47-581-43 RAVENHEAT CSI 85 AAA 780 SERIES
GLOBAL PAGE
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
SOLID RED LOCKOUT LED
OUTSIDE MODEL
FLASHING RED LOCKOUT LED
OUTSIDE MODEL
FUSE INVESTIGATION DUMMY
OUTSIDE MODEL
OBSERVATION BOILER STANDBY
ENSURE NO DEMAND FOR CH OR DHW
OBSERVATION FAN RUNS
REMOVE OUTER COMBUSTION CHAMBER
OBSERVATION BURNER IGNITES AND ESTABLISHES
REFIT COMBUSTION CHAMBER IF IT WAS REMOVED ON PREVIOUS TEST
PRESSURE BURNER MAX AND MIN
ATTACH U-GAUGE TO GAS VALVE BURNER PRESSURE TEST POINT
OBSERVATION DHW MODULATION
ATTACH U-GAUGE TO GAS VALVE BURNER PRESSURE TEST POINT
OBSERVATION CH MODULATION
ATTACH U-GAUGE TO GAS VALVE BURNER PRESSURE TEST POINT
HOW TO SET MULTIMETER TO DIODE MODE
THE IMAGES BELOW SHO
FLASHING RED
POTENTIOMETER (DHW)
FLASHING RED
HEAT EXCHANGER - CONDENSING
SOLID RED
SENSOR - FLUE
OBSERVATION DHW FLOW RATE
DHW ISOLATION VALVE
OBSERVATION DHW FLOW RATE
WATER SUPPLY
OBSERVATION BOILER STANDBY
SWITCH (ON / OFF)
OBSERVATION BOILER STANDBY
MAINS FUSE
OBSERVATION BOILER STANDBY
FUSE 2A 20MM
FLASHING RED
GAS INLET PRESSURE
OBSERVATION BOILER STANDBY
FROST PROTECTION
OBSERVATION BOILER STANDBY
OPEN TAP OR LEAK
OBSERATION PUMP RUNS - PUMP
HARNESS
OBSERATION PUMP RUNS
FLOW SWITCH ASSEMBLY
OBSERATION PUMP RUNS
SENSOR - CH
FLASHING RED - OPEN CIRCUIT
THERMOSTAT (OVERHEAT)
OBSERATION PUMP RUNS
SENSOR (DHW)
FLASHING RED - STUCK IN FAULT
MAIN PCB
FLASHING RED - NO POWER TO PUMP
MAIN PCB
FLASHING RED - PUMP
HARNESS
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING FLASHING RED
THERMOSTAT (OVERHEAT)
OBSERVATION BURNER IGNITES AND ESTABLISHES - SPARKING NO IGNITION
GAS INLET PRESSURE
OBSERVATION BURNER IGNITES AND ESTABLISHES - SPARKING NO IGNITION - SOLENOID FAULTY
GAS VALVE - HONEYWELL W/O PILOT
OBSERVATION BURNER IGNITES AND ESTABLISHES - SPARKING NO IGNITION
ELECTRODE (SPARK)
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
GAS INLET PRESSURE
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
CABLES - SENSING AND SPARK
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
ELECTRODE (RECTIFICATION)
OPERATION DHW - DHW RUNS HOT COLD
PUMP - CIRCULATION
OPERATION DHW - DHW RUNS HOT COLD DHW SENSOR
SENSOR (DHW)
OPERATION DHW - DHW RUNS HOT COLD
HEAT EXCHANGER - CONDENSING
OPERATION DHW - DHW TOO HOT
KNOB (DHW)
OPERATION DHW - DHW TOO HOT DHW SENSOR
SENSOR (DHW)
OPERATION DHW - TOO COOL RADS HEAT
MAIN PCB
OPERATION DHW - DHW TOO COOL
KNOB (DHW)
OPERATION DHW - DHW TOO COOL
PUMP - CIRCULATION
OBSERVATION DHW - DHW TOO COOL
HEAT EXCHANGER - CONDENSING
FUSE INVESTIGATION - PUMP
HARNESS
FUSE INVESTIGATION - MODULATION SOLENOID
GAS VALVE - HONEYWELL W/O PILOT
INFORMATION CASE REMOVAL
Z REDIRECT
OPERATION DHW - DHW RUNS HOT COLD
SENSOR - CH
FUSE INVESTIGATION - MAIN SOLENOID
GAS VALVE - HONEYWELL W/O PILOT
OPERATION DHW - DHW TOO HOT
POTENTIOMETER (DHW)
OBSERVATION DHW MODULATION
KNOB (DHW)
OBSERVATION DHW MODULATION
POTENTIOMETER (DHW)
OBSERVATION DHW MODULATION
SENSOR (DHW)
OPERATION CH RADS DO NOT HEAT
SYSTEM PRESSURE
FLASHING RED - RUNNING SLOW
PUMP - CIRCULATION
OPERATION CH RADS DO NOT HEAT
CH ISOLATION VALVE
OPERATION CH RADS DO NOT HEAT
PUMP - CIRCULATION
OPERATION CH RADS DO NOT HEAT
MAIN PCB
OPERATION CH RADS DO NOT HEAT
HARNESS
OPERATION CH RADS DO NOT HEAT
DIVERTER VALVE CARTRIDGE
EXCESSIVE SYSTEM PRESSURE
EXPANSION VESSEL 6 LITRE
OPERATION CH - RADS COOL
KNOB (CH)
OPERATION CH - RADS COOL
SENSOR - CH
OPERATION CH - RADS COOL
POTENTIOMETER (CH)
FLASHING RED
SENSOR - CH
FLASHING RED
SENSOR (DHW)
OBSERVATION CH MODULATION
POTENTIOMETER (CH)
OBSERVATION CH MODULATION
SENSOR - CH
OBSERVATION CH MODULATION
KNOB (CH)
OBSERVATION PUMP OVERRUN
MAIN PCB
HOW TO SET MULTIMETER TO DIODE MODE
Z REDIRECT
OBSERVATION DHW FLOW RATE
FLOW SWITCH ASSEMBLY
OBSERVATION BOILER STANDBY SOLID RED
SENSOR - FLUE
OBSERVATION BOILER STANDBY - FAULTY LED
Z REDIRECT
OBSERVATION BOILER RESPONDS TO CH DEMAND
SWITCH (SUMMER / WINTER)
OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES
COVER - COMBUSTION CHAMBER
OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES
TRAY - CONDENSING
OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES
HEAT EXCHANGER
OBSERVATION BURNER IGNITES AND ESTABLISHES - BAFFLES
HEAT EXCHANGER - CONDENSING
FLASHING RED - MODUREG
GAS VALVE - HONEYWELL W/O PILOT
INFORMATION BOILER SETUP
Z REDIRECT
OBSERVATION BOILER STANDBY
FLOW SWITCH ASSEMBLY
PRESSURE BURNER MAX AND MIN
GAS INLET PRESSURE
PRESSURE BURNER MAX AND MIN - MODUREG
GAS VALVE - HONEYWELL W/O PILOT
PRESSURE BURNER MAX AND MIN
POTENTIOMETER (DHW)
OPERATION DHW - DHW COOL
POTENTIOMETER (DHW)
OPERATION DHW - DHW TOO COOL DHW SENSOR
SENSOR (DHW)
OPERATION DHW - DHW COOL
SENSOR - CH
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH - NOT CROSS LIGHTING
GAS INLET PRESSURE
TYPE OF DIAGNOSTIC PROCEDURE
Z REDIRECT
OBSERVATION BOILER STANDBY
POWER LED
OBSERVAITON BOILER STANDBY
ROOM STAT OR TIMER
OPERATION CH - RADS COOL
PCB POTENTIOMETER
OBSERVATION BOILER STANDBY
PCB JUMPER
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED - NO DC SUPPLY TO FAN BOARD
MAIN PCB
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED - NO VOLTAGE TO APS
PCB - FAN CONTROL
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED - NO IGNITION VOLTAGE
PCB - FAN CONTROL
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED
COVER - COMBUSTION CHAMBER
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED
TRAY - CONDENSING
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED
HEAT EXCHANGER - CONDENSING
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING FLASHING RED
CABLES - SENSING AND SPARK
OBSERVATION BOILER STANDBY SOLID RED LOCKOUT
SWITCH - PRESSURE - LOW WATER
SOLID RED
SWITCH - PRESSURE - LOW WATER
OBSERVATION FAN RUNS
SENSOR - CH
OBSERVATION FAN RUNS
SENSOR (DHW)
OBSERVATION FAN RUNS
POTENTIOMETER (DHW)
OBSERVATION FAN RUNS - FAN
HARNESS
OBSERVATION FAN RUNS - CYCLING
MAIN PCB
OBSERVATION FAN RUNS - CYCLING - DC
MAIN PCB
FLASHING RED
SYSTEM PRESSURE
FLASHING RED
GAUGE - WATER
FLASHING RED
HEAT EXCHANGER - DHW
FLASHING RED
HEAT EXCHANGER
FLASHING RED
NO FAULT - OVERHEAT INVESTIGATION
FLASHING RED - NOT SHUTTING DOWN
MAIN PCB
FLASHING RED - TRIPPING EARLY
THERMOSTAT (OVERHEAT)
SOLID RED
Z REDIRECT
SOLID RED
SYSTEM PRESSURE
SOLID RED
GAUGE - WATER
SOLID RED - FLUE SENSOR
MAIN PCB
SOLID RED - FLUE SENSOR
HARNESS
OBSERVATION DHW FLOW RATE
HEAT EXCHANGER - DHW
OBSERVATION BOILER STANDBY - MAINS FUSE
Z REDIRECT
OBSERVATION BOILER STANDBY - PCB FUSE
Z REDIRECT
OBSERATION PUMP RUNS
PUMP - CIRCULATION
OBSERATION PUMP RUNS
DETECTOR - FLOW
FLASHING RED - OVERHEAT STAT
HARNESS
FLASHING RED - NOT RUNNING
PUMP - CIRCULATION
OBSERVATION BURNER IGNITES AND ESTABLISHES - SPARKING NO IGNITION
GAS VALVE ADJUSTMENT
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH
GAS VALVE ADJUSTMENT
FUSE INVESTIGATION - FAN
HARNESS
OPERATION DHW - DHW RUNS HOT COLD
GAUGE - WATER
FUSE INVESTIGATION
NO FAULT FUSE INVESTIGATION
OPERATION DHW - DHW RUNS HOT / COLD
SYSTEM PRESSURE
OPERATION DHW - DHW RUNS HOT COLD
HEAT EXCHANGER - DHW
OPERATION DHW - DHW RUNS HOT COLD
HEAT EXCHANGER
OPERATION DHW - DHW TOO HOT
MAIN PCB
OPERATION DHW - TOO COOL RADS HEAT
DIVERTER VALVE CARTRIDGE
OPERATION DHW - TOO COOL RADS HEAT
SWITCH MOTOR - DIVERTER VALVE
OPERATION DHW - DHW TOO COOL
GAUGE - WATER
FUSE INVESTIGATION
PUMP - CIRCULATION
OPERATION DHW - DHW TOO COOL
SYSTEM PRESSURE
OPERATION DHW - DHW TOO COOL
HEAT EXCHANGER - DHW
OPERATION DHW - DHW TOO COOL
HEAT EXCHANGER
OPERATION DHW - DHW COOL
INJECTOR
OBSERVATION DHW MODULATION
MAIN PCB
OPERATION CH RADS DO NOT HEAT
SWITCH MOTOR - DIVERTER VALVE
EXCESSIVE SYSTEM PRESSURE
EXPANSION VESSEL PIPE
OBSERVATION CH MODULATION
MAIN PCB
OBSERVATION BOILER STANDBY SOLID RED
SYSTEM PRESSURE
OBSERVATION BOILER STANDBY SOLID RED
GAUGE - WATER
FLASHING RED - MIN WRONG
GAS VALVE ADJUSTMENT
FLASHING RED - MODUREG
HARNESS
FLASHING RED - MAX WRONG
GAS VALVE ADJUSTMENT
OBSERVATION BOILER STANDBY
DETECTOR - FLOW
PRESSURE BURNER MAX AND MIN - MIN WRONG
GAS VALVE ADJUSTMENT
PRESSURE BURNER MAX AND MIN - MAX WRONG
GAS VALVE ADJUSTMENT
OPERATION DHW - DHW TOO COOL
MAIN PCB
OBSERVATION BOILER RESPONDS TO CH DEMAND
TIMER - DIGITAL
OBSERVATION BURNER IGNITES AND ESTABLISHES - DOES NOT ESTABLISH - NOT CROSS LIGHTING
GAS VALVE ADJUSTMENT
OPERATION CH - RADS COOL
MAIN PCB
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED - LOW VOLTAGE TO FAN
PCB - FAN CONTROL
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED - NO REST VOLTAGE
SWITCH - AIR PRESSURE - MODULATING
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED
TUBE 0 5M NYLON - PRESSURE SWITCH
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING SOLID RED - NOT SENSING PRESSURE
SWITCH - AIR PRESSURE - MODULATING
OBSERVATION BURNER IGNITES AND ESTABLISHES - NO SPARKING FLASHING RED
ELECTRODE (SPARK)
OBSERVATION BOILER STANDBY
PCB - FAN CONTROL
OBSERVATION BOILER STANDBY - SOLID RED
SWITCH - AIR PRESSURE - MODULATING
OBSERVATION BOILER STANDBY - SOLID RED
TUBE 0 5M NYLON - PRESSURE SWITCH
SOLID RED - LOW PRESSURE
MAIN PCB
SOLID RED
PCB - FAN CONTROL
SOLID RED
SWITCH - AIR PRESSURE - MODULATING
SOLID RED
TUBE 0 5M NYLON - PRESSURE SWITCH
SOLID RED
VENTURI
OBSERVATION FAN RUNS
MAIN PCB
OBSERVATION FAN RUNS
PCB - FAN CONTROL
OBSERVATION FAN RUNS - CYCLING
PCB - FAN CONTROL
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM PRESSURE SYSTEM
PRESSURE ON GAUGE DOES NOT INCREASE WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM PRESSURE SYSTEM
BOILER FAILS TO SHUTDOWN OR MODULATE AS IT REACHES TEMPERATURE
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
OVERHEAT TRIPS DURING OPERATION
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
SOLID RED LOCKOUT REOCCURS AFTER APPROX 5 SECONDS
CHARACTERISTIC TEST FROM OBSERVATION WHEN DOES SOLID RED LOCKOUT REOCCUR
SOLID RED LOCKOUT REOCCURS AFTER APPROX 15 SECONDS
CHARACTERISTIC TEST FROM OBSERVATION WHEN DOES SOLID RED LOCKOUT REOCCUR
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM PRESSURE SYSTEM
PRESSURE ON GAUGE DOES NOT INCREASE WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM PRESSURE SYSTEM
POWER LED DOES NOT ILLUMINATE
CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY
RED FAULT LED ILLUMINATED (SOLID LOCKOUT)
CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY
BOILER ATTEMPTS TO FIRE WITH NO DEMAND
CHARACTERISTIC TEST FROM OBSERVATION BOILER STANDBY
NO SPARKING, LOCKOUT LED FLASHING RED
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES
NO SPARKING, LOCKOUT LED SOLID RED
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES
SPARKING PRESENT BUT BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES
BURNER IGNITES BUT DOES NOT ESTABLISH (SPARKING CONTINUES)
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES
BURNER IGNITES BUT BAFFLES OUT
CHARACTERISTIC TEST FROM OBSERVATION BURNER IGNITES AND ESTABLISHES
DHW COOL, RADIATORS REMAIN COLD
CHARACTERISTIC TEST FROM OPERATION DHW
DHW COOL, RADIATORS BEGIN TO HEAT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
DHW RUNS HOT / COLD
CHARACTERISTIC TEST FROM OPERATION DHW
SYSTEM PRESSURE READS CORRECTLY BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM PRESSURE SYSTEM
SYSTEM PRESSURE READS CORRECTLY BUT DOES NOT INCREASE
CHARACTERISTIC TEST FROM OBSERVATION RUN BOILER UP TO TEMPERATURE
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM PRESSURE SYSTEM
BOILER AND RADIATOR TEMPERATURE LOW
CHARACTERISTIC TEST FROM OPERATION CH
EXCESSIVE SYSTEM PRESSURE RISE
CHARACTERISTIC TEST FROM OPERATION CH
BOILER REACHES TEMPERATURE RADIATORS DO NOT HEAT
CHARACTERISTIC TEST FROM OPERATION CH
MAXIMUM PRESSURE OK BUT MINIMUM INCORRECT
CHARACTERISTIC TEST FROM PRESSURE BURNER MAX AND MIN
SYSTEM PRESSURE LOW
CHARACTERISTIC TEST FROM PRESSURE SYSTEM
PRESSURE ON GAUGE DOES NOT INCREASE WHEN WATER ADDED TO SYSTEM
CHARACTERISTIC TEST FROM PRESSURE SYSTEM
MAXIMUM PRESSURE WRONG
CHARACTERISTIC TEST FROM PRESSURE BURNER MAX AND MIN
MAXIMUM PRESSURE OK BUT MINIMUM INCORRECT
CHARACTERISTIC TEST FROM PRESSURE BURNER MAX AND MIN
MAXIMUM PRESSURE WRONG
CHARACTERISTIC TEST FROM PRESSURE BURNER MAX AND MIN
APS TUBE UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION APS TUBE AND VENTURI
VENTURI UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION APS TUBE AND VENTURI
APS TUBE UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION APS TUBE AND VENTURI
VENTURI UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION APS TUBE AND VENTURI
APS TUBE UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION APS TUBE AND VENTURI
VENTURI UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION APS TUBE AND VENTURI
FAN CYCLES ON AND OFF
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS
VOLTAGE PRESENT ON BOTH WIRES
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL CONTROLS (UNDER BOILER)
NO VOLTAGE ON EITHER WIRE
CHARACTERISTIC TEST FROM VOLTAGE EXTERNAL CONTROLS (UNDER BOILER)
21/03/2019 10:22:56 1902_1_50_1 01/04/2019 14:07:18
01/04/2019 10:35:33
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY RED ARROWS
INSPECTION CONDENSING HEAT EXCHANGER WATERWAYS
DRAIN BOILER PRIMARY CIRCUIT
OBSERVATION WHEN DOES SOLID RED LOCKOUT REOCCUR
ENSURE NO DEMANDS
RESISTANCE FLUE SENSOR
DISCONNECT PLUG FROM FLUE SENSOR
RESISTANCE MAINS FUSE
REMOVE THE FUSE FROM THE FUSED SPUR
RESISTANCE OVERHEAT STAT AND HARNESS
DISCONNECT M10 FROM THE PCB
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE OVERHEAT STAT
DISCONNECT LEADS FROM OVERHEAT STAT
RESISTANCE CH THERMISTOR
DISCONNECT WIRES FROM CH THERMISTOR
RESISTANCE DHW THERMISTOR
DISCONNECT PLUG FROM DHW THERMISTOR
VOLTAGE PUMP AT PCB
{GAINPCBACS}
RESISTANCE OVERHEAT STAT
DISCONNECT LEADS FROM OVERHEAT STAT
RESISTANCE PUMP AND HARNESS
DISCONNECT M4 FROM THE PCB
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS VALVE INLET TEST POINT
RESISTANCE GAS VALVE MAIN SOLENOID
DISCONNECT LEAD FROM GAS VALVE MAIN SOLENOID
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS VALVE INLET TEST POINT
RESISTANCE FAN
DISCONNECT LEADS FROM FAN
RESISTANCE SUMMER / WINTER SWITCH AND HARNESS
{GAINPCBACS}
SUMMER / WINTER SWITCH SET TO WINTER (PUSHED IN)
DISCONNECT M6 FROM THE PCB
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY RED ARROWS
INSPECTION CONDENSING HEAT EXCHANGER WATERWAYS
DRAIN BOILER PRIMARY CIRCUIT
RESISTANCE HARNESS PUMP
DISCONNECT PLUG FROM THE PUMP
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY RED ARROWS
INSPECTION CONDENSING HEAT EXCHANGER WATERWAYS
DRAIN BOILER PRIMARY CIRCUIT
RESISTANCE GAS VALVE MODUREG
DISCONNECT LEADS FROM GAS VALVE MODUREG
RESISTANCE GAS VALVE MAIN SOLENOID
DISCONNECT LEAD FROM GAS VALVE MAIN SOLENOID
RESISTANCE FLUE SENSOR
DISCONNECT PLUG FROM FLUE SENSOR
RESISTANCE SUMMER / WINTER SWITCH
SUMMER / WINTER SWITCH SET TO WINTER (PUSHED IN)
RESISTANCE GAS VALVE MODUREG
DISCONNECT LEADS FROM GAS VALVE MODUREG
RESISTANCE DHW POTENTIOMETER
DISCONNECT M11 FROM PCB
OBSERVATION DISCONNECT FLOW SWITCH
DISCONNECT ELECTRICA
INSPECTION FLOW SWITCH ASSEMBLY
DHW CIRCUIT ISOLATED AND DRAINED
UNCLIP SENSOR AND REMOVE FLOW SWITCH ASSEMBLY
RESISTANCE GAS VALVE MODUREG
DISCONNECT LEADS FROM GAS VALVE MODUREG
RESISTANCE DHW POTENTIOMETER
DISCONNECT M11 FROM PCB
RESISTANCE DHW POTENTIOMETER
DISCONNECT M11 FROM PCB
PRESSURE BURNER ON IGNITION
ATTACH U-GAUGE TO GAS VALVE BURNER PRESSURE TEST POINT
PRESSURE GAS INLET
ATTACH U-GAUGE TO GAS VALVE INLET TEST POINT
VOLTAGE TO FAN AT FAN BOARD (NO SPARKING)
{GAINPCBACS}
VOLTAGE PCB TO FAN BOARD - DC SUPPLY AT FAN BOARD
{GAINPCBACS}
VOLTAGE PCB TO FAN BOARD - DC SUPPLY AT PCB
{GAINPCBACS}
VOLTAGE APS (PERMANENT)
{GAINPCBACS}
RESISTANCE HARNESS M3
DISCONNECT M3 FROM THE PCB
RESISTANCE LOW WATER PRESSURE SWITCH
DISCONNECT LEAD FROM LOW WATER PRESSURE SWITCH
VOLTAGE APS (FAN SPEED AT REST)
{GAINPCBACS}
RESISTANCE LOW WATER PRESSURE SWITCH
DISCONNECT LEAD FROM LOW WATER PRESSURE SWITCH
VOLTAGE APS (FAN SPEED AT REST)
{GAINPCBACS}
VOLTAGE PCB TO FAN BOARD AT MAIN PCB
{GAINPCBACS}
RESISTANCE CH THERMISTOR
DISCONNECT WIRES FROM CH THERMISTOR
TEMPERATURE DIFFERENTIAL CH
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY RED ARROWS
OBSERVATION RUN BOILER UP TO TEMPERATURE
ATTACH A TEMPERATURE CLAMP/PROBE TO THE FLOW PIPE (RIGHT HAND SIDE, JUST ABOVE THE OVERHEAT STAT)
RESISTANCE FLUE SENSOR AND HARNESS
DISCONNECT M12 FROM THE PCB
INSPECTION FLOW SWITCH ASSEMBLY
DHW CIRCUIT ISOLATED AND DRAINED
UNCLIP SENSOR AND REMOVE FLOW SWITCH ASSEMBLY
VOLTAGE MAINS POWER IN
{GAINPCBACS}
RESISTANCE FUSE F1
REMOVE PCB FUSE FROM ITS HOLDER
RESISTANCE ON/OFF SWITCH
ON / OFF SWITCH SET TO ON (PUSHED IN)
OBSERVATION SET BOILER TO SUMMER
SET BOILER TO SUMMER MODE (BUTTON EXTENDED)
ENSURE NO DEMANDS
OBSERVATION ISOLATE DHW
TURN DHW ISOLATION VALVE OFF
RESISTANCE HARNESS PUMP
DISCONNECT PLUG FROM THE PUMP
RESISTANCE HARNESS DHW FLOW SWITCH
DISCONNECT CONNECTOR FROM FLOW SWITCH
INSPECTION FLOW SWITCH ASSEMBLY
DHW CIRCUIT ISOLATED AND DRAINED
UNCLIP SENSOR AND REMOVE FLOW SWITCH ASSEMBLY
RESISTANCE DHW THERMISTOR AND HARNESS
DISCONNECT M12 FROM THE PCB
RESISTANCE CH THERMISTOR AND HARNESS
DISCONNECT M12 FROM THE PCB
OBSERVATION BOILER RESET (OVERHEAT / FLASHING RED LOCKOUT)
ENSURE APPLIANCE IS COOL
RESISTANCE OVERHEAT STAT AND HARNESS
DISCONNECT M10 FROM THE PCB
PRESSURE BURNER ON IGNITION
ATTACH U-GAUGE TO GAS VALVE BURNER PRESSURE TEST POINT
PRESSURE BURNER ON IGNITION
ATTACH U-GAUGE TO GAS VALVE BURNER PRESSURE TEST POINT
RESISTANCE HARNESS PUMP
DISCONNECT PLUG FROM THE PUMP
RESISTANCE GAS VALVE MAIN SOLENOID AND HARNESS
DISCONNECT M10 FROM THE PCB
RESISTANCE FAN AND HARNESS
DISCONNECT CONNECTOR M4 FROM THE MAIN PCB
INSPECTION SPARK ELECTRODE
REMOVE SPARK ELECTRODE FROM BURNER (CENTRAL ELECTRODE)
INSPECTION INJECTOR
REMOVE INJECTOR BURNER RAIL
RESISTANCE RECTIFICATION LEAD
DISCONNECT LEAD FROM RECTIFICATION ELECTRODE
AND FROM "FLAME" ON THE PCB
RESISTANCE GAS VALVE MODUREG AND HARNESS
DISCONNECT M14 FROM THE PCB
INSPECTION RECTIFICATION ELECTRODE
REMOVE RECTIFICATION ELECTRODE FROM BURNER (LEFT ELECTRODE)
RESISTANCE GAS VALVE MAIN SOLENOID AND HARNESS
DISCONNECT M10 FROM THE PCB
OBSERVATION DIVERTER VALVE MOVEMENT (DHW)
UNCLIP DIVERTER MOTO
RESISTANCE DHW THERMISTOR
DISCONNECT PLUG FROM DHW THERMISTOR
RESISTANCE CH THERMISTOR
DISCONNECT WIRES FROM CH THERMISTOR
TEMPERATURE DIFFERENTIAL DHW
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY RED ARROWS
RESISTANCE DHW THERMISTOR
DISCONNECT PLUG FROM DHW THERMISTOR
RESISTANCE HARNESS DIVERTER VALVE
DISCONNECT PLUG FROM DIVERTER VALVE
TEMPERATURE DIFFERENTIAL DHW
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY RED ARROWS
PRESSURE BURNER MAXIMUM
ATTACH U-GAUGE TO GAS VALVE BURNER PRESSURE TEST POINT
RESISTANCE DHW POTENTIOMETER
DISCONNECT M11 FROM PCB
RESISTANCE DHW POTENTIOMETER
DISCONNECT M11 FROM PCB
RESISTANCE DHW THERMISTOR
DISCONNECT PLUG FROM DHW THERMISTOR
PRESSURE EXPANSION VESSEL
DRAIN BOILERS PRIMARY CIRCUIT
OBSERVATION DIVERTER VALVE MOVEMENT (CH)
UNCLIP DIVERTER MOTO
INSPECTION DIVERTER VALVE SPINDLE
REMOVE DIVERTER VALV
RESISTANCE HARNESS DIVERTER VALVE
DISCONNECT PLUG FROM DIVERTER VALVE
RESISTANCE DHW THERMISTOR
DISCONNECT PLUG FROM DHW THERMISTOR
RESISTANCE CH THERMISTOR
DISCONNECT WIRES FROM CH THERMISTOR
RESISTANCE CH THERMISTOR
DISCONNECT WIRES FROM CH THERMISTOR
RESISTANCE CH POTENTIOMETER
DISCONNECT M11 FROM PCB
RESISTANCE CH POTENTIOMETER
DISCONNECT M11 FROM PCB
RESISTANCE CH THERMISTOR
DISCONNECT WIRES FROM CH THERMISTOR
OBSERVATION WHEN DOES SOLID RED LOCKOUT REOCCUR (SELF CHECK)
ENSURE NO DEMANDS
PRESSURE BURNER MAX AND MIN
ATTACH U-GAUGE TO GAS VALVE BURNER PRESSURE TEST POINT
TEMPERATURE DIFFERENTIAL DHW
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES AS INDICATED BY RED ARROWS
RESISTANCE FLUE SENSOR AND HARNESS
DISCONNECT M12 FROM THE PCB
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
{GAINPCBACS}
DISCONNECT M12 FROM THE PCB
OBSERVATION DISCONNECT M3
DISCONNECT CONNECTOR MARKED M3 AT THE PCB AND MAKE SAFE
RESISTANCE GAS VALVE MODUREG AND HARNESS
DISCONNECT M14 FROM THE PCB
INSPECTION FAN
DISCONNECT LEADS FROM FAN
REMOVE TWO SCREWS HOLDING FAN, SLIDE FAN OUT
INSPECTION HEAT EXCHANGER FLUEWAYS
DISCONNECT LEADS FROM FAN
REMOVE TWO SCREWS HOLDING FAN, SLIDE FAN OUT
INSPECTION CONDENSING HEAT EXCHANGER FLUEWAYS
DISCONNECT LEADS FROM FAN
REMOVE TWO SCREWS HOLDING FAN, SLIDE FAN OUT
INSPECTION INJECTOR
REMOVE INJECTOR BURNER RAIL
INSPECTION BURNER
REMOVE INJECTOR BURNER RAIL
DISCONNECT SPARK AND RECTIFICATION LEADS AT ELECTRODES
OBSERVATION DISCONNECT M6
{GAINPCBACS}
DISCONNECT CONNECTOR M6 FROM THE PCB
PRESSURE GAS INLET (OPERATION)
ATTACH U-GAUGE TO GAS VALVE INLET TEST POINT
PRESSURE GAS INLET (OPERATION)
ATTACH U-GAUGE TO GAS VALVE INLET TEST POINT
RESISTANCE GAS VALVE MODUREG AND HARNESS
DISCONNECT M14 FROM THE PCB
RESISTANCE DHW THERMISTOR
DISCONNECT PLUG FROM DHW THERMISTOR
RESISTANCE CH THERMISTOR
DISCONNECT WIRES FROM CH THERMISTOR
RESISTANCE HARNESS TIMER
DISCONNECT WIRES FROM CONNECTIONS
MARKED 3 AND 5 ON THE INTERNAL TIMER
INSPECTION INJECTOR
REMOVE INJECTOR BURNER RAIL
DIODE TEST POWER LED
SET MULTIMETER TO DI
ADJUSTMENT POTENTIOMETER P1
ATTACH U-GAUGE TO BURNER PRESSURE TEST POINT
OBSERVATION SPARKING AT PCB
DISCONNECT LEAD FROM SPARK GENERATOR AND POSITION ABOVE THE GENERATOR AS SHOWN
VOLTAGE APS (FAN SPEED AT REST)
{GAINPCBACS}
OBSERVATION SPARKING WITH KIT
GAIN ACCESS INNER CO
RESISTANCE HARNESS APS
DISCONNECT PLUG FROM AIR PRESSURE SENSOR
INSPECTION FAN
DISCONNECT LEADS FROM FAN
REMOVE TWO SCREWS HOLDING FAN, SLIDE FAN OUT
INSPECTION HEAT EXCHANGER FLUEWAYS
DISCONNECT LEADS FROM FAN
REMOVE TWO SCREWS HOLDING FAN, SLIDE FAN OUT
INSPECTION CONDENSING HEAT EXCHANGER FLUEWAYS
DISCONNECT LEADS FROM FAN
REMOVE TWO SCREWS HOLDING FAN, SLIDE FAN OUT
RESISTANCE SPARK ELECTRODE LEAD
DISCONNECT LEAD FROM SPARK ELECTRODE
AND FROM SPARK GENERATOR ON THE PCB
RESISTANCE LOW WATER PRESSURE SWITCH AND HARNESS
{GAINPCBACS}
DISCONNECT M12 FROM THE PCB
OBSERVATION DISCONNECT M3
DISCONNECT CONNECTOR MARKED M3 AT THE PCB AND MAKE SAFE
VOLTAGE PCB TO FAN BOARD AT MAIN PCB (CYCLING)
{GAINPCBACS}
VOLTAGE FAN AT FAN
GAIN ACCESS TO FAN
RESISTANCE DHW THERMISTOR
DISCONNECT PLUG FROM DHW THERMISTOR
RESISTANCE DHW POTENTIOMETER
DISCONNECT M11 FROM PCB