Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Hot tap ON
Function selector in standby position
Hot tap ON
Function selector in standby position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Function selector to DHW position.
Allow fan to start.
After approximately 5 seconds measure voltage across the blue (neutral) and brown (live) leads on connector marked X17 on the PCB.
Expected voltage mains voltage (240 VAC).
Voltage will only be present for approximately 4 seconds as flame will not prove.
Allow fan to start.
After approximately 5 seconds measure voltage across the blue (neutral) and brown (live) leads on connector marked X17 on the PCB.
Expected voltage mains voltage (240 VAC).
Voltage will only be present for approximately 4 seconds as flame will not prove.

Isolate as per TOPs P4
and refit as necessary