Set Appliance State:
Mains Power Off
CH Demand
Rotary Switch in CH and DHW position
CH Operative Thermostat adjusted to Maximum
Keep Boiler Case Switch depressed
CH Operative Thermostat adjusted to Maximum
Keep Boiler Case Switch depressed
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage across connector 4 (Brown wire) and connector 3 (Blue wire) on connector plug A, located on the base of the control box.

Isolate as per TOPs P4
and refit as necessary