Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Function selector in standby position
All CH controls calling
Function selector in standby position
All CH controls calling
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Switch function selector in the CH position.
Measure voltage across the black lead (neutral) and the red lead (live), on connector marked X12 on the PCB.
Expected voltage Mains voltage (230 VAC).
Switch the function selector back to stand by position.
Measure voltage across the black lead (neutral) and the and the white lead (live), on connector marked X12 on the PCB.
Expected voltage Mains voltage (230 VAC).
Measure voltage across the black lead (neutral) and the red lead (live), on connector marked X12 on the PCB.
Expected voltage Mains voltage (230 VAC).
Switch the function selector back to stand by position.
Measure voltage across the black lead (neutral) and the and the white lead (live), on connector marked X12 on the PCB.
Expected voltage Mains voltage (230 VAC).

Isolate as per TOPs P4
and refit as necessary