BIASI RIVA ADVANCE M110.24SM/C
WARNING - IMPORTA
BURNER IGNITES AND ESTABLISHES
SET DHW TEMPERATURE SELECTOR TO MAX
BIASI RIVA ADVANCE M110.24SM/C
47 970 29
1.
FAULT 2
GAS INLET PRESSURE
FAULT 1
ELECTRODE - DETECTION
FAULT 1
ELECTRICAL SAFETY CHECKS
FAULT 2
CONDENSATE TRAP
FAULT 2
HEAT EXCHANGER - CONDENSING
FAULT 2
FLUE
FAULT 6 SENSE AC
ELECTRONIC CONTROL - IGNITION
FAULT 1
EXPANSION VESSEL
FAULT 10 OVERRUN FUNCTION
ELECTRONIC CONTROL - IGNITION
FAULT 1
SERVICE KIT - DIVERTER VALVE
FAULT 1
TAP 1/2IN - DHW
FAULT 1 RESET
GAS INLET PRESSURE (HIGH)
FAULT 2
PUMP
FAULT 3A FAN CONTROL
ELECTRONIC CONTROL - IGNITION
FAULT 4
TEMPERATURE PROBE - DHW
FAULT 4
TEMPERATURE PROBE - DHW
FAULT 3C FAN CONTROL
ELECTRONIC CONTROL - IGNITION
FAULT 5
FAN
FAULT 6
FAN
FAULT 4
GAS INLET PRESSURE
FAULT 3
TEMPERATURE PROBE - DHW
FAULT 3
TEMPERATURE PROBE - DHW
FAULT 2
PROBE - FLUE TEMPERATURE
FAULT 3
VALVE - GAS
FAULT 4
PUMP
FAULT 1
GAS INLET PRESSURE
FAULT 5 GV VOLTAGE
ELECTRONIC CONTROL - IGNITION
FAULT 1
PUMP - DIVERTER VALVE CABLE
FAULT 2
VALVE - GAS
FAULT 3
GAS INLET PRESSURE
FAULT 3
PROBE - FLUE TEMPERATURE
FAULT 2
TEMPERATURE PROBE - DHW
FAULT 2
TEMPERATURE PROBE - DHW
FAULT 3G FAN CONTROL
ELECTRONIC CONTROL - IGNITION
FAULT
KIT - MICROSWITCH
FAULT 1
THERMOSTAT 105DEG C - OVERHEAT
FAULT 1
TEMPERATURE PROBE - DHW
FAULT 1
TEMPERATURE PROBE - DHW
FAULT 1
PROBE - FLUE TEMPERATURE
FAULT 1
CABLE - FAN
FAULT 7
FAN
FAULT 11B LOCKOUT RESET PCB
ELECTRONIC CONTROL - IGNITION
FAULT 4 IGNITON OUTPUT
ELECTRONIC CONTROL - IGNITION
FAULT 1
IGNITION ELECTRODES
FAULT 1
CONDENSATE TRAP
FAULT 1
HEAT EXCHANGER - CONDENSING
FAULT 1
FLUE
FAULT 1 MISSING DAMAGED
CABLE - EARTH - IGNITION ELECTRODE
FAULT 8A CH DEMAND VOLTAGE
ELECTRONIC CONTROL - IGNITION
FAULT 1
FUSE F1
FAULT 8 CH DEMAND 1
ELECTRONIC CONTROL - IGNITION
FAULT 9ADIVERTER VOLTS
ELECTRONIC CONTROL - IGNITION
FAULT 2
SERVICE KIT - DIVERTER VALVE
FAULT 3
PUMP
FAULT 9 DIVERTER VOLTS
ELECTRONIC CONTROL - IGNITION
FAULT 1
FUSE F1
FAULT 3
SERVICE KIT - DIVERTER VALVE
FAULT 1
KIT - BYPASS
FAULT 2
KIT - BYPASS
FAULT 1
FUSE F3
FAULT 1
TRANSFORMER
BURNER DOES NOT IGNITE
CABLE - FAN
FAULT 2 FAN SPEED DOES NOT INCREASE
TEMPERATURE PROBE - DHW
FAULT 2 FAN SPEED DOES NOT INCREASE
TEMPERATURE PROBE - DHW
FAULT 3 FAN SPEED DOES NOT INCREASE
PROBE - FLUE TEMPERATURE
FAULT 1
DIAPHRAGM - PRESSURE SWITCH CH
FAULT 1
KIT - FLOW GROUP
FAULT 2
BURNER
FAULT 7 SENSE DC
ELECTRONIC CONTROL - IGNITION
FAULT 1
KIT - FLOW GROUP
FAULT 1 NOISE
HEAT EXCHANGER - CONDENSING (FLUEWAYS)
FAULT 1
DHW INLET FILTER
FAULT 1
VALVE - GAS
FAULT 2
HEAT EXCHANGER - DHW
FAULT 1
FLOW LIMITER 10LTRS/MIN
FAULT 1
FLOAT FLOWSWITCH
FAULT 2A TEMP CONTROL
ELECTRONIC CONTROL - IGNITION
FAULT 3F FAN CONTROL
ELECTRONIC CONTROL - IGNITION
FAULT 4
HEAT EXCHANGER - DHW
FAULT 1
PUMP
FAULT 1
VALVE - GAS
FAULT 3
HEAT EXCHANGER - DHW
FAULT 1
FAN
FAULT 3 FAN OPERATION
ELECTRONIC CONTROL - IGNITION
FAULT 2
DHW INLET FILTER
FAULT 2
FLOW LIMITER 10LTRS/MIN
FAULT 2
FLOAT FLOWSWITCH
FAULT 1
FLOW SWITCH - DHW
FAULT 1
LOCK OUT RESET
FAULT 1
GENERATOR - SPARK
FAULT 1
BURNER
FAULT 1
SWITCH - TIMER - FLASH MONOTRON 200
FAULT 2
MOTOR - 3 WAY VALVE
FAULT 1
MOTOR - 3 WAY VALVE
FAULT 2
KIT - FLOW GROUP
FAULT 1 TX VOLTS
ELECTRONIC CONTROL - IGNITION
FAULT 2 DHW DEMAND
ELECTRONIC CONTROL - IGNITION
FAULT 2 FAN SPEED DOES NOT INCREASE
ELECTRONIC CONTROL - IGNITION
PRIMARY FLOW SWITCH BODY
KIT - FLOW GROUP
FAULT 1
HEAT EXCHANGER - DHW
RADS HOT DHW COOL
CHARACTERISTIC TEST FROM DHW OPERATION
DHW NOISY KETTLING
CHARACTERISTIC TEST FROM DHW OPERATION
RADS COLD DHW COOL
CHARACTERISTIC TEST FROM DHW OPERATION
DHW TOO HOT
CHARACTERISTIC TEST FROM DHW OPERATION
BOILER TO TEMP RADS COOL
CHARACTERISTIC TEST FROM CH OPERATION
BOILER COOL RADS COOL
CHARACTERISTIC TEST FROM CH OPERATION
BOILER NOISY DHW OK
CHARACTERISTIC TEST FROM CH OPERATION
DHW FLOW LIMITER BLOCKED OR DAMAGED
CHARACTERISTIC TEST FROM FLOW SWITCH ASSEMBLY
FLOAT DAMAGED
CHARACTERISTIC TEST FROM FLOW SWITCH ASSEMBLY
DHW FLOW LIMITER BLOCKED OR DAMAGED
CHARACTERISTIC TEST FROM FLOW SWITCH ASSEMBLY
FLOAT DAMAGED
CHARACTERISTIC TEST FROM FLOW SWITCH ASSEMBLY
FLOW SWITCH ASSEMBLY CLEAR
CHARACTERISTIC TEST FROM FLOW SWITCH ASSEMBLY
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
BURNER DOES NOT IGNITE
CHARACTERISTIC TEST FROM BURNER IGNITES AND ESTABLISHES
FLOW SWITCH ASSEMBLY CLEAR
CHARACTERISTIC TEST FROM FLOW SWITCH ASSEMBLY
29/08/2018 08:48:40 1807_1_50_1 20/09/2018 11:48:41
29/08/2018 08:54:12
SENSE ELECTRODE INSPECTION
REMOVE FLAME SENSE ELECTRODE
EXTERNAL CONTROLS OUTPUT
INTEGRAL PROGRAMMER ON
GAIN ACCESS TO APPLIANCE TERMINAL STRIP
FAN PRESSURE
FUNCTION SELECTOR IN
PUMP VOLTAGE
{GAINPCBACS}
FAN VOLTAGE
{GAINPCBACS}
FLOW SWITCH VOLTS
{GAINPCBACS}
GAS VALVE VOLTAGE
{GAINPCBACS}
HOT TAP ON
FUNCTION SELECTOR IN STANDBY POSITION
MAINS POWER SUPPLY
REMOVE CONTROL BOX COVER
FAN HARNESS RESISTANCE (CONTROL)
REMOVE BOTH ENDS OF THE FAN HARNESS, FROM THE PLUG AT THE FAN END AND FROM X22 ON THE PCB
MAINS POWER SUPPLY FUSE (FUSED SPUR)
REMOVE THE FUSE FROM THE FUSED SPUR
FLOW BLOCKAGE OR DAMAGE
DHW DISCHARGED AND D
SPARK GENERATOR INPUT
{GAINPCBACS}
FUNCTION SELECTOR IN STANDBY POSITION
EXTERNAL CONTROLS INPUT
INTEGRAL PROGRAMMER ON
DIVERTER VALVE VOLTAGE
{GAINPCBACS}
FUNCTION SELECTOR IN STANDBY POSITION
ALL CH CONTROLS CALLING
DIVERTER VALVE OPERATION
FUNCTION SELECTOR IN STANDBY POSITION
ALL CH CONTROLS CALLING
DIVERTER VALVE VOLTAGE
{GAINPCBACS}
FUNCTION SELECTOR IN STANDBY POSITION
ALL CH CONTROLS CALLING
INTEGRAL BYPASS INSPECTION
APPLIANCE DRAINED AND DISCHARGED
CH FLOW AND RETURN VALVES OFF
WATER OFF
INTEGRAL BYPASS INSPECTION
APPLIANCE DRAINED AND DISCHARGED
CH FLOW AND RETURN VALVES OFF
WATER OFF
FAN HARNESS RESISTANCE (CONTROL)
REMOVE BOTH ENDS OF THE FAN HARNESS, FROM THE PLUG AT THE FAN END AND FROM X22 ON THE PCB
FLOW SENSOR RESISTANCE
REMOVE THE LEAD FROM THE FLOW SENSOR
PRIMARY CIRCUIT FLOW SWITCH OPERATION
DHW TAP ON
PRIMARY CIRCUIT FLOW SWITCH DIAPHRAGM INSPECTION
WATER OFF
APPLIANCE DISCHARGED AND DRAINED
PCB FLAME SENSE VOLTAGE AC
{GAINPCBACS}
REMOVE THE FLAME SENSE LEAD FROM CONNECTION MARKED
X15 ON THE PCB
FLAME SENSE VOLTAGE DC
FUNCTION SELECTOR IN
PRIMARY FLUE WAYS
REMOVE BURNER ASSEMBLY
DIVERTER VALVE MOTOR POSITION
REMOVE DIVERTER VALVE MOTOR
FLOW BLOCKAGE OR DAMAGE
DHW DISCHARGED AND D
DIVERTER VALVE SPINDLE
REMOVE THE DIVERTER VALVE ACTUATOR FROM THE DIVERTER VALVE BODY
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
SET DHW TEMPERATURE SELECTOR TO MAX
GAS ON
FLOW SENSOR RESISTANCE
REMOVE THE LEAD FROM THE FLOW SENSOR
THERMISTOR DHW RESISTANCE
REMOVE THE LEAD FROM THE DHW SENSOR
FAN SPEED
FUNCTION SELECTOR IN STANDBY POSITION
HOT TAP ON
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
SET DHW TEMPERATURE SELECTOR TO MAX
GAS ON
FAN RESISTANCE
DISCONNECT FAN CONNECTOR (X22) FROM THE PCB
FAN MECHANICAL CHECK
REMOVE FAN
FLOW SENSOR RESISTANCE
REMOVE THE LEAD FROM THE FLOW SENSOR
THERMISTOR DHW RESISTANCE
REMOVE THE LEAD FROM THE DHW SENSOR
HARNESS RESISTANCE - PUMP
DISCONNECT PUMP LEAD FROM PUMP
DISCONNECT CONNECTOR MARKED X12 FROM THE PCB
FLUE SENSOR RESISTANCE
DISCONNECT THE BROWN AND BLUE LEADS AT THE INLINE CONNECTORS FROM THE FLUE TEMPERATURE THERMOSTAT
BYPASS INTEGRAL
FUNCTION SELECTOR IN CH POSITION
CH DEMAND
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
SET DHW TEMPERATURE SELECTOR TO MAX
GAS ON
FAN PRESSURE TEST
FUNCTION SELECTOR IN
FLOW SWITCH OPERATION
{GAINPCBACS}
FAN SPEED
FUNCTION SELECTOR IN STANDBY POSITION
HOT TAP ON
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
SET DHW TEMPERATURE SELECTOR TO MAX
GAS ON
FLOW SENSOR RESISTANCE
REMOVE THE LEAD FROM THE FLOW SENSOR
THERMISTOR DHW RESISTANCE
REMOVE THE LEAD FROM THE DHW SENSOR
FLUE SENSOR RESISTANCE
DISCONNECT THE BROWN AND BLUE LEADS AT THE INLINE CONNECTORS FROM THE FLUE TEMPERATURE THERMOSTAT
OVERHEAT THERMOSTAT RESISTANCE
DISCONNECT ONE OF THE GREY LEADS FROM THE OVERHEAT THERMOSTAT
FLOW SENSOR RESISTANCE
REMOVE THE LEAD FROM THE FLOW SENSOR
THERMISTOR DHW RESISTANCE
REMOVE THE LEAD FROM THE DHW SENSOR
FLUE SENSOR RESISTANCE
DISCONNECT THE BROWN AND BLUE LEADS AT THE INLINE CONNECTORS FROM THE FLUE TEMPERATURE THERMOSTAT
FUSE F1
REMOVE THE COVER TO THE PCB WHICH IS ACCESSIBLE FROM THE LOWERED CONTROL PANEL
FAN RESISTANCE
DISCONNECT FAN CONNECTOR (X22) FROM THE PCB
FAN MECHANICAL CHECK
REMOVE FAN
SPARK GENERATOR EARTH LEAD
REMOVE THE SPARK LEAD FROM THE SPARK GENERATOR
FUNCTION SELECTOR IN STANDBY POSITION
SPARK GENERATOR OUTPUT
REMOVE THE SPARK LEAD FROM THE SPARK GENERATOR
FUNCTION SELECTOR IN STANDBY POSITION
SENSE ELECTRODE INSPECTION
REMOVE SPARK ELECTRODE
PRIMARY FLUE WAYS
REMOVE BURNER ASSEMBLY
FUSE F2
REMOVE THE COVER TO THE PCB WHICH IS ACCESSIBLE FROM THE LOWERED CONTROL PANEL
INTEGRAL PROGRAMMER
DISCONNECT CONNECTOR MARKED X2 FROM THE PCB
DIVERTER VALVE MOTOR POSITION CH
FUNCTION SELECTOR IN CH POSITION
ALL HEATING CONTROLS CALLING
DIVERTER VALVE SPINDLE
REMOVE THE DIVERTER VALVE ACTUATOR FROM THE DIVERTER VALVE BODY
FUSE F3
REMOVE THE COVER TO THE PCB WHICH IS ACCESSIBLE FROM THE LOWERED CONTROL PANEL
BYPASS INTEGRAL
FUNCTION SELECTOR IN CH POSITION
CH DEMAND
DIVERTER VALVE SPINDLE
REMOVE THE DIVERTER VALVE ACTUATOR FROM THE DIVERTER VALVE BODY
THERMISTOR DHW RESISTANCE
REMOVE THE LEAD FROM THE DHW SENSOR
FLUE SENSOR RESISTANCE
DISCONNECT THE BROWN AND BLUE LEADS AT THE INLINE CONNECTORS FROM THE FLUE TEMPERATURE THERMOSTAT
PRIMARY CIRCUIT FLOW SWITCH TOP COVER AND SPINDLE INSPECTION
APPLIANCE DRAINED AND DISCHARGED
WATER OFF
FAN VOLTAGE
{GAINPCBACS}
GAS INLET PRESSURE
ATTACH PRESSURE GAUGE TO INLET PRESSURE TEST POINT
SET DHW TEMPERATURE SELECTOR TO MAX
GAS ON
System Information
- Total Tests: 228
- Sequence Logic: Decoded from encrypted .seq file
- Navigation: Dynamic based on pass/fail results
- Source: 4731307 GW SWIFTFLOW 100 SIT Control