULATION COIL AND HARNESS

REMOVE CONNECTOR CN203

Next: p2263, f2264

RESISTANCE GAS VALVE MODULATION COIL

REMOVE LEADS TO GAS VALVE MODULATION COIL

Next: !p2405, !f2266

INSPECTION PIPE COMPENSATION

Next: p2277, !f2278

RESISTANCE GAS VALVE MODULATION COIL

REMOVE LEADS TO GAS VALVE MODULATION COIL

Next: !p2402, !f2282

RESISTANCE SWITCH AIR PRESSURE AND HARNESS

REMOVE CONNECTOR CN206 FROM THE PCB

Next: p2296, f2288

RESISTANCE SWITCH AIR PRESSURE

DISCONNECT LEADS TO THE AIR PRESSURE SWITCH (NOTE THEIR LOCATIONS)

Next: !p2289, f2290

DISCONNECT AIR PRESSURE TUBE

REMOVE TUBE TO AIR PRESSURE SWITCH
REMOVE LEADS TO THE AIR PRESSURE SWITCH (NOTE THEIR LOCATIONS)

Next: p2291, !f2292

RESISTANCE OVERHEAT STAT AND HARNESS

GAIN ACCESS TO SMALL PCB ON THE REAR COVER (WATER SENSOR PCB)

Next: p2300, f2301

RESISTANCE OVERHEAT STAT FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS FROM OVERHEAT STAT

Next: p2302, !f2303

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: !p2308, !f2309

PRESSURE DIFFERENTIAL - EXHAUST / AIR INTAKE

ENSURE COMBUSTION CO

Next: p1794, f237

RESISTANCE THERMISTOR DHW

REMOVE LEADS TO DHW THERMISTOR

Next: !p2312, !f2313

RESISTANCE SWITCH AIR PRESSURE

DISCONNECT LEADS TO THE AIR PRESSURE SWITCH (NOTE THEIR LOCATIONS)

Next: !p2316, f2317

DISCONNECT AIR PRESSURE TUBE

REMOVE TUBE TO AIR PRESSURE SWITCH
REMOVE LEADS TO THE AIR PRESSURE SWITCH (NOTE THEIR LOCATIONS)

Next: p2318, !f2319

INSPECTION EEPROM MODULE

Next: p2330, !f2328

RESISTANCE THERMISTOR DHW AND HARNESS

REMOVE CONNECTOR CN201 FROM THE PCB

Next: p2339, f2335

RESISTANCE THERMISTOR DHW

REMOVE LEADS TO DHW THERMISTOR

Next: !p2336, !f2337

RESISTANCE THERMISTOR FLOW AND HARNESS

REMOVE CONNECTOR CN201 FROM THE PCB

Next: p2348, f2344

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: !p2345, !f2346

VOLTAGE SOCKET AND SEE

{GAINPCBACS}

Next: p2355, !f2353

INSPECTION EEPROM MODULE

Next: p2359, !f2360

VOLTAGE MAINS POWER INPUT AT PCB

{GAINPCBACS}

Next: p2373, f2368

RESISTANCE FUSE (FUSED SPUR)

REMOVE FUSE FROM FUSED SPUR

Next: !p2369, f2370

INSPECTION AIR PRESSURE TUBES

REMOVE LEFT HAND SIDE PANEL

Next: p239, !f240

FUSE FURTHER INVESTIGATION FUSED SPUR

THE INFORMATION PROV

Next: !p2371, !f2372

FUSE FURTHER INVESTIGATION PCB FUSES

THE INFORMATION PROV

Next: !p2375, !f2376

OBSERVATION BOILER RESPONDS TO A DEMAND (MAIN PCB)

ENSURE BOILER IS COOL AND NO DEMANDS ARE PRESENT

Next: !p2380, ?2381, ?2383

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: !p2395, !f2396

ADJUSTMENT DIP SWITCHES

Next: p2422, !f2425

ADJUSTMENT DIP SWITCHES

Next: p2428, !f2429

ADJUSTMENT DIP SWITCHES

Next: p2434, !f2435

ADJUSTMENT DIP SWITCHES

Next: p2439, !f2440

INSPECTION DIVERTER VALVE ACTUATOR - FUSE FURTHER INVESTIGATION

REMOVE DIVERTER VALV

Next: p2450, !f2467

RESISTANCE DIVERTER VALVE ACTUATOR

REMOVE DIVERTER VALVE ACTUATOR AND DISCONNECT ELECTRICAL CONNECTOR

Next: !p2453, !f2454

RESISTANCE PUMP

REMOVE ELECTRICAL CONNECTOR TO PUMP ASSEMBLY
GAIN ACCESS TO PUMP ELECTRICAL CONNECTIONS

Next: !p2457, !f2458

RESISTANCE FAN ASSEMBLY - FUSE FURTHER INVESTIGATION

REMOVE LEFT HAND SIDE PANEL
REMOVE ELECTRICAL CONNECTIONS TO FAN ASSEMBLY

Next: !p2461, !f2462

INSPECTION DHW FLOW VALVE

ISOLATE COLD FEED TO

Next: !p2470, !f2471

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

CH TEMPERATURE SET T

Next: !p2477, f2478

INSPECTION RECUPERATOR HEAT EXCHANGER

DRAIN PRIMARY CIRCUIT OF WATER
REMOVE FLOW AND RETURN PIPES TO RECUPERATOR HEAT EXCHANGER

Next: !p2479, !f2480

RESET APPLIANCE FAULT CODE A77

ENSURE NO DEMANDS ARE PRESENT

Next: p2492, ?2493, ?2495

RESISTANCE CONDENSATE SENSOR

REMOVE FAN ASSEMBLY

Next: !p2511, !f2512

VOLTAGE WATER SENSOR OUTPUT - PCB

Next: !p2515, f2516

INSPECTION EXTERNAL CONTROLS FITTED

{GAINPCBACS}

Next: p638, f639

BYPASS INTERNAL CLOCK/PROGRAMMER

REMOVE CONNECTOR CN200 FROM THE PCB (LEAVE IN A SAFE POSITION)

Next: !p686, !f684

BYPASS INTERNAL CLOCK/PROGRAMMER

REMOVE CONNECTOR CN200 FROM THE PCB (LEAVE IN A SAFE POSITION)

Next: !p642, !f643

VOLTAGE ACTUATOR AT PCB

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM THE DIVERTER VALVE ACTUATOR
AND MAKE SAFE

Next: p652, !f653

BYPASS INTERNAL CLOCK/PROGRAMMER

REMOVE CONNECTOR CN200 FROM THE PCB (LEAVE IN A SAFE POSITION)

Next: !p690, !f691

BYPASS INTERNAL CLOCK/PROGRAMMER

REMOVE CONNECTOR CN200 FROM THE PCB (LEAVE IN A SAFE POSITION)

Next: !p694, !f695

VOLTAGE ACTUATOR AT PCB - CH

{GAINPCBACS}
REMOVE ELECTRICAL CONNECTOR FROM THE DIVERTER VALVE ACTUATOR
AND MAKE SAFE

Next: p713, !f714

VOLTAGE PUMP AT PCB

{GAINPCBACS}

Next: p145, !f146

DISCONNECT EXTERNAL CONTROLS

REMOVE WIRES / LINK FROM EXTERNAL CONTROLS TERMINAL CONNECTOR AND MAKE SAFE

Next: p779, f2068

VOLTAGE DETECTION ELECTRODE AT PCB

REMOVE CONNECTOR CN900 (DETECTION ELECTRODE LEAD) FROM THE PCB
ENSURE NO DEMANDS ARE PRESENT

Next: !p888, !f889

VOLTAGE MAINS POWER INPUT AT FUSES

{GAINPCBACS}

Next: p2377, f2365

RESISTANCE SWITCH WATER PRESSURE AND HARNESS

REMOVE CONNECTOR CN203 FROM THE PCB

Next: !p1128, f1129

PRESSURE DIFFERENTIAL - EXHAUST / AIR INTAKE

ENSURE COMBUSTION CO

Next: p1833, f1178

INSPECTION FAN ASSEMBLY

REMOVE LEFT HAND SIDE PANEL
REMOVE FAN ASSEMBLY

Next: p1181, !f1182

INSPECTION FLUE

Next: p1183, !f1184

INSPECTION FLUEWAYS MAIN HEAT EXCHANGER

GAIN ACCESS TO COMBUSTION CHAMBER

Next: p1185, !f1186

INSPECTION RESTRICTOR

GAIN ACCESS TO EXHAUST MANIFOLD

Next: p1187, !f1188

INSPECTION RECUPERATOR FLUEWAYS

DRAIN BOILER PRIMARY SYSTEM WATER
REMOVE RECUPERATOR FROM APPLIANCE

Next: !p1189, !f1190

VOLTAGE FAN AT PCB (LIVE)

Next: p1198, !f1199

RESISTANCE FAN ASSEMBLY

REMOVE LEFT HAND SIDE PANEL
DISCONNECT FAN LEADS

Next: !p1200, !f1201

OBSERVATION SYSTEM PRESSURE

Next: p1247, !f1248

OBSERVATION PUMP RUNNING

DHW TEMPERATURE SET TO MAX

Next: p1249, f1255

PUMP LIMPET

Next: p2468, !f1252

RESISTANCE HARNESS PUMP

REMOVE THE CONNECTOR FROM THE PUMP ASSEMBLY AND CN302 FROM THE PCB

Next: !p1258, !f1259

OBSERVATION SYSTEM PRESSURE

Next: p1406, !f1407

PUMP LIMPET

Next: p1410, !f1409

CONFIRM BURNER PRESSURE MAXIMUM & MINIMUM

ENSURE HOT WATER TEM

Next: p1418, f1411

RUN BOILER TO MAX TEMP - DOES FAULT CODE A75 / A79 OCCUR

CH TEMPERATURE CONTR

Next: !p1837, ?1422, ?1424

RESISTANCE HARNESS PUMP

REMOVE THE CONNECTOR FROM THE PUMP ASSEMBLY AND CN302 FROM THE PCB

Next: !p147, !f148

OBSERVATION GAS VALVE PASSING

ATTACH FGA (PRESSURE OPTION) TO GAS VALVE BURNER PRESSURE TEST POINT

Next: p1470, !f1879

VOLTAGE GAS VALVE - BURNER SHUTS DOWN

{GAINPCBACS}

Next: !p1878, !f1882

VOLTAGE WATER SENSOR PCB OUTPUT - MAIN PCB

{GAINPCBACS}

Next: !p1527, f1516

VOLTAGE WATER SENSOR PCB OUTPUT - MAIN PCB

{GAINPCBACS}

Next: !p1561, f1554

RESISTANCE SWITCH WATER PRESSURE AND HARNESS

REMOVE CONNECTOR CN203 FROM THE PCB

Next: p1609, f1601

VOLTAGE WATER SENSOR PCB OUTPUT - NO DISPLAY

{GAINPCBACS}

Next: p1617, ?1622, ?1624, ?1633, ?1648

RESISTANCE THERMISTOR FLOW AND HARNESS

REMOVE CONNECTOR CN201 FROM THE PCB

Next: p1627, f1619

RESISTANCE OVERHEAT STAT AND HARNESS

GAIN ACCESS TO SMALL PCB ON THE REAR COVER (WATER SENSOR PCB)

Next: !p1644, f1643

RESISTANCE THERMISTOR DHW AND HARNESS - NO DISPLAY

REMOVE CONNECTOR CN201 FROM THE PCB

Next: !p1632, f1629

RESISTANCE FLUE OVERHEAT STAT AND HARNESS

REMOVE CONNECTOR CN206 FROM THE PCB
GAIN ACCESS TO SMALL PCB ON THE REAR COVER (CONDENSATE PCB)

Next: !p1639, f1638

INSPECTION CONDENSATE TRAP & HOSE

NOTE.
TAKE

Next: p1651, f1652

INSPECTION RECUPERATOR - BACKED UP

REMOVE FAN ASSEMBLY<

Next: p1655, !f1656

RESISTANCE SENSOR CONDENSATE AND HARNESS

REMOVE 8 WAY CONNECTOR FROM WATER SENSOR PCB

Next: !p1669, f1658

VOLTAGE WATER SENSOR OUTPUT - PCB

Next: !p1671, f1672

RESISTANCE HARNESS DHW FLOW SWITCH

REMOVE CONNECTORS CN203 FROM THE PCB AND FROM THE DHW FLOW SENSOR

Next: p1685, !f2400

INSPECTION DHW FLOW VALVE

ISOLATE COLD FEED TO

Next: !p1687, !f1688

OBSERVATION SPARKING PRESENT

Next: p492, f175

VOLTAGE FAN AT PCB (NEUTRAL)

{GAINPCBACS}
ENSURE NO DEMANDS ARE PRESENT

Next: !p1691, ?1692, ?1694

VOLTAGE FAN AT PCB (LIVE)

Next: p1717, !f1718

RESISTANCE FAN ASSEMBLY

REMOVE LEFT HAND SIDE PANEL
DISCONNECT FAN LEADS

Next: !p1719, !f1720

INSPECTION AIR PRESSURE TUBES

REMOVE LEFT HAND SIDE PANEL

Next: p2042, !f1796

FAULT CODES

Next: !p19, !f983

INSPECTION FLUEWAYS MAIN HEAT EXCHANGER

GAIN ACCESS TO COMBUSTION CHAMBER

Next: p1813, !f1808

INSPECTION FLUE

Next: p1815, !f1814

INSPECTION RESTRICTOR

GAIN ACCESS TO EXHAUST MANIFOLD

Next: p1816, !f1817

INSPECTION RECUPERATOR FLUEWAYS

DRAIN BOILER PRIMARY SYSTEM WATER
REMOVE RECUPERATOR FROM APPLIANCE

Next: !p1818, !f1819

PRESSURE GAS VALVE BURNER - ADJUSTED CORRECTLY - BAFFLES

THE MAXIMUM AND/OR M

Next: !p1828, !f1829

PRESSURE GAS VALVE - ADJUSTED CORRECTLY - A75 - A79 FAULT CODE

THE MAXIMUM AND/OR M

Next: !p1831, !f1832

INSPECTION AIR PRESSURE TUBES

REMOVE LEFT HAND SIDE PANEL

Next: p2039, !f1835

INSPECTION CH TEMPERATURE CONTROL KNOB

GAIN ACCESS TO PCB

Next: p2182, !f1846

RESISTANCE GAS VALVE MODULATION COIL AND HARNESS

REMOVE CONNECTOR CN203

Next: p2004, f2005

VOLTAGE GAS VALVE MODULATION COIL - DHW

ADJUST DHW FLOW RATE

Next: !p2008, !f2009

INSPECTION PIPE COMPENSATION

Next: p2014, !f2015

BURNER PRESSURE ADJUSTMENT MAX - MIN

ATTACH PRESSURE GAUG

Next: p2016, f2017

PRESSURE GAS VALVE BURNER - ADJUSTED CORRECTLY

THE MAXIMUM AND/OR M

Next: !p2028, !f2029

VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2022, ?2024, ?2026

RESISTANCE HARNESS AIR PRESSURE SWITCH

REMOVE LEADS FROM AIR PRESSURE SWITCH (MAKE A NOTE OF THEIR LOCATION)
REMOVE CN206 FROM THE PCB

Next: !p2040, !f2041

RESISTANCE HARNESS AIR PRESSURE SWITCH

REMOVE LEADS FROM AIR PRESSURE SWITCH (MAKE A NOTE OF THEIR LOCATION)
REMOVE CN206 FROM THE PCB

Next: !p2043, !f2044

PRESSURE DIFFERENTIAL - EXHAUST / AIR INTAKE

ENSURE COMBUSTION CO

Next: p2046, f2050

INSPECTION AIR PRESSURE TUBES

REMOVE LEFT HAND SIDE PANEL

Next: p2048, !f2049

AIR PRESSURE SWITCH PROVING

DISCONNECT LEADS AND TUBE FROM THE AIR PRESSURE SWITCH
(MAKE A NOTE OF THEIR CONNECTIONS)

Next: !p2065, !f2066

INSPECTION FAN ASSEMBLY

REMOVE LEFT HAND SIDE PANEL
REMOVE FAN ASSEMBLY

Next: p2053, !f2054

INSPECTION FLUE

Next: p2055, !f2056

INSPECTION FLUEWAYS MAIN HEAT EXCHANGER

GAIN ACCESS TO COMBUSTION CHAMBER

Next: p2057, !f2058

INSPECTION RESTRICTOR

GAIN ACCESS TO EXHAUST MANIFOLD

Next: p2059, !f2060

INSPECTION RECUPERATOR FLUEWAYS

DRAIN BOILER PRIMARY SYSTEM WATER
REMOVE RECUPERATOR FROM APPLIANCE

Next: !p2061, !f2062

INSPECTION PIPE COMPENSATION

Next: p2076, !f2077

BURNER PRESSURE ADJUSTMENT MAX - MIN

ATTACH PRESSURE GAUG

Next: p2078, f2079

PRESSURE GAS VALVE BURNER - ADJUSTED CORRECTLY - CH

THE MAXIMUM AND/OR M

Next: !p2090, !f2091

VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2084, ?2086, ?2088

ADJUSTMENT SOFT - LIGHT IGNITION GAS PRESSURE

DISCONNECT THE DETEC

Next: !p2095, f2096

VOLTAGE GAS VALVE MODULATION COIL

SET SOFT LIGHT POTENTIOMETER TO ITS MID POSITION

Next: !p2101, !f2102

ADJUSTMENT SOFT - LIGHT IGNITION GAS PRESSURE

DISCONNECT THE DETEC

Next: !p2106, f2107

RESISTANCE GAS VALVE MODULATION COIL AND HARNESS

REMOVE CONNECTOR CN203

Next: p2110, f2111

VOLTAGE GAS VALVE MODULATION COIL

SET SOFT LIGHT POTENTIOMETER TO ITS MID POSITION

Next: p2114, !f2115

RESISTANCE SOLENOID GAS VALVE

REMOVE SPARK GENERATOR FROM GAS VALVE

Next: !p2116, ?2118, ?2120

ADJUSTMENT SOFT - LIGHT IGNITION GAS PRESSURE

DISCONNECT THE DETEC

Next: !p2125, f2126

VOLTAGE GAS VALVE MODULATION COIL

SET SOFT LIGHT POTENTIOMETER TO ITS MID POSITION

Next: !p2131, !f2132

INSPECTION EEPROM MODULE

Next: p2153, !f2147

RESET APPLIANCE FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p2149, !f2150

OBSERVATION DIP SWITCH PCB

Next: p2148, f2438

OBSERVATION DIP SWITCH PCB

Next: p2160, f2418

RESISTANCE SWITCH WATER PRESSURE AND HARNESS

REMOVE CONNECTOR CN203 FROM THE PCB

Next: p2161, f2162

RESISTANCE SWITCH AIR PRESSURE

DISCONNECT LEADS TO THE AIR PRESSURE SWITCH (NOTE THEIR LOCATIONS)

Next: p2172, f2173

RESISTANCE SWITCH WATER PRESSURE

DISCONNECT LEADS TO THE LOW WATER PRESSURE SWITCH

Next: !p2397, f2166

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: p2178, !f2179

INSPECTION AIR PRESSURE TUBES

REMOVE LEFT HAND SIDE PANEL

Next: !p2176, !f2177

RESISTANCE THERMISTOR DHW

REMOVE LEADS TO DHW THERMISTOR

Next: !p2180, !f2181

OBSERVATION DIP SWITCH PCB

Next: p2184, f2427

OBSERVATION MAXIMUM HEATING CIRCUIT POWER

CH TEMPERATURE CONTROL SET TO MAX
ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE OUTLET TEST POINT

Next: p2185, f2186

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: !p2189, !f2190

RESISTANCE THERMISTOR DHW

REMOVE LEADS TO DHW THERMISTOR

Next: p2002, !f2201

OBSERVATION SYSTEM PRESSURE

Next: p2203, !f2240

INSPECTION DHW TEMPERATURE CONTROL KNOB

GAIN ACCESS TO PCB

Next: p2204, !f2205

PUMP LIMPET

Next: p2206, !f2207

RESISTANCE THERMISTOR DHW

REMOVE LEADS TO DHW THERMISTOR

Next: p2208, !f2209

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: p2210, !f2211

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - DHW

DHW TEMPERATURE SET

Next: p2212, f2213

CONFIRM BURNER PRESSURE MAXIMUM & MINIMUM

ENSURE HOT WATER TEM

Next: p2218, f2219

INSPECTION BURNER INJECTOR

REMOVE BURNER ASSEMBLY

Next: !p2238, !f2239

INSPECTION PIPE COMPENSATION

Next: p2222, !f2223

BURNER PRESSURE ADJUSTMENT MAX - MIN

ATTACH PRESSURE GAUG

Next: p2224, f2225

PRESSURE GAS VALVE BURNER - ADJUSTED CORRECTLY

THE MAXIMUM AND/OR M

Next: !p2236, !f2237

VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2230, ?2232, ?2234

OBSERVATION SYSTEM PRESSURE

Next: p2242, !f2285

PUMP LIMPET

Next: p2243, !f2244

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - DHW

DHW TEMPERATURE SET

Next: p2245, f2246

RESISTANCE THERMISTOR DHW

REMOVE LEADS TO DHW THERMISTOR

Next: p2251, !f2252

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: p2253, !f2254

CONFIRM BURNER PRESSURE MAXIMUM & MINIMUM

ENSURE HOT WATER TEM

Next: p2255, f2256

BURNER PRESSURE MODULATION - DHW

ADJUST DHW FLOW RATE

Next: !p2275, f2276

INSPECTION PIPE COMPENSATION

Next: p2259, !f2260

BURNER PRESSURE ADJUSTMENT MAX - MIN

ATTACH PRESSURE GAUG

Next: p2261, f2262

PRESSURE GAS VALVE BURNER - ADJUSTED CORRECTLY

THE MAXIMUM AND/OR M

Next: !p2273, !f2274

VOLTAGE GAS VALVE MODULATION COIL - MAX

Next: !p2267, ?2269, ?2271

RESISTANCE GAS VALVE MODULATION COIL AND HARNESS

REMOVE CONNECTOR CN203

Next: p2279, f2280

VOLTAGE GAS VALVE MODULATION COIL - DHW

ADJUST DHW FLOW RATE

Next: !p2283, !f2284

INSPECTION AIR PRESSURE TUBES

REMOVE LEFT HAND SIDE PANEL

Next: !p2293, !f2294

RESET APPLIANCE FAULT CODE E33

ENSURE NO DEMANDS ARE PRESENT

Next: !p2297, !f2298

INSPECTION ELECTRODES

GAIN ACCESS TO ELECTRODE ASSEMBLY

Next: p232, !f233

RESISTANCE THERMISTOR FLOW AND HARNESS

REMOVE CONNECTOR CN201 FROM THE PCB

Next: p2306, f2307

RESISTANCE OVERHEAT STAT FLUE

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLUE OVERHEAT STAT

Next: !p2304, !f2305

RESISTANCE THERMISTOR DHW AND HARNESS

REMOVE CONNECTOR CN201 FROM THE PCB

Next: p2310, f2311

RESISTANCE SWITCH AIR PRESSURE AND HARNESS

REMOVE CONNECTOR CN206 FROM THE PCB

Next: p2323, f2315

INSPECTION AIR PRESSURE TUBES

REMOVE LEFT HAND SIDE PANEL

Next: !p2320, !f2321

RESISTANCE ELECTRODES SPARK

GAIN ACCESS TO SPARK ELECTRODES
REMOVE ELECTRODE LEADS FROM SPARK GENERATOR

Next: !p234, !f235

RESET APPLIANCE FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p2324, !f2325

RESET APPLIANCE FAULT CODE A90

ENSURE NO DEMANDS ARE PRESENT

Next: !p2331, !f2332

RESET APPLIANCE FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p2340, !f2341

RESET APPLIANCE FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p2349, !f2350

RESET APPLIANCE FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p2356, !f2357

OBSERVATION DIP SWITCH PCB

Next: p2361, f2433

RESET APPLIANCE FAULT CODE

ENSURE NO DEMANDS ARE PRESENT

Next: !p2362, !f2363

RESISTANCE FUSES PCB

REMOVE BOTH FUSES FROM PCB

Next: !p2393, f2374

VOLTAGE DISPLAY AT MAIN PCB

Next: p2378, f2379

RESISTANCE CABLE DISPLAY

REMOVE RIBBON CABLE BETWEEN THE DISPLAY & MAIN PCBS

Next: p2385, !f2386

OBSERVATION BOILER RESPONDS TO A DEMAND (DISPLAY PCB)

ENSURE BOILER IS COOL AND NO DEMANDS ARE PRESENT

Next: !p2387, ?2389, ?2391

INSPECTION FAN ASSEMBLY

REMOVE LEFT HAND SIDE PANEL
REMOVE FAN ASSEMBLY

Next: p1806, !f242

INSPECTION EEPROM MODULE

Next: p2414, !f2415

RESET APPLIANCE - DISPLAY JUMBLED

ENSURE NO DEMANDS ARE PRESENT

Next: !p2416, !f2417

DIP SWITCHES SET CORRECTLY - FAN

THE PCB DIP SWITCH S

Next: !p2423, !f2426

DIP SWITCHES SET CORRECTLY - CH TEMPERATURE LOW

THE PCB DIP SWITCH S

Next: !p2430, !f2431

DIP SWITCHES SET CORRECTLY - FAULT CODE E08 - E09

THE PCB DIP SWITCH S

Next: !p2436, !f2437

DIP SWITCHES SET CORRECTLY - FAULT CODE E32

THE PCB DIP SWITCH S

Next: !p2441, !f2442

RESISTANCE DIVERTER VALVE ACTUATOR AND HARNESS

REMOVE CONNECTOR CN303 FROM THE PCB

Next: p2451, f2452

RESISTANCE PUMP AND HARNESS

REMOVE CONNECTOR CN302 FROM THE PCB

Next: p2455, f2456

RESISTANCE FAN ASSEMBLY AND HARNESS

REMOVE CONNECTOR CN302 FROM THE PCB

Next: p2459, f2460

RESISTANCE GAS VALVE

REMOVE SPARK GENERATOR FROM GAS VALVE

Next: p2463, !f2464

RESISTANCE SPARK GENERATOR

REMOVE CONNECTOR CN302 FROM THE PCB

Next: !p2465, !f2466

OBSERVATION DHW END OF DEMAND RECOGNISED

PRE-HEAT SWITCHED OFF (TURN COMFORT SWITCH TO E POSITION)

Next: p2472, f2469

OBSERVATION PUMP OVERRUN

PRE-HEAT SWITCHED OFF (TURN COMFORT SWITCH TO E POSITION)

Next: p2473, !f2474

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - DHW

DHW TEMPERATURE SET

Next: p2475, f2476

TEMPERATURE DIFFERENTIAL FLOW AND RETURN - CH

CH TEMPERATURE SET T

Next: p2481, !f2482

RUN BOILER TO MAX TEMP - DOES OVERHEAT OCCUR

ATTACH TEMPERATURE CLAMP TO PRIMARY HEAT EXCHANGER
FLOW PIPE AS ILLUSTRATED

Next: !p2483, ?2485, ?2487

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: !p2489, !f2490

INSPECTION CONDENSATE TRAP & HOSE

NOTE.
TAKE

Next: p2521, f2522

INSPECTION CONDENSATE TRAP & HOSE

NOTE.
TAKE

Next: p2503, f2504

INSPECTION CONDENSATE TRAP & HOSE

NOTE.
TAKE

Next: p2497, f2498

INSPECTION RECUPERATOR - BACKED UP

REMOVE FAN ASSEMBLY<

Next: !p2501, !f2502

INSPECTION RECUPERATOR - BACKED UP

REMOVE FAN ASSEMBLY<

Next: p2507, !f2508

RESISTANCE SENSOR CONDENSATE AND HARNESS

REMOVE 8 WAY CONNECTOR FROM WATER SENSOR PCB

Next: p2509, f2510

VOLTAGE WATER SENSOR PCB OUTPUT - MAIN PCB

{GAINPCBACS}

Next: !p2513, f2514

INSPECTION RECUPERATOR - BACKED UP

REMOVE FAN ASSEMBLY<

Next: !p2525, !f2526

PRESSURE GAS VALVE SOFT - LIGHT

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE OUTLET TEST POINT

Next: p286, f2103

OBSERVATION ELECTRODE SPARK POSITION

GAIN ACCESS TO THE COMBUSTION CHAMBER

Next: p293, !f294

INSPECTION FLUEWAYS MAIN HEAT EXCHANGER

GAIN ACCESS TO COMBUSTION CHAMBER

Next: p568, !f296

INSPECTION PIPE COMPENSATION

Next: p285, !f514

OBSERVATION DIVERTER VALVE ACTUATOR - DHW

REMOVE DIVERTER VALV

Next: !p723, f651

RESISTANCE THERMISTOR DHW

REMOVE LEADS TO DHW THERMISTOR

Next: p646, !f647

INSPECTION BURNER ASSEMBLY

GAIN ACCESS TO BURNER ASSEMBLY

Next: !p569, !f570

INSPECTION EXPANSION VESSEL PRESSURE

DISCHARGE PRIMARY SYSTEM WATER

Next: !p696, !f697

OBSERVATION SYSTEM PRESSURE

Next: p702, !f703

BYPASS EXTERNAL CONTROLS

{GAINPCBACS}
DISC

Next: !p640, f641

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: !p648, !f649

RESISTANCE HARNESS ACTUATOR

REMOVE CONNECTOR CN303 FROM THE PCB AND ELECTRICAL CONNECTOR TO THE DIVERTER VALVE ACTUATOR

Next: !p654, !f655

INSPECTION EXTERNAL CONTROLS FITTED

{GAINPCBACS}

Next: p688, f689

BYPASS EXTERNAL CONTROLS

{GAINPCBACS}
DISC

Next: !p692, f693

OBSERVATION DIVERTER VALVE ACTUATOR - CH

REMOVE DIVERTER VALV

Next: p724, f707

TEMPERATURE DIFFERENTIAL INTERNAL BYPASS

ENSURE RADIATORS ARE

Next: !p717, !f718

PUMP LIMPET

Next: p704, !f712

RESISTANCE HARNESS ACTUATOR

REMOVE CONNECTOR CN303 FROM THE PCB AND ELECTRICAL CONNECTOR TO THE DIVERTER VALVE ACTUATOR

Next: !p715, !f716

INSPECTION DIVERTER VALVE SPINDLE

REMOVE DIVERTER VALVE ACTUATOR

Next: p706, !f728

TEMPERATURE FLOW - FROST PROTECTION

REMOVE LEFT HAND SID

Next: p759, !f762

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: !p760, !f761

OBSERVATION DEMAND ILLUMINATED

PRE-HEAT SWITCHED OFF (TURN COMFORT SWITCH TO E POSITION)
ENSURE NO DEMANDS ARE PRESENT

Next: p771, f766

OBSERVATION ISOLATE COLD FEED TO BOILER

ISOLATE DHW COLD FEED

Next: p772, !f773

OBSERVATION REMOVE DHW FLOW SWITCH

REMOVE DHW FLOW SENS

Next: p787, !f793

RESISTANCE THERMISTOR FLOW

REMOVE LEFT HAND SIDE PANEL
REMOVE LEADS TO FLOW THERMISTOR

Next: !p781, !f782

OBSERVATION DISCONNECT DHW FLOW SWITCH

REMOVE ELECTRICAL CONNECTOR FROM DHW FLOW SENSOR (LEAVE IN A SAFE PLACE)

Next: !p788, !f792

OBSERVATION COLD WATER SUPPLY

Next: p797, !f798

INSPECTION FLOW VALVE ASSEMBLY DHW

ISOLATE COLD FEED TO

Next: !p799, !f1478

INSPECTION PIPE COMPENSATION

Next: p854, !f855

OBSERVATION BURNER

Next: p856, ?858, ?860

INSPECTION ELECTRODE DETECTION

GAIN ACCESS TO COMBUSTION CHAMBER

Next: p884, !f885

PRESSURE GAS VALVE SOFT - LIGHT

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE OUTLET TEST POINT

Next: p870, f2092

INSPECTION FLUEWAYS MAIN HEAT EXCHANGER

GAIN ACCESS TO COMBUSTION CHAMBER

Next: p862, !f863

INSPECTION COMBUSTION GASKETS

GAIN ACCESS TO COMBUSTION CHAMBER

Next: !p864, ?866, ?868

INSPECTION BURNER ASSEMBLY

GAIN ACCESS TO BURNER ASSEMBLY

Next: !p882, !f883

VOLTAGE ELECTRODE DETECTION

ENSURE NO DEMANDS ARE PRESENT
GAIN ACCESS TO DETECTION ELECTRODE

Next: p886, f887

PRESSURE GAS VALVE SOFT - LIGHT

ATTACH PRESSURE GAUGE TO GAS VALVE PRESSURE OUTLET TEST POINT

Next: !p890, f2122

CONFIRM BURNER PRESSURE MAXIMUM & MINIMUM

ENSURE HOT WATER TEM

Next: p915, f1825

INSPECTION FLUEWAYS MAIN HEAT EXCHANGER

GAIN ACCESS TO COMBUSTION CHAMBER

Next: p916, !f917

INSPECTION COMBUSTION GASKETS

GAIN ACCESS TO COMBUSTION CHAMBER

Next: !p918, ?920, ?922

System Information

  • Total Tests: 841
  • Sequence Logic: Decoded from encrypted .seq file
  • Navigation: Dynamic based on pass/fail results
  • Source: 4731307 GW SWIFTFLOW 100 SIT Control

XSol Diagnostic System - Generated from extracted test data