Set Appliance State:
Turn Hot Water Tap On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
With a flow rate of 9.9 litres per minute does the boiler produce a temperature rise of 40°C and is operation satisfactory?
Note.
1. To investigate a poor water flow rate from the tap CLICK HERE
2. Flow rates lower / higher than the flow rate specified will result in a higher / lower temperature rise, and boiler will modulate if temperature is close to maximum (65°C). This must be taken into account when selecting an outcome of the test.
Note.
1. To investigate a poor water flow rate from the tap CLICK HERE
2. Flow rates lower / higher than the flow rate specified will result in a higher / lower temperature rise, and boiler will modulate if temperature is close to maximum (65°C). This must be taken into account when selecting an outcome of the test.