Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for AC voltage across resistor R115 (as illustrated) and a suitable earth connection.
Expected voltage approximately 98 volts AC.
Expected voltage approximately 98 volts AC.

Isolate as per TOPs P4
and refit as necessary