Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Continuity Set meter to measure Continuity
Turn Hot Water Tap On
Selector Switch in DHW Summer position
Hot Water Thermostat set to Maximum
Remove all three wires from the Air Pressure Switch and make safe
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Using crocodile clips connect meter to COM and NO terminals of Air Pressure Switch.
When Fan starts can a continuous tone be heard from the meter?
Replace all three wires back on Air Pressure Switch as follows:
COM - Red/Black
NC - Brown
NO - White