Set Appliance State:

Mains Power Off
Set Multimeter to DC Volts Set meter to measure DC Volts
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Test 1: - Ensure Hot Water Taps OFF
Measure the voltage between the black wire marked "D" on M6 at the main PCB to pin 9 (purple) at the fan control board.
Expected voltage approximately 5V DC.
Test 2: - Turn Hot Water Tap ON
Measure the voltage between the black wire marked "D" on M6 at the main PCB to pin 9 (purple) at the fan control board.
Voltage should now be approximately 0V DC.