BAXI MAIN ECO COMBI
WARNING - IMPORTA
POWER UP SELF CHECK
ENSURE NO DEMANDS
OBSERVATION FAN RUNS, BURNER IGNITES AND ESTABLISHES
ENSURE APPLIANCE IS COOL
FAULT CODE - SENSORS
NOT USED
FAULT CODE - MISCELLANEOUS
NOT USED
FAULT CODE - PARAMETER FAULT
NOT USED
FAULT CODE FAN FAULT
NOT USED
TYPE OF DIAGNOSTIC PROCEDURE
PLEASE SELECT FROM O
STATUS CODE - SHUTDOWN INPUT
NOT USED
STATUS CODE - COMMUNICATION FAULT
NOT USED
STATUS CODE - MISCELLANEOUS
NOT USED
& FUSE PCB FURTHER INVESTIGATION
NOT USED
ERROR CODE / STATUS CODE - OVERHEAT / TEMPERATURE PROTECTION
OK TO BE BLANK
PRESSURE GAS INLET
SLIGHTLY DISENGAGE T
HOW TO SET APPLIANCE TO FULL AND PART LOAD
SETTING THE APPLI
DHW FLOW SENSOR ERROR CODE
NOT USED
POOR FLOW RATE
DHW ISOLATION VALVE
POOR FLOW RATE
MAINS WATER SUPPLY
POOR FLOW RATE
CARTRIDGE RESTRICTOR
INCORRECT INLET PRESSURE
GAS INLET PRESSURE
EXCESSIVE PRESSURE RISE
EXPANSION VESSEL
STATUS CODE
Z REDIRECTION
FAULT CODES
Z REDIRECTION
APPLIANCE FIRES WITH NO DEMAND
KIT - SENSOR
PUMP DOES NOT RUN
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
APPLIANCE FIRES WITH NO DEMAND 1
KIT - SENSOR
APPLIANCE FIRES WITH NO DEMAND
PLUMBING ISSUE
FAN RUNS
KIT - SENSOR
DHW RUNS HOT THEN COLD
SYSTEM PRESSURE
DHW RUNS HOT THEN COLD
KIT - SENSOR
DHW RUNS HOT THEN COLD 1
KIT - SENSOR
DHW RUNS HOT THEN COLD
PUMP C/W SEAL
POOR HW COOL RADS
SYSTEM PRESSURE
POOR HW COOL RADS
KIT - SENSOR
POOR HW COOL RADS 1
KIT - SENSOR
FAILED GAS RATE
TRAP - CONDENSATE C/W SEAL
FAILED GAS RATE
AIR INTAKE
DHW TOO HOT
KIT - SENSOR
DHW TOO HOT 1
KIT - SENSOR
NO POWER TO DIVERTER MOTOR DHW
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BOILER UP TO TEMP RADS COLD
ISOLATION VALVES
NO POWER TO DIVERTER MOTOR
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
POOR HW COOL RADS
PUMP C/W SEAL
FAN DOES NOT RUN
SET - CABLE
BURNER IGNITION
TRAP - CONDENSATE C/W SEAL
BURNER IGNITION
GAS INLET PRESSURE
BOILER NOISY
GAS INLET PRESSURE
FAN DOES NOT RUN
KIT - SENSOR
FAN RUNS 2
KIT - SENSOR
LEDS DO NOT ILLUMINATE
MAINS FUSE
LEDS DO NOT ILLUMINATE
FUSE F1
FAULT CODE OVERHEAT 4
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAULT CODE OVERHEAT 8
KIT - SENSOR
FAULT CODE OVERHEAT
SYSTEM PRESSURE
OVERHEAT FAULT CODE
ISOLATION VALVES
OVERHEAT 1
KIT - SENSOR
OVERHEAT 2
KIT - SENSOR
NO PUMP OVERRUN
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FUSE INVESTIGATION 1
3-WAY VALVE C/W ACTUATOR
FUSE INVESTIGATION
3-WAY VALVE C/W ACTUATOR
FUSE INVESTIGATION
PUMP C/W SEAL
PUMP OVERRUN
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FULL AND PART LOAD GUIDANCE
Z REDIRECTION
FAILED COMBUSTION TEST
COMBUSTION SEALS
FAILED COMBUSTION TEST
AIR INTAKE
FAULT CODE PARAMETER
SET - CABLE
SET UP AND DESCRIPTION OF KEYS PAGE
Z REDIRECTION
NOT OPENING TO RADS
3-WAY VALVE C/W ACTUATOR
CH OPERATION INFORMATION
Z REDIRECTION
CH DOES NOT RESPOND 2
240V EXTERNAL CONTROL WIRING
CH DOES NOT RESPOND 1
240V EXTERNAL CONTROL WIRING
APPLIANCE FIRES WITH NO DEMAND
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BOILER SYS COOL
KIT - SENSOR
BOILER SYS COOL 2
KIT - SENSOR
BOILER SYS COOL
CONTROLLER - USER INTERACTION
CASE OFF
Z REDIRECTION
FAILED GAS RATE
BURNER MESH C/W GASKET
PARAMETER FAULT CODE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
PARAMETER ERROR CODE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
MISC ERROR CODE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FUSE INVESTIGATION GAS VALVE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FUSE INVESTIGATION FAN
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAN FAULT
ERROR CODE RESET
FAN ERROR CODE
FAN ELECTRICAL CONNECTIONS
CH NOT RECOGNISED 2
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
CH DOES NOT RESPOND
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
CH DOES NOT RESPOND 1
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
CH NOT RECOGNISED 1
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BURNER IGNITION
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
AIR INTAKE
AIR INTAKE
BURNER IGNITION 2
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BURNER IGNITION
FLUE
BURNER IGNITION
SET - ELECTRODES C/W SCREW & GASKET
BURNER IGNITION 2
BURNER MESH C/W GASKET
BURNER DOES NOT IGNITE AND EST
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BURNER DOES NOT IGNITE & EST
AIR INTAKE
BURNER DOES NOT IGNITE & EST 2
SET - ELECTRODES C/W SCREW & GASKET
BURNER DOES NOT IGNITE & EST
BURNER MESH C/W GASKET
POOR HW RADS COOL
EXTERNAL MIXING
PUMP RUNS CONTINUOUSLY
KIT - SENSOR
PUMP RUNS CONTINUOUSLY 1
KIT - SENSOR
PUMP RUNS CONTINUOUSLY
HMI CABLE
LEDS NOT ILLUMINATED
HMI CABLE
PWR UP SELF TEST
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BOILER NOISEY
AIR INTAKE
BOILER NOISY
FLUE
FAN DOES NOT RUN
HMI CABLE
FAN RUNS 2
CONTROLLER - USER INTERACTION
PUMP DOES NOT RUN
HMI CABLE
NO CH
HMI CABLE
NO CH 1
HMI CABLE
CH DOES NOT RESPOND 2
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
CH NOT RECOGNISED
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
CH DOES NOT RESPOND
240V EXTERNAL CONTROL WIRING
NO CH 2
HMI CABLE
COMM FAULT
WIRING HARNESS CONNECTIONS / WATER INGRESS
COMM FAULT
HMI CABLE
MISC FAULT CODE
WIRING HARNESS CONNECTIONS / WATER INGRESS
BOILER NOISY
COMBUSTION SEALS
BOILER NOISY
TRAP - CONDENSATE C/W SEAL
BOILER NOISY
BURNER MESH C/W GASKET
GAS VALVE FAULT 3
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAILED COMBUSTION TEST
BURNER MESH C/W GASKET
FAILED COMBUSTION TEST
TRAP - CONDENSATE C/W SEAL
COMBUSTION PERFORMANCE ANALYSIS
COMBUSTION VALUES CORRECTLY ADJUSTED
POOR HW RADS COOL
FILTER
DHW RUNS HOT THEN COLD
FILTER
OVERHEAT
HEAT ENGINE
OVERHEAT
FILTER
DHW FLOWS SENSOR ERROR CODE
SET - CABLE
FAULT CODE 2
KIT - SENSOR
FAULT CODE
KIT - SENSOR
FAULT CODE SENSORS
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
SENSOR ERROR CODE
SET - CABLE
NO SUPPLY VOLTAGE TO FLOW SENSOR
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
POOR HW
CONTROLLER - USER INTERACTION
POOR HW
HMI CABLE
INFORMATION RESETTING APPLIANCE
Z REDIRECTION
CHIMNEY SWEEP ILLUMINATED SOLID
BUTTONS STUCK IN
DIAGNOSTIC PROCEDURE
Z REDIRECTION
STATUS CODE SHUTDWN 2
CONTROLLER - USER INTERACTION
STATUS CODE MISC
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
LIMPET TEST
PUMP C/W SEAL
FAULT CODE OVERHEAT
PUMP C/W SEAL
POOR FLOW RATE
HEAT EXCHANGER - PLATE C/W SEALS
BLOCKED OR RESTRICTED
PIPE ASSEMBLY - EXPANSION VESSEL
STATUS CODE 2
Z REDIRECTION
FAULT CODES 1
Z REDIRECTION
APPLIANCE FIRES WITH NO DEMAND
FROST PROTECTION
PUMP DOES NOT RUN
PUMP C/W SEAL
DHW RUNS HOT THEN COLD
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
DHW RUNS HOT THEN COLD
HEAT ENGINE
POOR HW RADS COOL
HEAT ENGINE
DHW TOO HOT
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAILED GAS RATE
INTERFACE - FLUE C/W SEAL
FAILED GAS RATE
INTERFACE - SUMP
POOR HW RADS HEATING UP
3-WAY VALVE C/W ACTUATOR
POOR HW RADS HEAT UP
3-WAY VALVE C/W ACTUATOR
BOILER UP TO TEMP RADS COLD
3-WAY VALVE C/W ACTUATOR
FAN DOES NOT RUN
SENSOR - FLOW - DHW
BOILER NOISY
INTERFACE - FLUE C/W SEAL
BOILER NOISY
INTERFACE - SUMP
FUSE FURTHER INVESTIGATION MAINS
Z REDIRECTION
FUSE FURTHER INVESTIGATION
Z REDIRECTION
FAULT CODE OVERHEAT 6
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAULT CODE OVERHEAT
SET - CABLE
OVERHEAT 1
SET - CABLE
OVERHEAT 2
SET - CABLE
PWR UP SELF TEST
COMBUSTION CONTROL UNIT - FUSE INVESTIGATION
FAILED COMBUSTION TEST
INTERFACE - FLUE C/W SEAL
FAILED COMBUSTION TEST
INTERFACE - SUMP
FAN DOES NOT RUN
FAN ELECTRICAL CONNECTIONS
PARAMETER FAULT
ERROR CODE RESET
APPLIANCE FIRES WITH NO DEMAND
SENSOR - FLOW - DHW
BOILER SYS COOL
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAILED COMBUSTION TEST
HEAT ENGINE FLUEWAYS
FAN FAULT CODE 3
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAN DOES NOT RUN
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAN SEIZED
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
INCORRECT FAN RESISTANCES
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
GAS VALVE FAULT 2
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BEARING PLATE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAN FAULT CODE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
MISCELLANEOUS ERROR CODE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAN FAULT CODE 2
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
FAN ERROR CODE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
NO HEATING
CONTROLLER - USER INTERACTION
NO HTG
CONTROLLER - USER INTERACTION
FAILED GAS RATE
HEAT ENGINE FLUEWAYS
FAN BEARING PLATE FAILURE 1
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
CH DOES NOT RESPOND
EBUS CONTROLS
CH DOES NOT RESPOND 1
EBUS CONTROLS
BURNER IGNITION
INTERFACE - FLUE C/W SEAL
BURNER IGNITION
INTERFACE - SUMP
BURNER IGNITION
HEAT ENGINE FLUEWAYS
BEARING PLATE FAILURE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
GAS VALVE FAULT
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BURNER DOES NOT IGNITE & EST
SET - ELECTRODES C/W SCREW & GASKET
BURNER DOES NOT IGNITE & EST 2
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BURNER DOES NOT IGNITE & EST
INTERFACE - FLUE C/W SEAL
BURNER DOES NOT IGNITE & EST
INTERFACE - SUMP
BURNER DOES NOT IGNITE & EST
HEAT ENGINE FLUEWAYS
FAN BEARING PLATE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
GAS VALVE FAULT 1
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
POOR HW RADS COOL
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
PUMP RUNS CONTINUOUSLY
FROST PROTECTION
PUMP RUNS CONTINUOUSLY
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
LEDS DO NOT ILLUMINATE
CONTROLLER - USER INTERACTION
FAN RUNS
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
CH DOES NOT RESPOND 2
EBUS CONTROLS
CH DOES NOT RESPOND
CONTROLLER - USER INTERACTION
NORMAL OPERATION
OVERHEAT
OVERHEAT FAULT CODE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
OVERHEAT FAULT CODE
KIT - SENSOR
STATUS CODE COMMS
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
BOILER NOISY
HEAT ENGINE FLUEWAYS
FAN BEARING PLATE FAILURE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
GAS VALVE FAULT 4
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
CONTINUE TESTING
Z REDIRECTION
POOR HW RADS COOL
HEAT EXCHANGER - PLATE C/W SEALS
DHW RUNS HOT THEN COLD
HEAT EXCHANGER - PLATE C/W SEALS
OVERHEAT
HEAT EXCHANGER - PLATE C/W SEALS
SHORTED
SENSOR - FLOW - DHW
DHW FLOW SENSOR ERROR CODE
COMBUSTION CONTROL UNIT INC PARAMETER UNIT
SENSOR ERROR CODE
SENSOR - FLOW - DHW
FAULT CODE
SET - CABLE
FAULT CODE 2
SET - CABLE
FAULT CODE SENSOR
ERROR CODE RESET
FAN NOT RUNNING
SENSOR - FLOW - DHW
CHIMNEY ILLUMINATED SOLID
CONTROLLER - USER INTERACTION
FAULT CODE MISCELLANEOUS
ERROR CODE RESET
STATUS CODE SHUT DWN
ERROR CODE RESET
STATUS CODE SHUTDWN
CONTROLLER - USER INTERACTION
STATUS CODE SHUTDWN
BL TERMINALS - LINK
STATUS CODE COMS
ERROR CODE RESET
STATUS CODE MISC
ERROR CODE RESET
FAULT CODE OVERHEAT 3
PUMP C/W SEAL
SYSTEM PRESSURE RISE EXCESSIVE
CHARACTERISTIC TEST FROM CH OPERATION
DHW RUNS HOT THEN COLD
CHARACTERISTIC TEST FROM OPERATION DHW
TEMPERATURE RISE UNSATISFACTORY, RADIATORS REMAINS COOL
CHARACTERISTIC TEST FROM OPERATION DHW
TEMPERATURE RISE UNSATISFACTORY, RADIATORS HEAT WITH NO CH DEMAND
CHARACTERISTIC TEST FROM OPERATION DHW
DHW TOO HOT
CHARACTERISTIC TEST FROM OPERATION DHW
PUMP RUNS CONTINUOUSLY
CHARACTERISTIC TEST FROM POWER UP SELF TEST
APPLIANCE FIRES WITH NO DEMAND
CHARACTERISTIC TEST FROM POWER UP SELF TEST
PUMP DOES NOT RUN
CHARACTERISTIC TEST FROM POWER UP SELF TEST
DIFFERENTIAL EXCESSIVE
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
APPLIANCE DOES NOT RESPOND TO A CH DEMAND
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
DIFFERENTIAL EXCESSIVE
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
APPLIANCE DOES NOT RESPOND TO A HEATING DEMAND
CHARACTERISTIC TEST FROM TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
FAN RUNS, BURNER IGNITES BUT IS BAFFLING AND/OR NOISY
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS, BURNER IGNITES AND ESTABLISHES
FAN RUNS, BURNER DOES NOT IGNITE AND ESTABLISH
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS, BURNER IGNITES AND ESTABLISHES
SUMP RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
LEDS DO NOT ILLUMINATE
CHARACTERISTIC TEST FROM POWER UP SELF TEST
SUMP RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
POOR ELECTRICAL CONNECTION BETWEEN FAN MOTOR AND PCB
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION & RESISTANCE
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN BEARING PLATE FAILURE
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN RUNS
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS - FAULT CODE
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS, BURNER IGNITES AND ESTABLISHES
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN BEARING PLATE FAILURE
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
24 VOLT EXTERNAL CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF EXTERNAL CONTROLS ARE FITTED
EBUS EXTERNAL CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF EXTERNAL CONTROLS ARE FITTED
24 VOLT EXTERNAL CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF EXTERNAL CONTROLS ARE FITTED
EBUS EXTERNAL CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF EXTERNAL CONTROLS ARE FITTED
SUMP RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN BEARING PLATE FAILURE
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
SUMP RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN BEARING PLATE FAILURE
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
24 VOLT EXTERNAL CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF EXTERNAL CONTROLS ARE FITTED
EBUS EXTERNAL CONTROLS FITTED
CHARACTERISTIC TEST FROM OBSERVATION WHICH TYPE OF EXTERNAL CONTROLS ARE FITTED
APPLIANCE CONTINUES TO HEAT BEYOND 75 DEG
CHARACTERISTIC TEST FROM OBSERVATION DOES OVERHEAT OCCUR AT MAX TEMPERATURE
APPLIANCE OVERHEATS BEFORE 75 DEG IS REACHED
CHARACTERISTIC TEST FROM OBSERVATION DOES OVERHEAT OCCUR AT MAX TEMPERATURE
HEAT EXCHANGER FLUEWAYS RESTRICTED AND/OR BLOCKED
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
FAN BEARING PLATE FAILURE
CHARACTERISTIC TEST FROM INSPECTION HEAT EXCHANGER FLUEWAYS
CHIMNEY SWEEP LED ILLUMINATED (SOLID RED OR GREEN)
CHARACTERISTIC TEST FROM POWER UP SELF TEST
FAN PULSES
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS, BURNER IGNITES AND ESTABLISHES
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM OBSERVATION FAN RUNS, BURNER IGNITES AND ESTABLISHES
FAN SEIZED AND/OR ROTATION RESTRICTED
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION & RESISTANCE
FAN RESISTANCE NOT AS EXPECTED
CHARACTERISTIC TEST FROM OBSERVATION FAN ROTATION & RESISTANCE
APPLIANCE AND SYSTEM TEMPERATURE LOW
CHARACTERISTIC TEST FROM CH OPERATION
APPLIANCE UP TO TEMPERATURE, RADIATORS DO NOT HEAT SUFFICIENTLY
CHARACTERISTIC TEST FROM CH OPERATION
NO CONNECTIONS PRESENT @ BL TERMINALS
CHARACTERISTIC TEST FROM INSPECTION BL TERMINALS - USER INTERFACE
EXTERNAL WIRING CONNECTIONS PRESENT @ BL TERMINALS
CHARACTERISTIC TEST FROM INSPECTION BL TERMINALS - USER INTERFACE
ERROR / STATUS CODE (CHIMNEY SWEEP AND / OR RESET LED FLASHING RED OR GREEN)
CHARACTERISTIC TEST FROM POWER UP SELF TEST
02/03/2020 12:04:35 2002_1_50_1 12/03/2020 14:01:13
05/03/2020 12:47:39
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
VOLTAGE FLOW SENSOR - DEMAND
{GAINPCBACS}
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
THE TEMPERATURE CLAM
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
THE TEMPERATURE CLAM
VOLTAGE DIVERTER MOTOR AT PCB - DHW
{GAINPCBACS}
VOLTAGE DIVERTER MOTOR AT PCB - CH
{GAINPCBACS}
CH TEMPERATURE CONTROL SET TO MAX
RESISTANCE MAINS SUPPLY FUSE
REMOVE THE FUSE FROM THE FUSED SPUR
RESISTANCE SAFETY CIRCUIT AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE STAT OVERHEAT
GAIN ACCESS TO OVERHEAT STAT & DISCONNECT LEADS TO STAT
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
INSPECTION DIVERTER VALVE - FUSE INVESTIGATION
REMOVE ELECTRICAL CO
VOLTAGE RECTIFICATION AT PCB
{GAINPCBACS}
DISCONNECT SPARK ELECTRODE AT SPARK GENERATOR
DISCONNECT SPARK ELECTRODE LEAD FROM SPARK GENERATOR
INSPECTION AIR INTAKE MANIFOLD
REMOVE THE AIR INTAKE MANIFOLD
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE HMI CABLE
DISCONNECT HMI CABLE FROM CONTROLLER INTERFACE PCB AND THE MAIN PCB
TEMPERATURE DIFFERENTIAL PRIMARY HEAT EXCHANGER
THE TEMPERATURE CLAM
DISCONNECT DHW FLOW SENSOR - ERROR CODE
REMOVE ELECTRICAL CONNECTOR FROM THE DHW FLOW SENSOR AND MAKE SAFE
RESISTANCE DHW FLOW SENSOR HARNESS
REMOVE THE AIR INTAKE
REMOVE THE CONNECTOR FROM THE DHW FLOW SENSOR
DISCONNECT DHW FLOW SENSOR - ERROR CODE
REMOVE ELECTRICAL CONNECTOR FROM THE DHW FLOW SENSOR AND MAKE SAFE
RESISTANCE DHW FLOW SENSOR HARNESS
REMOVE THE AIR INTAKE
REMOVE THE CONNECTOR FROM THE DHW FLOW SENSOR
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
VOLTAGE FLOW SENSOR - SUPPLY - FLOW SENSOR DISCONNECTED
REMOVE ELECTRICAL CONNECTOR FROM THE DHW FLOW SENSOR AND MAKE SAFE
INSPECTION BL TERMINALS @ USER INTERFACE
GAIN ACCESS TO THE USER CONTROL INTERFACE PCB
INSPECTION WIRING HARNESS CONNECTIONS
GAIN ACCESS TO PCB
RESET APPLIANCE - OVERHEAT / TEMPERATURE PROTECTION
ENSURE APPLIANCE IS COOL
VOLTAGE PUMP AT PCB
{GAINPCBACS}
INSPECTION DHW CARTRIDGE RESTRICTOR
ISOLATE THE COLD WAT
PRESSURE EXPANSION VESSEL
APPLIANCE PRIMARY CIRCUIT DRAINED AND DISCHARGED
OBSERVATION DIVERTER VALVE MOTOR OPERATION - DHW
RELEASE THE SECURING
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
TEMPERATURE FLOW - FROST PROTECTION
ATTACH A TEMPERATURE CLAMP TO THE FLOW PIPE
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
VOLTAGE PUMP AT PCB
{GAINPCBACS}
OBSERVATION ISOLATE COLD MAINS SUPPLY
ISOLATE THE COLD MAINS SUPPLY
DISCONNECT DHW FLOW SENSOR
REMOVE ELECTRICAL CONNECTOR FROM THE DHW FLOW SENSOR AND MAKE SAFE
RESISTANCE DHW FLOW SENSOR HARNESS
REMOVE THE AIR INTAKE
REMOVE THE CONNECTOR FROM THE DHW FLOW SENSOR
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE POTENTIOMETER - DHW TEMPERATURE
DISCONNECT HMI CABLE
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER
ATTACH A TEMPERATURE
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER
ATTACH A TEMPERATURE
INSPECTION AIR INTAKE MANIFOLD
REMOVE THE AIR INTAKE MANIFOLD
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE THE COMBUSTION CONTROL UNIT AND GAIN
ACCESS TO THE HEAT EXCHANGER FLUEWAYS
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE POTENTIOMETER - DHW TEMPERATURE
DISCONNECT HMI CABLE
PRESSURE GAS INLET
SLIGHTLY DISENGAGE T
PRESSURE GAS INLET
SLIGHTLY DISENGAGE T
INSPECTION AIR INTAKE MANIFOLD
REMOVE THE AIR INTAKE MANIFOLD
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE THE COMBUSTION CONTROL UNIT AND GAIN
ACCESS TO THE HEAT EXCHANGER FLUEWAYS
RESISTANCE STAT OVERHEAT
GAIN ACCESS TO OVERHEAT STAT & DISCONNECT LEADS TO STAT
VOLTAGE MAINS AT PCB
{GAINPCBACS}
RESISTANCE FUSE PCB
REMOVE FUSE FROM THE PCB
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE DIVERTER MOTOR AND HARNESS - FUSE INVESTIGATION
REMOVE CONNECTOR X3 FROM THE PCB
RESISTANCE PUMP - FUSE INVESTIGATION
REMOVE PUMP COVER AND DISCONNECT ELECTRICAL CONNECTIONS
RESISTANCE FAN ASSEMBLY
GAIN ACCESS TO PCB
REMOVE FAN DRIVER PCB FROM THE FAN ASSEMBLY
RESISTANCE GAS VALVE - FUSE FURTHER INVESTIGATION
REMOVE ELECTRICAL CONNECTOR FROM THE GAS VALVE
INSPECTION AIR INTAKE MANIFOLD
REMOVE THE AIR INTAKE MANIFOLD
RESISTANCE HARNESS PARAMETER UNIT
REMOVE AIR INTAKE
REMOVE ELECTRICAL CONNECTOR TO PARAMETER UNIT
INSPECTION DIVERTER VALVE BODY
RELEASE THE SECURING
OBSERVATION WHICH TYPE OF EXTERNAL CONTROLS ARE FITTED
GAIN ACCESS TO CONTROLLER INTERFACE PCB
OBSERVATION IS WIRING CORRECT / LINK PRESENT AT 'OT' TERMINALS
GAIN ACCESS TO CONTROLLER INTERFACE PCB
VOLTAGE AT 'ENABLE' TERMINALS
{GAINPCBACS}
CH TEMPERATURE CONTROL SET TO MAX
OBSERVATION WHICH TYPE OF EXTERNAL CONTROLS ARE FITTED
GAIN ACCESS TO CONTROLLER INTERFACE PCB
OBSERVATION IS WIRING CORRECT / LINK PRESENT AT 'OT' TERMINALS
GAIN ACCESS TO CONTROLLER INTERFACE PCB
VOLTAGE AT 'ENABLE' TERMINALS
{GAINPCBACS}
CH TEMPERATURE CONTROL SET TO MAX
RESISTANCE HMI CABLE
DISCONNECT HMI CABLE FROM CONTROLLER INTERFACE PCB AND THE MAIN PCB
RESISTANCE THERMISTOR FLOW
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE FLOW THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE POTENTIOMETER - CH TEMPERATURE
DISCONNECT HMI CABLE
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE THE COMBUSTION CONTROL UNIT AND GAIN
ACCESS TO THE HEAT EXCHANGER FLUEWAYS
OBSERVATION ELECTRICAL CONNECTIONS BETWEEN FAN MOTOR AND PCB
GAIN ACCESS TO PCB
REMOVE FAN DRIVER PCB FROM THE FAN ASSEMBLY
DISCONNECT EBUS CONTROLS
DISCONNECT EBUS WIRING AND MAKE SAFE
BYPASS EXTERNAL CONTROLS 24V
DISCONNECT 24V EXTER
DISCONNECT EBUS CONTROLS
DISCONNECT EBUS WIRING AND MAKE SAFE
BYPASS EXTERNAL CONTROLS 24V
DISCONNECT 24V EXTER
INSPECTION AIR INTAKE MANIFOLD
REMOVE THE AIR INTAKE MANIFOLD
OBSERVATION SPARK GENERATOR
GAIN ACCESS TO THE PCB
REMOVE SPARK IGNITION LEAD FROM THE SPARK GENERATOR AND MAKE SAFE
INSPECTION ELECTRODE IGNITION
REMOVE SPARK ELECTRODE ASSEMBLY FROM THE APPLIANCE
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE THE COMBUSTION CONTROL UNIT AND GAIN
ACCESS TO THE HEAT EXCHANGER FLUEWAYS
VOLTAGE RECTIFICATION AT PCB - IGNITION
{GAINPCBACS}
INSPECTION ELECTRODE IGNITION
REMOVE SPARK ELECTRODE ASSEMBLY FROM THE APPLIANCE
INSPECTION HEAT EXCHANGER FLUEWAYS
REMOVE THE COMBUSTION CONTROL UNIT AND GAIN
ACCESS TO THE HEAT EXCHANGER FLUEWAYS
TEMPERATURE FLOW
ATTACH A TEMPERATURE CLAMP TO THE FLOW PIPE
RESISTANCE THERMISTOR RETURN
REMOVE THE AIR INTAKE AND FLUE INTERFACE
REMOVE RETURN THERMISTOR ELECTRICAL CONNECTOR
RESISTANCE HMI CABLE
DISCONNECT HMI CABLE FROM CONTROLLER INTERFACE PCB AND THE MAIN PCB
OBSERVATION DIVERTER MOTOR SPINDLE DURING PUMP PURGE
RELEASE THE SECURING
RESISTANCE HMI CABLE
DISCONNECT HMI CABLE FROM CONTROLLER INTERFACE PCB AND THE MAIN PCB
RESISTANCE HMI CABLE
DISCONNECT HMI CABLE FROM CONTROLLER INTERFACE PCB AND THE MAIN PCB
RESISTANCE HMI CABLE
DISCONNECT HMI CABLE FROM CONTROLLER INTERFACE PCB AND THE MAIN PCB
RESISTANCE HMI CABLE
DISCONNECT HMI CABLE FROM CONTROLLER INTERFACE PCB AND THE MAIN PCB
OBSERVATION WHICH TYPE OF EXTERNAL CONTROLS ARE FITTED
GAIN ACCESS TO CONTROLLER INTERFACE PCB
OBSERVATION IS WIRING CORRECT / LINK PRESENT AT 'OT' TERMINALS
GAIN ACCESS TO CONTROLLER INTERFACE PCB
BYPASS EXTERNAL CONTROLS 24V
DISCONNECT 24V EXTER
DISCONNECT EBUS CONTROLS
DISCONNECT EBUS WIRING AND MAKE SAFE
VOLTAGE AT 'ENABLE' TERMINALS
{GAINPCBACS}
CH TEMPERATURE CONTROL SET TO MAX
RESISTANCE HMI CABLE
DISCONNECT HMI CABLE FROM CONTROLLER INTERFACE PCB AND THE MAIN PCB
OBSERVATION CAN COMBUSTION VALUES BE ADJUSTED
CONNECT FGA TO THE COMBUSTION TEST POINT
COMBUSTION VALUES CORRECTLY ADJUSTED
THE COMBUSTION READI
INSPECTION FILTER
APPLIANCE DRAINED AN
INSPECTION FILTER
APPLIANCE DRAINED AN
INSPECTION FILTER
APPLIANCE DRAINED AN
RESISTANCE THERMISTOR FLOW AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE THERMISTOR RETURN AND HARNESS
REMOVE CONNECTOR X5 FROM THE PCB
RESISTANCE HMI CABLE
DISCONNECT HMI CABLE FROM CONTROLLER INTERFACE PCB AND THE MAIN PCB
OBSERVATION FAN ROTATION & RESISTANCE
GAIN ACCESS TO PCB
REMOVE FAN DRIVER PCB FROM THE FAN ASSEMBLY
VOLTAGE FAN
{GAINPCBACS}
REMOVE FAN DRIVER PCB FROM THE FAN ASSEMBLY & MAKE SAFE
INSPECTION WIRING HARNESS CONNECTIONS
GAIN ACCESS TO PCB
DISCONNECT EXTERNAL BL CONNECTIONS
REMOVE EXTERNAL CONN
TEMPERATURE DIFFERENTIAL DHW HEAT EXCHANGER
ATTACH A TEMPERATURE
System Information
- Total Tests: 496
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control