Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
ELM LE-BLANC WINDSOR GVM 4.20
G.C. NUMBER 47 241 0
CH SYSTEM PRESSURE RISE
ROTARY SWITCH IN CH
CENTRAL HEATING
ROTARY SWITCH IN CH
HOT WATER
ROTARY SWITCH IN DHW
CH DEMAND (SATISFIED)
ROTARY SWITCH IN CH AND DHW POSITION
CH OPERATIVE THERMOSTAT ADJUSTED TO MAXIMUM
CH HIGH BURNER
ROTARY SWITCH IN CH
CH HIGH FAN
ROTARY SWITCH IN CH
CH PUMP FLOW VALVE OPERATION
ROTARY SWITCH IN CH AND DHW POSITION
KEEP BOILER CASE SWITCH DEPRESSED
DHW BURNER MODULATES
ROTARY SWITCH IN DHW
DHW HIGH BURNER
ROTARY SWITCH IN DHW
DHW LOW BURNER
ROTARY SWITCH IN DHW POSITION
DHW CONTROL ADJUSTED TO MAXIMUM
DEPRESS BOILER CASE SWITCH
DHW DEMAND
ROTARY SWITCH IN DHW POSITION
KEEP BOILER CASE SWITCH DEPRESSED
GAS VALVE FLAME FAILURE DEVICE
ROTARY SWITCH IN DHW POSITION
PILOT ESTABLISHED
ROTARY SWITCH IN DHW POSITION
PILOT IGNITES
ROTARY SWITCH IN DHW POSITION
PILOT SPARKING
ROTARY SWITCH IN DHW POSITION
KEEP BOILER CASE SWITCH DEPRESSED
HIGH FAN (IGNITION DEMAND)
ROTARY SWITCH DHW POSITION
KEEP BOILER CASE SWITCH DEPRESSED
SLOW FAN OPERATION
ROTARY SWITCH IN DHW POSITION
KEEP BOILER CASE SWITCH DEPRESSED
DHW FLOW RATE
{ISOLATEMAINSPOWER}
SYSTEM CHECKS
{ISOLATEMAINSPOWER}
ELM LE-BLANC WINDSOR GVM 4.20
G.C. NUMBER 47 241 0
DHW LOW BURNER
LIGHTER SWITCH
DHW LOW BURNER
GAS VALVE SOLENOID
DHW HIGH BURNER
GAS VALVE SOLENOID
DHW HIGH BURNER
PCB
DHW HIGH BURNER
MODULATION BOX
DHW HIGH BURNER
MODULATING GAS VALVE
DHW BURNER MODULATES
DHW ADJUSTMENT CAM
DHW BURNER MODULATES
MODULATION BOX
DHW BURNER MODULATES
MODULATING GAS VALVE
CH PUMP FLOW VALVE OPERATION
ROTARY SWITCH
CH PUMP FLOW VALVE OPERATION
ROOM THERMOSTAT
CH PUMP FLOW VALVE OPERATION
PUMP FLOW VALVE SPINDLE
CH PUMP FLOW VALVE OPERATION
PUMP FLOW VALVE DIAPHRAGM
CH HIGH FAN
CH CONTROL THERMOSTAT
CH HIGH BURNER
PUMP FLOW SWITCH
CH DEMAND (SATISFIED)
CH CONTROL THERMOSTAT
PILOT SPARKING
LIGHTER SWITCH
PILOT SPARKING
SPARK CONNECTOR
DHW LOW BURNER
TRANSFORMER
DHW FLOW RATE
DHW FLOW VALVE PISTON
DHW DEMAND
DHW FLOW VALVE PISTON
CH SYSTEM PRESSURE RISE
EXPANSION VESSEL
CENTRAL HEATING
CH BYPASS ADJUSTMENT
ELECTRICAL CHECKS
ELECTRICAL CHECKS
SYSTEM CHECKS
SYSTEM CHECKS
DHW FLOW RATE
DHW INLET FILTER
SLOW FAN OPERATION
BOILER CASE SWITCH
SLOW FAN OPERATION
MAINS POWER
SLOW FAN OPERATION
3 AMP FUSE
HIGH FAN (IGNITION DEMAND)
LIGHTER SWITCH
PILOT SPARKING
SPARK ELECTRODE
PILOT SPARKING
TRANSFORMER
PILOT SPARKING
SPARK ELECTRODE LEAD
PILOT IGNITES
PILOT
PILOT ESTABLISHED
OVERHEAT THERMOSTAT
PILOT ESTABLISHED
THERMOCOUPLE
GAS VALVE FLAME FAILURE DEVICE
PUSH BUTTON GAS VALVE
DHW DEMAND
DHW FLOW VALVE SPINDLE
DHW DEMAND
DHW FLOW VALVE DIAPHRAGM
DHW DEMAND
MODULATION BOX
DHW LOW BURNER
AIR PRESSURE SWITCH TUBES
DHW LOW BURNER
FLUE
DHW LOW BURNER
0.25 AMP FUSE
DHW LOW BURNER
CH LIMIT THERMOSTAT
DHW LOW BURNER
DHW LIMIT THERMOSTAT
DHW LOW BURNER
DHW FLOW SWITCH MICROSWITCHES
DHW LOW BURNER
PCB
DHW LOW BURNER
BURNER INJECTOR
DHW LOW BURNER
GAS VALVE
DHW HIGH BURNER
GAS VALVE
DHW BURNER MODULATES
DHW PHIAL/THERMOSTAT
CH PUMP FLOW VALVE OPERATION
DHW FLOW SWITCH MICROSWITCHES
CH PUMP FLOW VALVE OPERATION
CH NON RETURN VALVE
HOT WATER
HEAT EXCHANGER
PILOT SPARKING
SPARK GENERATOR
HOT WATER
CH NON RETURN VALVE
CENTRAL HEATING
HEAT EXCHANGER
DHW FLOW RATE
HEAT EXCHANGER
SLOW FAN OPERATION
ROTARY SWITCH
PILOT IGNITES
GAS CONTROL VALVE
PILOT ESTABLISHED
MAGNETIC HEAD
DHW DEMAND
DHW FLOW SWITCH MICROSWITCHES
DHW LOW BURNER
AIR PRESSURE SWITCH
DHW NOT HEATING, RADIATORS COLD
CHARACTERISTIC TEST FROM HOT WATER
DHW NOT HEATING, RADIATORS WARM
CHARACTERISTIC TEST FROM HOT WATER
HEAT EXCHANGER NOISY OPERATION
CHARACTERISTIC TEST FROM CENTRAL HEATING
HEAT EXCHANGER QUIET OPERATION
CHARACTERISTIC TEST FROM CENTRAL HEATING
26/08/2014 14:47:20 1408_1_50_1 27/08/2014 14:54:59
27/08/2014 09:41:11
GAS VALVE SOLENOID RESISTANCE
{ISOLATEMAINSPOWER}
GAS VALVE SOLENOID RESISTANCE
{ISOLATEMAINSPOWER}
DHW TEMPERATURE ADJUSTMENT CAM
{ISOLATEMAINSPOWER}
CH PUMP VOLTAGE
ROTARY SWITCH IN CH
TIMER OUTPUT VOLTAGE
ROTARY SWITCH IN CH AND DHW POSITION
KEEP CASE SWITCH DEPRESSED
CH THERMOSTAT OUTPUT VOLTAGE
{ISOLATEMAINSPOWER}<
DHW INLET FILTER
{ISOLATEMAINSPOWER}
TURN OFF MAINS WATER SUPPLY
BOILER CASE SWITCH OUTPUT VOLTAGE
{ISOLATEMAINSPOWER}<
BOILER CASE SWITCH RESISTANCE
{ISOLATEMAINSPOWER}
LIGHTER SWITCH CONTACTS 1 AND 3 RESISTANCE
{ISOLATEMAINSPOWER}
SPARK ELECTRODE
{ISOLATEMAINSPOWER}
PILOT INJECTOR
{ISOLATEMAINSPOWER}
OVERHEAT THERMOSTAT RESISTANCE
{ISOLATEMAINSPOWER}
DHW FLOW VALVE PISTON
{ISOLATEMAINSPOWER}
TURN OFF MAINS WATER SUPPLY
LOW BURNER GAS VALVE VOLTAGE (DHW DEMAND)
ROTARY SWITCH IN DHW POSITION
AIR PRESSURE SWITCH CONTINUITY (DHW DEMAND)
{ISOLATEMAINSPOWER}
ROTARY SWITCH IN DHW POSITION
KEEP BOILER CASE SWITCH DEPRESSED
AIR PRESSURE SWITCH TUBES
{ISOLATEMAINSPOWER}
LIGHTER SWITCH RESISTANCE (NO IGNITION DEMAND)
{ISOLATEMAINSPOWER}
HIGH BURNER GAS VALVE VOLTAGE (DHW DEMAND)
ROTARY SWITCH IN CH AND DHW POSITION
MODULATION BOX
{ISOLATEMAINSPOWER}
MODULATING GAS VALVE TEST
DHW THERMOSTAT SET T
MODULATION BOX
{ISOLATEMAINSPOWER}
MODULATING GAS VALVE TEST
DHW THERMOSTAT SET T
CH PUMP RUNS
ROTARY SWITCH IN CH AND DHW POSITION
KEEP BOILER CASE SWITCH DEPRESSED
ROOM THERMOSTAT OUTPUT VOLTAGE
KEEP BOILER CASE SWITCH DEPRESSED
PUMP FLOW VALVE SPINDLE
{ISOLATEMAINSPOWER}
BOILER DRAINED AND DISCHARGED
PUMP FLOW VALVE DIAPHRAGM
{ISOLATEMAINSPOWER}
BOILER DRAINED AND DISCHARGED
LIGHTER SWITCH CONTACTS 2 AND 4 RESISTANCE
{ISOLATEMAINSPOWER}
INTERMEDIATE SPARK CONNECTOR
{ISOLATEMAINSPOWER}
CH BYPASS ADJUSTMENT
{ISOLATEMAINSPOWER}
DHW FLOW VALVE PISTON
{ISOLATEMAINSPOWER}
TURN OFF MAINS WATER SUPPLY
FUSE 3 AMP RESISTANCE
{ISOLATEMAINSPOWER}
MAINS POWER SUPPLY
ROTARY SWITCH IN OFF POSITION
SLOW FAN VOLTAGE
ROTARY SWITCH IN DHW POSITION
KEEP BOILER CASE SWITCH DEPRESSED
TRANSFORMER PRIMARY COIL RESISTANCE
{ISOLATEMAINSPOWER}
SPARK ELECTRODE LEAD
{ISOLATEMAINSPOWER}
THERMOCOUPLE MILLIVOLTAGE
ROTARY SWITCH IN DHW POSITION
KEEP GAS VALVE CONTROL KNOB DEPRESSED
DHW FLOW VALVE SPINDLE
{ISOLATEMAINSPOWER}
WATER OFF
APPLIANCE DISCHARGED AND DRAINED
DHW FLOW VALVE DIAPHRAGM
{ISOLATEMAINSPOWER}
WATER OFF
APPLIANCE DISCHARGED AND DRAINED
MODULATION BOX
{ISOLATEMAINSPOWER}
BURNER GAS PRESSURE (DHW DEMAND)
ROTARY SWITCH IN DHW
FUSE 0.25 AMP RESISTANCE
{ISOLATEMAINSPOWER}
CH LIMIT THERMOSTAT RESISTANCE
{ISOLATEMAINSPOWER}
ENSURE THE BOILER IS NOT IN AN OVERHEATED CONDITION
DHW LIMIT THERMOSTAT RESISTANCE
{ISOLATEMAINSPOWER}
ENSURE THE BOILER IS NOT IN AN OVERHEATED CONDITION
TRANSFORMER SECONDARY WINDING RESISTANCE
{ISOLATEMAINSPOWER}
DHW FLOW SWITCH CONTACTS B RESISTANCE (DHW DEMAND)
{ISOLATEMAINSPOWER}
System Information
- Total Tests: 143
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control