4758137 RAVENHEAT CSI 120(T) UPTO SERIAL NUMBER 16007132
REMOVAL OF FR
DHW FAN RUNS
DHW SELECTOR IN MAXI
DHW BURNER IGNITES AND ESTABLISHES (GAS PRESSURE)
ATTACH PRESSURE GAUG
POWER UP
{ALLDEMANDOFF}
BO
INFORMATION APPLIANCE VERSION
THIS MODEL IS ONLY A
F17 FAN FAULT
INTENTIONALLY BLANK - HEADER FOR FAULT CODE
THE OTHER FAULT CODES ARE AT THE TOP OF MODEL - NOT SURE WHY
INTENTIONALLY BLANK - HEADER FOR FAULT CODE
F14 FLAME SIMULATION ON THE FLAME CONTROL UNIT
INTENTIONALLY BLANK - HEADER FOR FAULT CODE
F4 OVERHEAT
INTENTIONALLY BLANK - HEADER FOR FAULT CODE
HEADER FOR QADAI GAS VALVE RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI PUMP VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI FAN VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI CH SENSOR
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI HW SENSOR
INTENTIONALLY BLANK - HEADER FOR QADAI
LITE DIAGNOSTIC
DIAGNOSIS RELIES ON
QUICK ACCESS DATA AND INFORMATION
THE TABLE BELOW SHOW
HEADER FOR QADAI PUMP RESISTANCE
INTENTIONALLY BLANK - HEADER FOR QADAI
HEADER FOR QADAI GAS VALVE VOLTAGE
INTENTIONALLY BLANK - HEADER FOR QADAI
DHW SPARKING
FLUE
POWER UP
MAINS FUSE
PIN STUCK
DHW MICROSWITCH
QADAI
GAS VALVE
QADAI
CH SENSOR
QADAI
DHW SENSOR
BLANK FOR LITE DIAGNOSTIC
Z DIRECTION
BLANK FOR QADAI
Z DIRECTION
NOT ACTIVATING FLOW SWITCH
DIVERTER VALVE - 3 WAY VALVE
QADAI 2
PUMP
QADAI
IGNITION CONTROL BOARD
DHW OPERATION
CONDENSATE TRAP
DHW OPERATION
FLUE
CH OPERATION
CH SENSOR
BOILER HEATS BUT RADS COLD
DIVERTER VALVE - 3 WAY VALVE
SYSTEM PRESSURE RISE
EXPANSION VESSEL
START
START
PUMP OVERRUN
PCB
BURNER IGNITION
OVERHEAT THERMOSTAT
POWER UP
FUSE F1 3.15A
POWER UP
ON/OFF SWITCH
POWER UP
TRANSFORMER
POWER UP
HARNESS FAN
IGNITION
PCB
NOT LIGHTING
HARNESS IGNITION PCB LOW VOLTAGE
NOT LIGHTING
CSI120 BURNER
BURNER IGNITES (NO IGNITION)
CONDENSATE TRAP
FAN RUNNING CONT ON DEMAND
HARNESS IGNITION PCB LOW VOLTAGE
NOT LIGHTING
PCB
CH POT
CH POTENTIOMETER
PUMP RUNS
SUMMER/WINTER SWITCH
DHW NOISY OPERATION KETTLES
SECONDARY (DHW) HEAT EXCHANGER
DHW OPERATION
DIVERTER VALVE - 3 WAY VALVE
OPS PAGE
DUMMY
FAULT FAIL
DUMMY
PROC
DUMMY
FAULT CODE 06
DHW SENSOR
PUMP RUNS
SYSTEM PRESSURE
DHW SPARKING
SPARK ELECTRODES
DOES NOT IGNITE
CABLE - SPARK ELECTRODE
NOT LIGHTING
PRIMARY HEAT EXCHANGER CSI120
DV PUMP RUNS
PCB
DHW OPERATION
CH SENSOR
DHW OPERATION
CSI120 BURNER
COLD TAP PASSING - DHW COLD
EXTERNAL HOT WATER FAULT
DHW OPERATION
DHW SENSOR
DHW OPERATION
GAS INLET PRESSURE
FAULT CODE 12
CH SENSOR
RUNNING NON STOP
HARNESS FAN
FIRING WITH NO DEMAND
FLOW SWITCH - 3 WAY VALVE MICROSWITCH
GAS PRESSURES INCORRECT
IGNITION CONTROL BOARD
GAS VALVE (GAS PRESSURES INCORRECT)
HARNESS IGNITION
DHW BURNER IGNITES (ELECTRICAL)
GAS VALVE
BURNER IGNITES (ESTABLISH)
CONDENSATE TRAP
DOES NOT ESTABLISH
CABLE FLAME SENSE
DHW FLOW RATE FAIL
DUMMY
LOCKOUT RESET
HARNESS PCB TO DISPLAY
FAULT CODE RESET
DUMMY
FAULT CODE 28
PCB
NOT SWITCHING
TIMER - DIGITAL
FIRING NO DEMAND
CH SENSOR
FAN RUNS NO DEMAND
SUMMER/WINTER SWITCH
INFORMATION PCB LINK
DUMMY
POWER UP
FUSE 315 MILLIAMP
INFO
DUMMY
F17 - NO FAN
HARNESS FAN
F17 - FAN RUNS
HARNESS FAN
DHW FLOW RATE
DHW ISOLATING VALVE
F17 - FAN RUNS
FAN ASSEMBLY
DHW FAN RUNS
FAN ASSEMBLY
DHW FAN RUNS
HARNESS FAN
FAN RUNS
CH SENSOR
FAN RUNS
DHW SENSOR
DHW POT
DHW POTENTIOMETER
DHW TOO HOTFAN RUNS
DHW SENSOR
DHW TOO HOT
DHW POTENTIOMETER
F14
PCB
F14
CABLE FLAME SENSE
F14
ELECTRODE - SENSING
F14
CONDENSATE TRAP
F14 DHW BURNER IGNITES
CSI120 BURNER
F14
MAIN HEAT EXCHANGER
F14
FLUE
FLUEWAYS RESTRICTED - DHW
MAIN HEAT EXCHANGER
F28 NO FLUE STAT
HARNESS LOW VOLTAGE
FAULT CODE 28
FLUE THERMOSTAT
FAULT CODE 28
FUSE - THERMAL
F4
CH SENSOR
F4
DHW SENSOR
F4
PCB
WORN NIPPLE
DHW MICROSWITCH
GAS VALVE
RESULT AS EXPECTED
VOLTAGE PUMP AT PCB
RESULT AS EXPECTED
VOLTAGE FAN AT PCB
RESULT AS EXPECTED
RESISTANCE CH SENSOR
RESULT AS EXPECTED
RESISTANCE HW SENSOR
RESULT AS EXPECTED
RESISTANCE PUMP
RESULT AS EXPECTED
VOLTAGE GAS VALVE AT PCB
RESULT AS EXPECTED
DHW FLOW RATE
DHW INLET FILTER
DHW OPERATION
FAN ASSEMBLY
BLOCKED
DIVERTER VALVE - 3 WAY VALVE
OVERHEAT STAT
HARNESS LOW VOLTAGE
PCB TO IGNITION PCB (FAN RUNS CONTINUOUSLY)
HARNESS IGNITION
POWER UP
FAN ASSEMBLY
NOT LIGHTING
GAS INLET PRESSURE
DOES NOT IGNITE
IGNITION CONTROL BOARD
PCB TO IGNITION PCB (PRESSURES CORRECT)
HARNESS IGNITION
FAN RUNS CONTINUOUSLY
IGNITION CONTROL BOARD
OPERATION
TIMER - DIGITAL
DHW OPERATION
PRIMARY HEAT EXCHANGER CSI120
DHW COLD RADS HOT
SECONDARY (DHW) HEAT EXCHANGER
OPS PAGE PASS
DUMMY
FAULT PASS
DUMMY
FAULT CODE 06
PCB
FAULT CODE 06
HARNESS LOW VOLTAGE
NO INLET PRESSURE
GAS INLET PRESSURE
NOT LIGHTING
FLUE
DHW PUMP RUNS
PUMP
DHW COLD RADIATORS COLD
SECONDARY (DHW) HEAT EXCHANGER
DHW SENSOR HW/RADS COLD
HARNESS LOW VOLTAGE
CH SENSOR HW/RADS COLD
HARNESS LOW VOLTAGE
FAULT CODE 12
PCB
FAULT CODE 12
HARNESS LOW VOLTAGE
OVER HEATING
PUMP
DHW BURNER IGNITES (MECHANICAL)
GAS VALVE
DROPPING OUT AFTER IGN
GAS INLET PRESSURE
DROPS OUT INLET TOO LOW
GAS INLET PRESSURE
DHW FLOW RATE PASS
DUMMY
LOCKOUT RESET MECHANICAL
DIGITAL DISPLAY BOARD
LOCKOUT RESET
PCB
F28FIREUP
FLUE THERMOSTAT
POWER UP
PCB
F17 - NO FAN
FAN ASSEMBLY
CH SENSOR FAN RUNS
HARNESS LOW VOLTAGE
DHW SENSOR FAN RUNS
HARNESS LOW VOLTAGE
DHW FAN RUNS
PCB
DHW TOO HOT DHW SENSOR
HARNESS LOW VOLTAGE
DHW TOO HOT
PCB
SCALED
SECONDARY (DHW) HEAT EXCHANGER
F14
IGNITION CONTROL BOARD
DHW BURNER IGNITES
CSI120 BURNER
DHW BURNER ESTABLISHED (FLAME SENSE)
ELECTRODE - SENSING
DHW BURNER ESTABLISHED (FLAME SENSE)
IGNITION CONTROL BOARD
F28 - FLUE THERMISTOR
PRESSURE SWITCH - LOW WATER
F28 - THERMAL FUSE
PRESSURE SWITCH - LOW WATER
F28 - FLUE STAT
PRESSURE SWITCH - LOW WATER
F4
DUMMY
DHW INLET FILTER BLOCKED
CHARACTERISTIC TEST FROM DIVERTER VALVE AND DHW FILTER
DHW COLD, RADIATORS COLD
CHARACTERISTIC TEST FROM DHW OPERATION
DHW COLD, RADIATORS HOT
CHARACTERISTIC TEST FROM DHW OPERATION
DHW NOISY OPERATION, KETTLES
CHARACTERISTIC TEST FROM DHW OPERATION
BURNER BAFFLES OUT
CHARACTERISTIC TEST FROM DHW OPERATION
DIVERTER VALVE BLOCKED
CHARACTERISTIC TEST FROM DIVERTER VALVE AND DHW FILTER
BOILER HEATS, BUT RADS COLD
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
CH NOISY, DHW OK
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
APPLIANCE DOES NOT RUN ON CH
CHARACTERISTIC TEST FROM CENTRAL HEATING OPERATION
FAN DOES NOT KICK
CHARACTERISTIC TEST FROM POWER UP
FAN RUNS AT FULL SPEED ON POWER UP
CHARACTERISTIC TEST FROM POWER UP
BURNER DOES NOT LIGHT AND FAN STOPS
CHARACTERISTIC TEST FROM DHW BURNER IGNITES AND ESTABLISHES (GAS PRESSURE)
PRESSURE DROPS AWAY COMPLETELY
CHARACTERISTIC TEST FROM GAS INLET PRESSURE (BLIP)
DROP NOT OBSERVED
CHARACTERISTIC TEST FROM GAS INLET PRESSURE (BLIP)
STANDING PRESSURE INCORRECT OR ABSENT
CHARACTERISTIC TEST FROM GAS INLET PRESSURE (BLIP)
LIGHT ON FRONT PANEL BUT PUMP NOT RUNNING
CHARACTERISTIC TEST FROM DHW PUMP RUNS
NO LIGHT AND PUMP NOT RUNNING
CHARACTERISTIC TEST FROM DHW PUMP RUNS
PRESSURE DROPS AWAY COMPLETELY
CHARACTERISTIC TEST FROM GAS INLET PRESSURE (BLIP)
STANDING PRESSURE INCORRECT OR ABSENT
CHARACTERISTIC TEST FROM GAS INLET PRESSURE (BLIP)
FAN RUNS CONTINUOUSLY WITH NO LOCKOUT
CHARACTERISTIC TEST FROM DHW BURNER IGNITES AND ESTABLISHES (GAS PRESSURE)
BURNER IGNITES BUT DOES NOT ESTABLISH
CHARACTERISTIC TEST FROM DHW BURNER IGNITES AND ESTABLISHES (GAS PRESSURE)
FAN DOES NOT RUN
CHARACTERISTIC TEST FROM DHW FAN RUNS
FAN RUNS FOR APPROXIMATELY 5 SECONDS THEN STOPS
CHARACTERISTIC TEST FROM DHW FAN RUNS
DHW TOO HOT
CHARACTERISTIC TEST FROM DHW OPERATION
BURNER CHECKS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER AND SENSE ELECTRODE
ELECTRODE CHECKS UNSATISFACTORY
CHARACTERISTIC TEST FROM INSPECTION BURNER AND SENSE ELECTRODE
THERMAL FUSE FITTED
CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF FLUE PROTECTION
FLUE THERMISTOR FITTED
CHARACTERISTIC TEST FROM OBSERVATION WHAT TYPE OF FLUE PROTECTION
10/03/2023 09:08:01 2211_3_50_1 21/06/2023 13:21:14
10/03/2023 11:44:55
RESISTANCE MAINS FUSE
REMOVE THE FUSE FROM THE FUSED SPUR
RESISTANCE DHW MICROSWITCH
GAIN ACCESS TO PCB (
GAS VALVE SOLENOID RESISTANCE
REMOVE THE PLUG FROM THE GAS VALVE
DHW PUMP VOLTAGE
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
FAN VOLTS FROM PCB
{ALLDEMANDOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
CH SENSOR RESISTANCE
REMOVE THE LEADS FROM THE CH SENSOR
DHW SENSOR RESISTANCE
REMOVE THE LEADS FROM THE DHW SENSOR
RESISTANCE PUMP AND HARNESS
GAIN ACCESS TO PCB AND REMOVE CONNECTOR JP6
OVERHEAT THERMOSTAT RESISTANCE
DISCONNECT BROWN & BLUE LEADS FROM THE OVERHEAT THERMOSTAT
MAINS POWER TO CLOCK
GAIN ACCESS TO CLOCK CONNECTIONS (USE INSULATION MAT AS NECESSARY)
SUMMER/ WINTER SWITCH OPERATION
REMOVE 1 CONNECTOR FROM THE RIGHT HAND SWITCH (PINK LEADS)
OPERATIONAL SEQUENCE
NO LONGER USED
HARNESS & DHW SENSOR RESISTANCE
REMOVE THE PLUG JP11 FROM THE CONTROL BOX
DHW SENSOR RESISTANCE
REMOVE THE LEADS FROM THE DHW SENSOR
CH SENSOR RESISTANCE
REMOVE THE LEADS FROM THE CH SENSOR
DHW SENSOR RESISTANCE
REMOVE THE LEADS FROM THE DHW SENSOR
CH SENSOR RESISTANCE
REMOVE THE LEADS FROM THE CH SENSOR
DHW PUMP VOLTAGE
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
DISPLAY PCB HARNESS
REMOVE THE HARNESS F
OBSERVATION DOES FAN RUN
{ALLDEMANDOFF}
BO
FAN VOLTS FROM PCB
{ALLDEMANDOFF}
GAIN ACCESS TO PCB (USE INSULATION MAT AS NECESSARY)
CH SENSOR RESISTANCE
REMOVE THE LEADS FROM THE CH SENSOR
DHW SENSOR RESISTANCE
REMOVE THE LEADS FROM THE DHW SENSOR
DHW SENSOR RESISTANCE
REMOVE THE LEADS FROM THE DHW SENSOR
OBSERVATION DISCONNECT IGNITION PCB
DISCONNECT 7 PIN PLUG FROM IGNITION PCB AND MAKE SAFE
RESISTANCE WATER PRESSURE SWITCH HARNESS
DISCONNECT PLUG CONN
CH SENSOR RESISTANCE
REMOVE THE LEADS FROM THE CH SENSOR
INSPECTION DIVERTER MOVEMENT
REMOVE THE MICROSWITCH FROM THE TOP OF THE DIVERTER VALVE AND PLACE IN A SAFE POSITION.
OBSERVATION DISCONNECT DHW MICROSWITCH
REMOVE THE DHW MICRO
DIFFERENTIAL TEMPERATURE (HEATING)
ATTACH TEMPERATURE CLAMPS TO FLOW AND RETURN PIPES
GAS INLET PRESSURE
ATTACH U-GAUGE TO THE INLET PRESSURE TEST POINT
CH SENSOR RESISTANCE
REMOVE THE LEADS FROM THE CH SENSOR