Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect HMI cable at the PCB
Gain access to User Interaction PCB ensuring that the
DHW temperature control is set to MAX 65°C

Measurement:

Test 1. Measure for resistance across the DHW temperature potentiometer at test point 1 as illustrated - Expected resistance 0 - 10 ohms.
Test 2. Measure for resistance across the DHW temperature potentiometer at test point 2 as illustrated - Expected resistance approximately 2.4 Kohms.