Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Disconnect 7 pin plug from ignition PCB and make safe
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance.
With the ignition PCB disconnected does the error code 14 reoccur?