Set Appliance State:

Mains Power Off
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the voltage between the red wire marked "E" and the yellow wire marked "C" at M10 on the PCB.
At the sparking stage of the ignition sequence approximately 215V DC should be measured.
Note:
Boiler will attempt ignition 3 times before going to lockout.
Reset by turning power off then back on as necessary.