Set Appliance State:

Mains Power Off
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Set soft light potentiometer to its MID position
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance if required (press reset button for 2 seconds and release).
Allow boiler to commence its ignition sequence.
Measure for DC voltage across the gas valve modulation coil.
Approximately 5 seconds after the fan has started 8 - 12 Vdc
should be present for 7 seconds?
Note.
1. Voltage measured could be either negative or positive.
2. Appliance may enter lockout during this test, reset
as required until test is complete.