Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Attach FGA (pressure option) to gas valve burner pressure test point
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Reset appliance if required (press reset button for 2 seconds and release).
Allow burner to ignite and establish.
After 1 minute turn hot water tap OFF (if tap is not close use cold water isolation valve).
Does the burner extinguish straight away or is there a flame present after the demand has ended?
Allow burner to ignite and establish.
After 1 minute turn hot water tap OFF (if tap is not close use cold water isolation valve).
Does the burner extinguish straight away or is there a flame present after the demand has ended?