Welcome to the XSol Diagnostic System
This system provides interactive diagnostic tests with proper sequence navigation based on the decoded .seq file logic.
EUROCOMBI STYX SX 20 MFFICE
WARNING - IMPORTA
EXPANSION VESSEL
MODE SELECTOR SWITCH TO CH POSITION
CENTRAL HEATING OPERATION
SELECTOR SWITCH IN CH/DHW WINTER POSITION
HEATING THERMOSTAT SET TO MAXIMUM
HOT WATER
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
CH MODULATION
SELECTOR SWITCH IN CH/DHW WINTER POSITION
HEATING THERMOSTAT SET TO MAXIMUM
CH BURNER IGNITES
SELECTOR SWITCH IN CH/DHW WINTER POSITION
HEATING THERMOSTAT SET TO MAXIMUM
CH FAN RUNS
SELECTOR SWITCH IN CH/DHW WINTER POSITION
HEATING THERMOSTAT SET TO MAXIMUM
CH MAIN FLOW SWITCH OPERATION
SELECTOR SWITCH IN CH/DHW WINTER POSITION
HEATING THERMOSTAT SET TO MAXIMUM
DHW MODULATION
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
DHW FLAME SENSE
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
DHW BURNER IGNITES
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
DHW FAN RUNS
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
DHW MAIN FLOW SWITCH OPERATION
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
EUROCOMBI STYX SX 20 MFFICE
G.C. NUMBER 47 11
DHW MODULATION
MODULATION SOLENOID
CH MAIN FLOW SWITCH OPERATION
SUMMER/WINTER SWITCH
CH FAN RUNS
CH THERMOSTAT
CH BURNER IGNITES
CH THERMOSTAT
CH MODULATION
DHW MICROSWITCHES
DHW BURNER IGNITES
SPARK ELECTRODE LEADS
MAINS SWITCH
ON/OFF SWITCH
MAINS SWITCH LED ONLY
ON/OFF SWITCH
EXPANSION VESSEL
EXPANSION VESSEL
ELECTRICAL CHECK
ELECTRICAL CHECK
WEAK OR SLOW
WATER PUMP
COMPENSATION TUBE
COMPENSATION TUBE
DHW DEMAND
DHW FLOW ADJUSTMENT
DHW MAIN FLOW SWITCH OPERATION
FUSE 2A LIVE
DHW MAIN FLOW SWITCH OPERATION
OVERHEAT THERMOSTAT
DHW MAIN FLOW SWITCH OPERATION
SYSTEM PRESSURE
DHW MAIN FLOW SWITCH OPERATION
DHW MICROSWITCHES
DHW MAIN FLOW SWITCH OPERATION
FUSE 2A NEUTRAL
DHW FAN RUNS
DHW MICROSWITCHES
DHW FAN RUNS
LIMIT THERMOSTAT
DHW FAN RUNS
AIR PRESSURE SWITCH
DHW FAN RUNS
LOCKOUT RESET SWITCH
NO SPARKING OBSERVED
AIR PRESSURE SWITCH TUBE
NO SPARKING OBSERVED
FLUE
NO SPARKING OBSERVED
FLUE VENTURI
SPARKING OBSERVED
AIR PRESSURE SWITCH TUBE
SPARKING OBSERVED
FLUE
SPARKING OBSERVED
FLUE VENTURI
SPARKING OBSERVED
PRINTED CIRCUIT BOARD - PCB
DHW BURNER IGNITES
GAS VALVE OPERATOR SOLENOIDS
DHW BURNER IGNITES
GAS VALVE ASSEMBLY
DHW FLAME SENSE
SENSE ELECTRODE
DHW MODULATION
PRINTED CIRCUIT BOARD - PCB
DHW MODULATION
DHW THERMOSTAT
DHW MODULATION
GAS VALVE ASSEMBLY
CH MAIN FLOW SWITCH OPERATION
ROOM THERMOSTAT/LINK
CH MAIN FLOW SWITCH OPERATION
PROGRAMMER
CH MODULATION
CH THERMOSTAT
HOT WATER
SECONDARY HEAT EXCHANGER
HOT WATER
DIVERTER VALVE
CENTRAL HEATING OPERATION
SECONDARY HEAT EXCHANGER
HOT WATER
PRIMARY HEAT EXCHANGER
DHW BURNER INGNITES
SPARK ELECTRODES
IGNITION VOLTAGE (FAIL)
PRINTED CIRCUIT BOARD - PCB
SYSTEM CHECKS
SYSTEM CHECKS
DHW MAIN FLOW SWITCH
SLUDGE
DHW MAIN FLOW SWITCH OPERATION
MAIN FLOW SWITCH
DHW MAIN FLOW SWITCH
DIAPHRAGM
DHW MAIN FLOW SWTICH OPERATION
SERVICE KIT
DHW DEMAND
DIVERTER VALVE DIAPHRAGM/SPINDLE
SECONDARY HEAT EXCHANGER - SCALED
SECONDARY HEAT EXCHANGER - SCALED
DHW MAIN FLOW SWITCH OPERATION
PUMP PRESSURE SWITCH
DHW MAIN FLOW SWITCH OPERATION
WATER PUMP
DHW FAN RUNS
MAIN FLOW MICROSWITCH
DHW FAN RUNS
FAN
DHW FAN RUNS
PRINTED CIRCUIT BOARD - PCB
NO SPARKING OBSERVED
AIR PRESSURE SWITCH
SPARKING OBSERVED
AIR PRESSURE SWITCH
DHW BURNER IGNITES
BURNER INJECTORS
DHW FLAME SENSE
PRINTED CIRCUIT BOARD - PCB
DHW MODULATION
DHW MICROSWITCHES
DHW NOISY OPERATION
CHARACTERISTIC TEST FROM HOT WATER
DHW QUIET OPERATION, COLD RADIATORS
CHARACTERISTIC TEST FROM HOT WATER
DHW QUIET OPERATION, WARM RADIATORS
CHARACTERISTIC TEST FROM HOT WATER
CH NOISY OPERATION
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
CH NOISY OPERATION
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
CH QUIET OPERATION
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
FLOW SWITCH BODY DAMAGED
CHARACTERISTIC TEST FROM INSPECTION FLOW DIAPHRAGM
DIAPHRAGM SPLIT OR DAMAGED
CHARACTERISTIC TEST FROM INSPECTION FLOW DIAPHRAGM
SPRING OR SPINDLE DAMAGED
CHARACTERISTIC TEST FROM INSPECTION FLOW DIAPHRAGM
NO SPARKING OBSERVED
CHARACTERISTIC TEST FROM DHW BURNER IGNITES
SPARKING OBSERVED
CHARACTERISTIC TEST FROM DHW BURNER IGNITES
18/10/2017 08:57:14 1712_1_50_1 31/01/2018 09:56:55
08/01/2018 14:06:55
PROGRAMMER
SELECTOR SWITCH IN CH/DHW WINTER POSITION
HEATING THERMOSTAT SET TO MAXIMUM
SELECTOR SWITCH
SELECTOR SWITCH IN CH/DHW WINTER POSITION
HEATING THERMOSTAT SET TO MAXIMUM
CH THERMOSTAT VOLTAGE IN
SELECTOR SWITCH IN CH/DHW WINTER POSITION
HEATING THERMOSTAT SET TO MAXIMUM
SPARK ELECTRODE LEAD RESISTANCE
DISCONNECT BOTH ELECTRODE LEADS FROM THE PCB AND SPARK ELECTRODES
MAINS POWER SUPPLY
{GAINPCBACS}
DHW FLOW SETTING
TURN ON HW TAP FULLY
DEMAND VOLTAGE
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
FUSE F1 2A (L)
REMOVE THE FUSE F1 FROM PCB
DHW PUMP VOLTAGE
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
MAIN FLOW MICRO-SWITCH
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
DHW START VOLTAGE
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
SENSE VOLTAGE
SELECTOR SWITCH IN D
DHW THERMOSTAT VOLTAGE IN
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
24V DC SUPPLY
SELECTOR SWITCH IN D
MODULATION COIL RESISTANCE
REMOVE BOTH WIRES FROM MODULATION COIL
CENTRAL HEATING OPERATION
SELECTOR SWITCH IN CH/DHW WINTER POSITION
HEATING THERMOSTAT SET TO MAXIMUM
SPARK ELECTRODE LEADS
SELECTOR SWITCH IN D
RESISTANCE ON OFF SWITCH
DISCONNECT THE LEADS FROM THE ON/OFF SWITCH, NOTING THEIR CONNECTIONS
ON/OFF SWITCH ON
INFORMATION MAINS POWER LED
TESTS INDICATE THE L
INSPECTION FLOW DIAPHRAGM
BOILER PRIMARY CIRCUIT DRAINED
REMOVE THE FLOW SWITCH ASSEMBLY FROM THE BOILER
DHW PUMP RUNS
REMOVE PUMP SCREW
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
FUSE F2 2A (N)
REMOVE FUSE F2 FROM PCB
AIR PRESSURE SWITCH: NO AIR RESISTANCE
REMOVE THE THREE WIRES FROM THE AIR PRESSURE SWITCH NOTING THEIR POSITIONS.
LIMIT THERMOSTAT
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
FAN RELAY
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
AIR PRESSURE TEST: AIR DETECT
SELECTOR SWITCH IN D
AIR PRESSURE TEST: AIR DETECT
SELECTOR SWITCH IN D
IGNITION VOLTAGE
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
GV OPERATOR SOLENOID RESISTANCE
REMOVE THE TWO RED WIRES FROM EV1 AND EV2 AND THE BLUE WIRE ON COM
BURNER PRESSURE
ATTACH U GAUGE TO BU
DHW THERMOSTAT VOLTAGE OUT
SELECTOR SWITCH IN DHW SUMMER POSITION
HOT WATER THERMOSTAT SET TO MAXIMUM
System Information
- Total Tests: 136
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control