Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Observation:
Undo the gas large connection below gas valve, the 6 nuts around the edge of the burner door and carefully remove the burner assembly from the boiler.
Inspect Electrode assembly for signs of damage.
Before refitting the burner assembly check the seal is in good condition and replace if needed.
Inspect Electrode assembly for signs of damage.
Before refitting the burner assembly check the seal is in good condition and replace if needed.
Isolate as per TOPs P4
and refit as necessary