VAILLANT TURBOMAX PLUS VUW 837E (VUW GB 362/2-5)
GLOBALLY REPLACED
VAILLANT TURBOMAX PLUS VUW 837E (VUW GB 362/2-5)
GC NO. 47 044 28
PUMP RUNS (CH DEMAND)
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
DOES THE FAN RUN
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
ELECTRODE SPARKING
ON/OFF SWITCH IN ON POSITION
BURNER ESTABLISHED
ON/OFF SWITCH IN ON
DHW MAXIMUM BURNER PRESSURE
ON/OFF SWITCH IN ON
DHW WARMSTART OPERATION
RUN THE HOT TAP UNTIL THE WATER IS COLD
TURN HOT WATER TAP OFF
CH OPERATION
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
BURNER MODULATION
ON/OFF SWITCH IN ON
PUMP OVERRUN
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
ANTI-CYCLE
ON/OFF SWITCH IN ON
F11/F1 FAULT CODE/ RETURN THERMISTOR
OUTSIDE MODEL
F10/F0 FAULT CODE/ FLOW THERMISTOR
OUTSIDE MODEL
F62 FAULT CODE
OUTSIDE MODEL
F20 / F22 / F23 / F24 FAULT CODE
OUTSIDE MODEL
F27 FAULT CODE
OUTSIDE MODEL
F28 / F29 FAULT CODE
OUTSIDE MODEL
F42 / F43 / F60 / F63 / F64 / F65 / F67 FAULT CODE
OUTSIDE MODEL
F61 FAULT CODE
OUTSIDE MODEL
F66 FAULT CODE
OUTSIDE MODEL
FUSE FURTHER INVESTIGATION (DUMMY)
OUTSIDE MODEL
OBSERVATION DISPLAY ILLUMINATES
ON / OFF SWITCH ON
HOW TO SET MULTIMETER TO DIODE
THE IMAGES BELOW SHO
DHW OPERATION
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MIN
DHW TEMP SELECTOR TO MAX
DHW FLOW FLOW RATE
LIMITER
NO PRESSURE SIT VALVE
GAS VALVE AND PCB
LOW PRESSURE
GAS VALVE INLET PRESSURE
F62
GAS SECTION
F61 FAULT CODE
GAS VALVE AND PCB
F61
GAS VALVE AND PCB
FLAME SENSE
WIRING HARNESS CABLE TREE
FLAME SENSE BURNER ESTABLISHED
IGNITION C/W MONITORING ELECTRODE
BURNER
BURNER CHAMBER GROUP
BURNER IGNITES SPARKING CONTINUES THEN LOCKOUT
TUBE - DISTRIBUTOR (BURNER INJECTOR)
BURNER ESTABLISHED
IGNITION C/W MONITORING ELECTRODE - GAP
BLANK FOR FAN INFO PAGE
Z REDIRECT
DHW TOO HOT
SENSOR - NTC
DHW TOO HOT
SET - 3 OFF KNOBS - GREY
WEAK OR SLOW CAUSING KETTLING
PUMP ASSEMBLY - GRUNDFOS VP5
DHW OPERATION
AUTOMATIC BY-PASS
WEAK OR SLOW CAUSING POOR DHW TEMPERATURE RISE
PUMP ASSEMBLY - GRUNDFOS VP5
DHW OPERATION
TUBE - DISTRIBUTOR (BURNER INJECTOR)
DHW OPERATION
PRIMARY HEAT EXCHANGER FLUE WAYS
DHW OPERATION
FLUE
DHW MAXIMUM BURNER PRESSURE
PRIMARY HEAT EXCHANGER FLUE WAYS
DHW FLOW RATE
FILTER - WATER
WARMSTART OPERATION
SENSOR - NTC - WARMSTART
BOILER HEATS BUT RADS COLD
AUTOMATIC BY-PASS
CH OPERATION
PUMP ASSEMBLY - GRUNDFOS VP5
CH NOISY DHW OK
AUTOMATIC BY-PASS
BURNER MODULATION
SENSOR - NTC
PUMP OVERRUN
PCB
ANTI-CYCLE
PCB
OPERATIONAL SEQUENCE
SYSTEM CHECKS
ELECTRICAL SAFETY CHECKS
ELECTRICAL SAFETY
HONEYWELL VALVE
GAS VALVE INLET PRESSURE
NO BURNER PRESSURE
SYSTEM PRESSURE
BURNER ESTABLISHED
GAS VALVE INLET PRESSURE
BURNER EST
WATER PRESSURE SWITCH
BURNER ESTABLISH
HARNESS GAS VALVE AND WATER PRESSURE SWITCH
HONEYWELL ELECTRICAL
GAS SECTION
BURNER DROPS OUT
PRIMARY HEAT EXCHANGER FLUE WAYS
BURNER DROPS OUT
VENTURI
BURNER DROPS OUT
FAN
BURNER DROPS OUT
TUBE - FLEXIBLE
BURNER DROPS OUT
FLUE
CH OP
PCB
FAULT CODES
Z REDIRECT
F11/1 FAULT CODE
SENSOR - NTC
F0/F10 FAULT CODE
SENSOR - NTC
F62 GAS VALVE
GAS SECTION
OVERHEAT
SYSTEM PRESSURE
F20 RUNNING SLOW
PUMP ASSEMBLY - GRUNDFOS VP5
FAN RUNS (CH DEMAND)
TUBE - FLEXIBLE
F20 FAULT CODE
SENSOR - NTC
F20 FAULT CODE
SENSOR - NTC
OVERHEAT3
PCB
FAN RUNS (CH DEMAND)
VENTURI
F27 FAULT CODE
WIRING HARNESS CABLE TREE
F27 FAULT CODE
IGNITION C/W MONITORING ELECTRODE
FAN RUNS (CH DEMAND)
FLUE
F28 FAULT CODE
IGNITION C/W MONITORING ELECTRODE
F28 FAULT CODE
IGNITION C/W MONITORING ELECTRODE - GAP
F60 FAULT CODE
WIRING HARNESS CABLE TREE
F60 FAULT CODE
Z REDIRECT
F66 FAULT CODE
PCB
HARNESS FAN
WIRING HARNESS CABLE TREE
ELECTRODE SPARKING
TUBE - FLEXIBLE
ELECTRODE SPARKING
VENTURI
ELECTRODE SPARKING
FLUE
APS NC
WIRING HARNESS CABLE TREE
ELECTRODE SPARKING
IGNITION C/W MONITORING ELECTRODE
ELECTRODE SPARKING
IGNITION C/W MONITORING ELECTRODE - GAP
BURNER ESTABLISHED ELECTRICAL
GAS SECTION
NO PRESSURE SWITCH
GAS SECTION
NO PRESSURE SWITCH
GAS VALVE INLET PRESSURE
FUSE INVESTIGATION
TRANSFORMER
FUSE INVESTIGATION
PUMP ASSEMBLY - GRUNDFOS VP5
FUSE INV SIT
GAS SECTION
FUSE INV
WATER PRESSURE SWITCH
FUSE INV NO LWPS
CABLE - CONNECTING - GAS SECTION - SIT
NO DISPLAY
MAINS FUSE
NO DISPLAY
SET - 10 OFF FUSES 2.0AT
NO DISPLAY
SET - 10 FUSES 1.25AT
NO DISPLAY
PCB
PUMP RUNS (CH DEMAND)
SENSOR - NTC
PUMP RUNS (CH DEMAND)
SENSOR - NTC
BURNER MODULATION
SET - 3 OFF KNOBS - GREY
HONEYWELL NO VOLTS TO GV R203 OK
CABLE - CONNECTING - GAS SECTION - HONEYWELL
SETTING MULTIMETER TO DIODE
Z REDIRECT
F20 FAULT CODE DHW OPERATION
HEAT EXCHANGER
F20 FAULT CODE MINIMUM
GAS VALVE INLET PRESSURE
F20 FAULT CODE MAXIMUM
GAS VALVE INLET PRESSURE
F20 FAULT CODE CH OPERATION
AUTOMATIC BY-PASS
ELECTRODE SPARKING
SWITCH - FAN PROVING - HUBA
DHW FLOW RATE
VALVE 3/4IN X 15
NO PRESSURE HAS LWPS
GAS VALVE AND PCB
DHW DEMAND
AQUA SENSOR - IMPELLOR ONLY
DHW MAXIMUM BURNER PRESSURE
GAS SECTION
F20 FAULT CODE GAS MODULATION (DHW)
GAS SECTION
F20 FAULT CODE GV MODUREG
WIRING HARNESS CABLE TREE
F20 FAULT CODE
KIT - JUMPER LINK
GV MOD
WIRING HARNESS CABLE TREE
DHW MAXIMUM BURNER PRESSURE
SENSOR - NTC
DHW MAXIMUM BURNER PRESSURE
KIT - JUMPER LINK
DHW MAXIMUM BURNER PRESSURE
GAS VALVE INLET PRESSURE
FUSE INV HONEYWELL HARNESS SHORT
GAS SECTION
FUSE INV HONEYWELL HARNESS OK
GAS SECTION
FUSE INV DIODE FAILURE
CABLE - CONNECTING - GAS SECTION - HONEYWELL
R203 RESISTOR
GAS VALVE AND PCB
RESISTOR R203
GAS VALVE HARNESS AND PCB
LOW PRESSURE
GAS VALVE ADJUSTMENT
F62
F62 NO FAULT FOUND
F62 - NOT SHUTTING DOWN 1
GAS SECTION
F61 GAS VALVE
PCB
F61
PCB
BURNER ESTABLISHED
TUBE - DISTRIBUTOR (BURNER INJECTOR)
DHW TOO HOT
GAS VALVE ADJUSTMENT
DHW TOO HOT
PCB
DHW NOISY OPERATION KETTLES
HEAT EXCHANGER - SECONDARY
DHW OPERATION
HEAT EXCHANGER
DHW OPERATION
VALVE - DIVERTER
DHW COOL RADIATORS HOT
MOTOR - DIVERTER VALVE
DHW COLD RADIATORS COLD
HEAT EXCHANGER - SECONDARY
DHW OPERATION
FAN
SCALED
HEAT EXCHANGER - SECONDARY
WARMSTART
PCB
BOILER HEATS BUT RADS COLD
VALVE - DIVERTER
BURNER MODULATION
GAS SECTION
SYSTEM PRESSURE RISE
EXPANSION VESSEL 10 LITRE - SQUARE
BURNER ESTABLISHED MECHANICAL
GAS SECTION
BURNER DROPS OUT
SWITCH - FAN PROVING - HUBA
PUMP RUNS
PUMP ASSEMBLY - GRUNDFOS VP5
PUMP RUNS
INTEGRAL HEATING CONTROLS
CH OP
MOTOR - DIVERTER VALVE
F11-F1 RETEST BOILER
DIRECTION CHOICE OR CONTINUE
SENSOR TEMP RETURN F11/1 FAULT CODE
WIRING HARNESS CABLE TREE
F10-F0 RETEST BOILER
DIRECTION CHOICE OR CONTINUE
SENSOR PRIMARY F0/F10 FAULT CODE
WIRING HARNESS CABLE TREE
F62 FAULT CODE
F62 NO FAULT FOUND
F62 - NOT SHUTTING DOWN
GAS SECTION
F20 FAULT CODE FLOW SENSOR
WIRING HARNESS CABLE TREE
F20 FAULT CODE RETURN SENSOR
WIRING HARNESS CABLE TREE
F20 FAULT CODE
HEAT EXCHANGER - SECONDARY
F27 FAULT CODE
Z REDIRECT
FAN RUNS (CH DEMAND)
SWITCH - FAN PROVING - HUBA
F28 FAULT CODE
PCB
F28 FAULT CODE
Z REDIRECT
F27 FAULT CODE
PCB
F60 FAULT CODE
PCB
F61 GAS VALVE
GAS SECTION
F66 FAULT CODE
COVER - DISPLAY
F20 NOT RUNNING
PUMP ASSEMBLY - GRUNDFOS VP5
NO PRESSURE SWITCH
GAS VALVE
FUSE INVESTIGATION - FAN
WIRING HARNESS CABLE TREE
SIT VALVE
FUSE INVESTIGATION NO FAULT
FUSE INV
HARNESS GAS VALVE AND WATER PRESSURE SWITCH
NO BURNER PRESSURE NO LWPS
CABLE - CONNECTING - GAS SECTION - SIT
MAINS FUSE
Z REDIRECT
FUSE F1
Z REDIRECT
FUSE F2
Z REDIRECT
NO DISPLAY
TRANSFORMER
NO DISPLAY
COVER - DISPLAY
FLOW SENSOR
WIRING HARNESS CABLE TREE
RETURN SENSOR
WIRING HARNESS CABLE TREE
HONEYWELL MECHANICAL FAULT
GAS SECTION
F20 FAULT CODE MINIMUM
GAS VALVE ADJUSTMENT
F20 INVESTIGATION
OVERHEAT
DHW DEMAND
PCB
DHW DEMAND
SENSOR - HALL
F20 FAULT CODE MAXIMUM
GAS VALVE ADJUSTMENT
GAS MODULATION (DHW)
GAS SECTION
FUSE INV HONEYWELL
CABLE - CONNECTING - GAS SECTION - HONEYWELL
HONEYWELL GAS VALVE
FUSE INVESTIGATION NO FAULT
R203 RESISTER
GAS VALVE HARNESS AND PCB
BOILER RETURNS TO FAULT CODE BEFORE IGNITION
CHARACTERISTIC TEST FROM OBSERVATION BURNER SHUT OFF
BURNER STAYS ALIGHT AFTER DEMAND ENDS OR FAULT CODE OCCURS AFTER DEMAND
CHARACTERISTIC TEST FROM OBSERVATION BURNER SHUT OFF
PRESSURE INCREASES BUT FLAME BAFFLES
CHARACTERISTIC TEST FROM DHW MAXIMUM BURNER PRESSURE
BURNER IGNITES WITH CORRECT BP BUT SPARKING CONTINUES AND BOILER LOCKS OUT
CHARACTERISTIC TEST FROM BURNER ESTABLISHED
PRESSURE DOES NOT REACH MAXIMUM
CHARACTERISTIC TEST FROM DHW MAXIMUM BURNER PRESSURE
BURNER PRESSURE CORRECT, SPARKING PRESENT BUT BURNER FAILS TO IGNITE
CHARACTERISTIC TEST FROM BURNER ESTABLISHED
BURNER BAFFLES OUT DURING OPERATION
CHARACTERISTIC TEST FROM DHW OPERATION
TEMPERATURE RISE UNSATISFACTORY - RADIATORS REMAIN COOL WITH NO CH DEMAND
CHARACTERISTIC TEST FROM DHW OPERATION
TEMPERATURE RISE UNSATISFACTORY - RADIATORS BEGIN TO HEAT WITH NO CH DEMAND
CHARACTERISTIC TEST FROM DHW OPERATION
BOILER NOISY / KETTLING DURING OPERATION
CHARACTERISTIC TEST FROM DHW OPERATION
DHW TOO HOT
CHARACTERISTIC TEST FROM DHW OPERATION
CH NOISY, DHW OK
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
BOILER HEATS, BUT RADS COLD
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
EXCESSIVE SYSTEM PRESSURE RISE
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
PRESSURE INCREASES BUT FLAME DROPS OUT THEN IMMEDIATELY RE-IGNITES
CHARACTERISTIC TEST FROM DHW MAXIMUM BURNER PRESSURE
BOILER RETURNS TO FAULT CODE BEFORE IGNITION
CHARACTERISTIC TEST FROM OBSERVATION BURNER SHUT OFF
BURNER STAYS ALIGHT AFTER DEMAND ENDS OR FAULT CODE OCCURS AFTER DEMAND
CHARACTERISTIC TEST FROM OBSERVATION BURNER SHUT OFF
VOLTAGE PRESENT ON TEST 1 BUT DOES NOT DROP
CHARACTERISTIC TEST FROM AIR PRESSURE SWITCH (AIR DETECT)
VOLTAGE ABSENT ON TEST 1
CHARACTERISTIC TEST FROM AIR PRESSURE SWITCH (AIR DETECT)
BURNER PRESSURE PRESENT BUT BELOW 2MB
CHARACTERISTIC TEST FROM BURNER ESTABLISHED
ONLY MINIMUM PRESSURE IS INCORRECT
CHARACTERISTIC TEST FROM PRESSURE BURNER MAXIMUM AND MINIMUM
MAXIMUM PRESSURE INCORRECT OR BOTH MAX AND MIN INCORRECT
CHARACTERISTIC TEST FROM PRESSURE BURNER MAXIMUM AND MINIMUM
NO BURNER PRESSURE
CHARACTERISTIC TEST FROM BURNER ESTABLISHED
CH NOISY OPERATION / OVERHEATS OR CUTS OUT QUICKLY
CHARACTERISTIC TEST FROM TEMPERATURE CH OPERATION DIFFERENTIAL AND RUN TO MAX
DIFFERENTIAL OK BUT BOILER RETURNS TO FAULT CODE BEFORE REACHING TEMPERATURE
CHARACTERISTIC TEST FROM TEMPERATURE CH OPERATION DIFFERENTIAL AND RUN TO MAX
DIFFERENTIAL OK BUT BOILER CONTINUES TO HEAT PAST 88°C
CHARACTERISTIC TEST FROM TEMPERATURE CH OPERATION DIFFERENTIAL AND RUN TO MAX
26/05/2021 10:53:55 2105_1_50_1 14/07/2021 11:24:18
08/06/2021 06:25:19
GAS VALVE RESISTANCE - SIT
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
GAS VALVE RESISTANCE - HONEYWELL
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
GAS VALVE RESISTANCE - HONEYWELL
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
FLOW STAT RESISTANCE
REMOVE THE CONNECTOR
BY-PASS (INTERNAL) OPENS CORRECTLY
ENSURE THERE IS NO FLOW AROUND THE HEATING SYSTEM
I.E. TURN OFF ALL RADIATORS
VOLTAGE DIVERTER MOTOR AT PCB
{GAINPCBACS}
DISC
WARMSTART RESISTANCE
REMOVE THE CONNECTOR FROM THE WARM STAT WHICH IS SITUATED ADJACENT TO THE PUMP
DIVERTER VALVE MOTOR OPERATION
REMOVE, BY UNSCREWING THE RETAINING RING,
THE DIVERTER VALVE MOTOR FROM THE DIVERTER VALVE
GAS VALVE MODULATION VOLTAGE (NO MODULATION)
{GAINPCBACS}
ON/OFF SWITCH IN THE ON POSITION
FLOW STAT RESISTANCE
REMOVE THE CONNECTOR
GAS VALVE VOLTAGE
{GAINPCBACS}
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
R203 RESISTANCE
{GAINPCBACS}
EXTERNAL CONTROLS (VOLTAGE OUT)
{GAINPCBACS}
EXTERNAL CONTROLS CALLING
EXTERNAL CONTROLS (VOLTAGE IN)
{GAINPCBACS}
DISCONNECT INTEGRAL CONTROLS
REMOVE THE INTEGRAL
VOLTAGE DIVERTER MOTOR AT PCB
{GAINPCBACS}
DISC
LOCKOUT RESET RETURN THERMISTOR
ENSURE NO DEMAND
RETURN SENSOR HARNESS RESISTANCE
DISCONNECT CONNECTOR X2 FROM THE PCB
RETURN STAT RESISTANCE
REMOVE THE CONNECTOR
LOCKOUT RESET FLOW THERMISTOR
ENSURE NO DEMAND
FLOW SENSOR HARNESS RESISTANCE
DISCONNECT CONNECTOR X2 FROM THE PCB
FLOW STAT RESISTANCE
REMOVE THE CONNECTOR
LOCKOUT RESET F 62
ENSURE NO DEMAND
AIR PRESSURE SWITCH (NORMALLY OPEN)
{GAINPCBACS}
APS TUBES CONDITION
LOCATE THE AIR PRESS
FAULT CODE RESET
ENSURE BOILER IS COOL
ENSURE NO DEMAND
FLOW STAT RESISTANCE
REMOVE THE CONNECTOR
RETURN STAT RESISTANCE
REMOVE THE CONNECTOR
TEMPERATURE CH OPERATION DIFFERENTIAL
ON/OFF SWITCH IN ON
OBSERVATION BOILER RESET F27
ENSURE NO DEMAND
ELECTRODE SPARKING (FAULT CODE)
REMOVE COMBUSTION CHAMBER DOOR
ON/OFF SWITCH IN ON POSITION
ELECTRODE/LEAD RESISTANCE
REMOVE BOTH SPARK LEADS FROM THE PCB
INSPECTION WIRING HARNESS
{GAINPCBACS}
OBSERVATION DISCONNECT X2
{GAINPCBACS}
REMOVE THE LEFT MOLEX CONNECTOR ON THE TOP LEFT OF THE PCB MARKED X2 AND MAKE SAFE
VOLTAGE MAIN PCB TO DISPLAY PCB
{GAINPCBACS}
DISCONNECT THE DISPLAY PCB FROM THE FRONT OF THE BOILER FASCIA
AIR PRESSURE SWITCH (AIR DETECT)
{GAINPCBACS}
PUMP VOLTAGE
ON/OFF SWITCH IN ON
GAS VALVE VOLTAGE
{GAINPCBACS}
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
R203 RESISTANCE
{GAINPCBACS}
GAS VALVE RESISTANCE - SIT
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
GAS VALVE RESISTANCE - SIT
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
RESISTANCE TRANSFORMER
DISCONNECT CONNECTOR X3 FROM THE PCB
RESISTANCE FAN
GAIN ACCESS TO THE FAN
DISCONNECT THE WIRES FROM THE FAN MOTOR AND EARTH POINTS
GAS VALVE RESISTANCE - SIT
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
MAINS POWER SUPPLY
{GAINPCBACS}
RESISTANCE FUSE MAINS
REMOVE THE FUSE FROM THE FUSED SPUR
TRANSFORMER (VOLTAGE IN)
{GAINPCBACS}
ON/OFF SWITCH IN ON POSITION
FLOW SENSOR HARNESS RESISTANCE
DISCONNECT CONNECTOR X2 FROM THE PCB
FLOW STAT RESISTANCE
REMOVE THE CONNECTOR
RETURN STAT RESISTANCE
REMOVE THE CONNECTOR
VOLTAGE PCB TO AQUA SENSOR (PERMANENT)
{GAINPCBACS}
INSPECTION IMPELLOR
DHW CIRCUIT DRAINED AND ISOLATED
INSPECTION PCB JUMPER
{GAINPCBACS}
FLOW STAT RESISTANCE
REMOVE THE CONNECTOR
DIODE GAS VALVE HARNESS
REMOVE THE GAS VALVE
GAS VALVE RESISTANCE - HONEYWELL
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
GAS VALVE RESISTANCE - HONEYWELL
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
OBSERVATION BURNER SHUT OFF
RUN HOT WATER TAP UNTIL WATER COOL THEN TURN TAP OFF
DHW TEMPERATURE SELECTOR TO MAX
VOLTAGE GAS VALVE AT DEMAND END
{GAINPCBACS}
RUN
GAS VALVE RESISTANCE - SIT
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
HEAT EXCHANGER FLUE WAYS
REMOVE THE COMBUSTION CHAMBER FRONT PANEL
FLAME SENSE ELECTRODE CONDITION AND POSITION
DISCONNECT THE LEAD FROM THE FLAME SENSE ELECTRODE
INSPECTION BURNER
REMOVE THE BURNER ASSEMBLY
INSPECTION BURNER MANIFOLD
REMOVE BURNER MANIFOLD
SPARK ELECTRODE GAP
REMOVE THE COMBUSTION CHAMBER FRONT PANEL.
HEAT EXCHANGER FLUE WAYS
REMOVE THE COMBUSTION CHAMBER FRONT PANEL
DIVERTER VALVE MOTOR OPERATION
REMOVE, BY UNSCREWING THE RETAINING RING,
THE DIVERTER VALVE MOTOR FROM THE DIVERTER VALVE
GAS VALVE MODULATION VOLTAGE (NO MODULATION)
{GAINPCBACS}
ON/OFF SWITCH IN THE ON POSITION
CH OPERATION
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
INSPECTION BURNER MANIFOLD
REMOVE BURNER MANIFOLD
DIVERTER VALVE OPERATION (CH)
ON/OFF SWITCH IN ON
BY-PASS (INTERNAL)
ENSURE RADIATORS ARE OPEN AND THAT WATER CAN CIRCULATE AROUND THE SYSTEM
BY-PASS (INTERNAL) OPENS CORRECTLY
ENSURE THERE IS NO FLOW AROUND THE HEATING SYSTEM
I.E. TURN OFF ALL RADIATORS
BOILER VERSION
LOCATION OF THE LOW WATER PRESSURE SWITCH IS JUST ABOVE THE PUMP, RIGHT-HAND SIDE OF THE BOILER
GAS INLET PRESSURE
ON/OFF SWITCH IN ON
GAS VALVE RESISTANCE - HONEYWELL
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
GAS VALVE VOLTAGE
{GAINPCBACS}
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
GAS VALVE RESISTANCE - SIT
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
GAS INLET PRESSURE
ON/OFF SWITCH IN ON
WATER PRESSURE SWITCH CONTINUITY
REMOVE THE COVER FRO
WATER PRESSURE SWITCH WIRING HARNESS RESISTANCE
REMOVE THE COVER FROM THE WATER PRESSURE SWITCH BY PULLING BACKWARDS ALONG THE WIRING
HEAT EXCHANGER FLUE WAYS
REMOVE THE COMBUSTION CHAMBER FRONT PANEL
VENTURI BLOCKED
DISCONNECT BOTH AIR
APS TUBES CONDITION
LOCATE THE AIR PRESS
PUMP VOLTAGE
ON/OFF SWITCH IN ON
FAN VOLTAGE
{GAINPCBACS}
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
GAS VALVE RESISTANCE - SIT
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE
OBSERVATION BURNER SHUT OFF
RUN HOT WATER TAP UNTIL WATER COOL THEN TURN TAP OFF
DHW TEMPERATURE SELECTOR TO MAX
VOLTAGE GAS VALVE AT DEMAND END
{GAINPCBACS}
RUN
VENTURI BLOCKED
DISCONNECT BOTH AIR
FLOW SENSOR HARNESS RESISTANCE
DISCONNECT CONNECTOR X2 FROM THE PCB
RETURN SENSOR HARNESS RESISTANCE
DISCONNECT CONNECTOR X2 FROM THE PCB
PUMP OVERRUN
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
TEMPERATURE DHW OPERATION DIFFERENTIAL
ON/OFF SWITCH IN ON
TEMPERATURE CH OPERATION DIFFERENTIAL AND RUN TO MAX
ON/OFF SWITCH IN ON
FLAME SENSE ELECTRODE CONDITION AND POSITION
DISCONNECT THE LEAD FROM THE FLAME SENSE ELECTRODE
SPARK ELECTRODE GAP
REMOVE THE COMBUSTION CHAMBER FRONT PANEL.
PUMP RUNS (CH DEMAND)
ON/OFF SWITCH IN ON POSITION
CH TEMP SELECTOR TO MAX
DHW TEMP SELECTOR TO MIN
APS TUBES CONDITION
LOCATE THE AIR PRESS
VENTURI BLOCKED
DISCONNECT BOTH AIR
APS HARNESS RESISTANCE
GAIN ACCESS TO PCB
USE INSULATION MAT AS REQUIRED
ELECTRODE/LEAD RESISTANCE
REMOVE BOTH SPARK LEADS FROM THE PCB
SPARK ELECTRODE GAP
REMOVE THE COMBUSTION CHAMBER FRONT PANEL.
GAS INLET PRESSURE
ON/OFF SWITCH IN ON
GAS VALVE RESISTANCE AND HARNESS
REMOVE CONNECTOR X14 FROM THE PCB
GAS INLET PRESSURE
ON/OFF SWITCH IN ON
RESISTANCE PUMP
DISCONNECT CONNECTOR X12 FROM THE PCB
RESISTANCE FAN AND HARNESS
DISCONNECT CONNECTOR X13 FROM THE PCB
GAS VALVE RESISTANCE AND HARNESS (SIT VALVE) - FUSE INV
REMOVE CONNECTOR X14 FROM THE PCB
WATER PRESSURE SWITCH CONTINUITY
REMOVE THE COVER FRO
BOILER VERSION
LOCATION OF THE LOW WATER PRESSURE SWITCH IS JUST ABOVE THE PUMP, RIGHT-HAND SIDE OF THE BOILER
FUSE T2 RESISTANCE
REMOVE BLACK FUSE HOLDER T2 FROM THE PCB
FUSE T1.25 RESISTANCE
REMOVE THE BROWN FUSE HOLDER T1.25 FROM THE PCB
TRANSFORMER (VOLTAGE OUT)
{GAINPCBACS}
ON/OFF SWITCH IN ON POSITION
CH DEMAND OFF
DHW DEMAND OFF
VOLTAGE MAIN PCB TO DISPLAY PCB
{GAINPCBACS}
DISCONNECT THE DISPLAY PCB FROM THE FRONT OF THE BOILER FASCIA
RETURN SENSOR HARNESS RESISTANCE
DISCONNECT CONNECTOR X2 FROM THE PCB
FLOW LIMITER
ISOLATE THE DHW SUPPLY AND REMOVE THE DHW INLET
DIODE GAS VALVE HARNESS
REMOVE THE GAS VALVE
PRESSURE BURNER MAXIMUM AND MINIMUM
DHW TEMPERATURE SELE
GAS INLET PRESSURE
ON/OFF SWITCH IN ON
GAS INLET PRESSURE
ON/OFF SWITCH IN ON
BY-PASS (INTERNAL)
ENSURE RADIATORS ARE OPEN AND THAT WATER CAN CIRCULATE AROUND THE SYSTEM
RESISTANCE APS WITH KIT
REMOVE APS FROM BOILER (LOCATED TOP RIGHT BEHIND COMBUSTION CHAMBER)
PCB VOLTS DHW DEMAND
{GAINPCBACS}
GAS VALVE MODULATION RESISTANCE
DISCONNECT THE MODULATION SOLENOID CONNECTOR FROM THE GAS VALVE
DHW FILTER
MAINS WATER OFF
<
GAS VALVE MODULATION RESISTANCE
DISCONNECT THE MODULATION SOLENOID CONNECTOR FROM THE GAS VALVE
GAS VALVE HARNESS RESISTANCE
REMOVE THE RED LEADS FROM THE MODULATION GAS VALVE
GAS VALVE MODULATION VOLTAGE
{GAINPCBACS}
ON/O
GAS VALVE HARNESS RESISTANCE
REMOVE THE RED LEADS FROM THE MODULATION GAS VALVE
GAS VALVE MODULATION VOLTAGE
{GAINPCBACS}
ON/O
GAS INLET PRESSURE
ON/OFF SWITCH IN ON
INSPECTION PCB JUMPER
{GAINPCBACS}
RESISTANCE GAS VALVE AND HARNESS HONEYWELL FUSE INV
{GAINPCBACS}
DISCONNECT CONNECTOR X14 FROM THE PCB
GAS VALVE RESISTANCE - HONEYWELL
DISCONNECT THE MAIN MULTI-PIN CONNECTOR FROM THE GAS VALVE